BAYROL 150200 AutomaticCl-pH Wi-Fi Metering Pump Instruction Manual
- June 13, 2024
- BAYROL
Table of Contents
- Introduction
- Scope of delivery
- Water values
- Tools needed for Installation (not included)
- Installation scheme
- Electrical installation scheme
- Cutting the hoses
- Injection valve installation
- Connection of the hoses to the dosing pumps
- Sensor installation
- Electrical connections on the device
- Commissioning
- Operation
- Additionals options
- Winterizing
- Maintenance
- Technical data
- Declaration of Conformity
- Disposal instructions
- Safety instructions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BAYROL 150200 AutomaticCl-pH Wi-Fi Metering Pump Instruction Manual
Introduction
Congratulations on the purchase of your AutomaticCl-pH. You have thus chosen
the easiest way to perfectly maintained pool water.
Please be sure to read the “Safety instructions” supplement!
IMPORTANT: The AutomaticCl-pH must be installed by an experienced pool dealer to ensure proper functioning!
- Please read these instructions carefully and make sure that all necessary parts for installation as well as all required tools are at hand.
- Failure to comply with these instructions may result in health and/or equipment and installation hazards!
- Only use BAYROL water care products!
- The housing of the AutomaticCl-pH does not have to be opened for installation.
- Be sure to observe all general and special hazard warnings when handling liquid water care products.
- Also observe all generally applicable safety regulations. Wear protective clothing if necessary.
Scope of delivery
- Automatic Cl-pH
- Pressure hose, 2 pcs
- Suction hose, 2 pcs
- Canister lid with hole for suction hose, 2 pcs
- Saddle clamp Ø 50 mm, 4 pcs
- Wall mounting set
- Feed filter, 2 pcs
- Sensor holder, 2 pcs
- Injection valve, 2 pcs
- pH sensor
- Redox sensor
- Cleaning solution for sensor
- Buffer solution pH 7
- Buffer solution redox 465 mV
- Teflon tape
Water values
| Alkalinität/TAC (mg/l)| pH Wert (pH)| Chlor DPD1 (mg/l)
---|---|---|---
Recommended values| Min. 80| 7.2| 0.6 – 1.0
Tolerated values| Min. 80| 7.0 – 7.4| 0.5 – 1.5
To lift| AddBAYROL Alca-Plus®| AddpH-Plus Liquid| Increase dosing
quantity, Add chlorine manually
To lower| –| AddpH-Minus Liquid Domestic| Reduce dosing quantity; Carry
out backwashing; use chlorine neutralizer (please ask your local pool
professional)
Test during season| monthly| weekly| weekly
Please be sure to adjust the pH value to the recommended value before adding
chlorine!
If the pool is filled with fresh water from the tap, it is recommended to pre-
treat the pool water with a chlorine shock.
IMPORTANT: After this initial chlorine shock, it is essential to wait until the chlorine value has decreased to the desired chlorine value (0.6 – 1.0 mg/l) before starting the AutomaticCL-pH.
Tools needed for Installation (not included)
Installation scheme
IMPORTANT:
The injection of pH-Minus Liquid Domestic or pH-Plus Liquid and Chloriliquide
must be the last component of the installation before flowing into the pool.
Make sure that the pressure in the circulation line does not exceed 1.0 bar!
We recommend using the convenient BAYROL Smart & Easy Connector with the
additional flow monitoring.
Electrical installation scheme
IMPORTANT:
The electrical installation of the AutomaticCl-pHmust be done by an
electrician.
- Residual Current Protective Device (RCD) ≤ 30 mA
- Filter control respectively time switch
- Power supply for dosing pumps (voltage only when circulation pump is running)
Cutting the hoses
Saddle clamp installation
IMPORTANT: respect mounting position
Sensor
Injection valve
We recommend the use of the convenient BAYROL Smart &Easy Connector
Injection valve installation
Connection of the hoses to the dosing pumps
Sensor installation
Electrical connections on the device
- Level pH – for optional suction lance
- pH sensor
- Flow sensor – for optional paddle switch
- USB port (updates via USB-stick)
- Temperature – for optional Temperature
- Redox sensor
- Level Cl – for optional suction lance
- Power supply for dosing pump
- Power cable
Commissioning
As soon as the water values are set and your device is installed with all
components, you can start commissioning the AutomaticCl-pH.
Switch on the AutomaticCl-pH and follow the instructions on the display. You
will be guided through the initial setup wizard, which will help you with the
essential settings. Of course, you can also access all the settings you have
made later and adjust them if necessary. As soon as the individual steps are
completed, the AutomaticCl-pH starts operation.
Operation
Tap in the blue frame areas to access the respective context menus.
Access codes
User Code| Service Code
1234| 5678
Status-Icons pH
Status-Icons Cl
Operating mode
Operating mode
Indicator dosing pump pH
Indicator dosing pump Cl
Fill level canister pH (red, when empty) Fill
level canister Cl (red, when empty)
Disinfection operating modes (chlorine)
Auto| Auto The AutomaticCl-pH automatically regulates the Chloriliquide
depending on the desired Redox-value in the pool
Off| Off The automatic control of the disinfection is switched off.
Timer functions Disinfection (chlorine)
|
Time| Time limited dosage The chlorine dosing can be switched on for a
selectable period of time. You can choose whether the chlorine dosing should
stop when the setpoint is reached or only after the selected time has elapsed.
You can stop the dosing manually at any time.
Pausing| Pausing the disinfection control The automatic control of
disinfection can be stopped for an adjustable period of time. After this
pause, the previously set control mode re-starts automatically. This mode can
be advantageous, for example, when adding water care products manually.
Operating modes pH value
Auto| Auto The AutomaticCl-pH automatically doses pH-Minus Liquid
Domestic (or pH-Plus Liquid) depending on the desired pH value in the pool.
Off| Off The automatic pH control is switched off
Timer functions pH value
| Fill and/or flush pump hoses In the event that the pH dosing hose is empty
(e.g. when changing canisters), you can start the pH-pump manually here to
fill the hose. Stop the process as soon as the dosing hose is completely
filled (i.e. up to the injection piece). Another menu helps you to rinse the
dosing hose (e.g. when winterizing the tank).
Time| Time limited dosage The pH pump can be switched on for a
selectable period of time. You can choose whether the pH dosing should stop
when the desired value is reached or only after the selected time has elapsed.
You can stop the dosing manually at any time.
Pausing| Pausing the pH regulation The automatic control of the pH-value
can be stopped for an adjustable period of time. After this pause, the
previously set regulation starts again automatically. This mode can be
advantageous, for example, when adding water care products manually.
Message list
All messages are listed in the message list. Additional information is
displayed here for each message. In addition, AutomaticCl-pH offers wizards
for most messages that will guide you step by step to the solution.
If the problem cannot be solved despite following all the instructions, please
contact your dealer.
Calibration – adjustment of the measured values
Please note that you must remove the sensors from their holders when
calibrating the pH- and redox-sensors using the buffer solutions provided.
Make sure that not too much water can escape during this process.
Follow the instructions on the display.
RECOMMENDATION
To avoid taking out the sensors, you can perform the calibration with the
pool water.
Please measure the pool water values with a photometer (e.g. BAYROL
Electronic Pooltester).
REMOTE ACCESS
To set up convenient remote access to your AutomaticCl-pH, please proceed as
follows:
-
Create a user account at www.bayrol-poolaccess.com
-
Register your AutomaticCl-pH in your user account. You will need the serial number of your device, which you will find on the type plate on the side of the housing.
-
You will be shown a 6-digit web portal PIN. Please make a note of this PIN, it must be entered once later in your device.
-
Now tap on the WiFi icon in the home screen of your AutomaticCl-pH and connect it to the desired WLAN in the „WLAN (WiFi) Connection“ menu.
-
Now connect your AutomaticCl-pH to the web portal by entering the previously noted web portal PIN in the „App & web portal connection“ menu.
Now your AutomaticCl-pH is visible in your previously created user account and can be operated from the web portal. -
If you would also like to operate your AutomaticCl-pH conveniently via app on your smartphone, please proceed as follows:
-
In the device list of the web portal: Press app link button
A QR code with URL (https://bayrol-poolaccess …) will now be displayed to you
-
Please note the App Link Code displayed, it will be used later to enter it in the app.
-
You have called up the webportal on your PC: Scan the QR-Code with your Smartphone or enter the URL in the Smartphone-Browser.
-
You have called up the webportal on your Smartphone: Simply tap directly on the URL.
You are using a smartphone with Android operating system:-
You are using a smartphone with Android operating system:
-
Tap the „Add to Home Screen“ button to install the app.
-
In the „Install App“ dialog, confirm the installation. | You are using a smartphone
with iOS operating system: -
Tap the icon („Share“) and select the „To Home Screen“ option.
-
In the „To Home Screen“ dialog, select the „Add“ option
---|---
-
-
Now the app is installed. Close the browser of your smartphone and launch the app from the home screen. When the app is started for the first time, a short guided sequence is run through. In this sequence, the app is linked to your AutomaticCl-pH by entering the app link code.
Additionals options
KIT Smart &Easy Connector Flow – Flow monitoring
The optionally available KIT Smart&Easy Connector Flow allows you to use the
sensors for pH and ORP, as well as the injection valves for pH-Minus Liquid
Domestic (pH-Plus Liquid) and Chloriliquide in a particularly convenient and
easy-to-maintain location. The Smart&Easy Connector also includes an
integrated paddle flow switch, which is connected to the AutomaticCl-pH by
means of a simple plug-in connection.
KIT Level Automatic Double – Canister monitoring
The optionally available KIT Level Automatic Double enables direct monitoring
of the fill level of the canisters for pH-Minus Liquid Domestic or pH-Plus
Liquid and Chloriliquide by means of two easy-to-handle suction lances. When
the canister is empty, a message is shown on the display. The KIT replaces the
supplied foot filters and can thus be easily connected to the intended Level
pH and Level Cl connection and mounted on the corresponding liquid containers
with the help of a screw cap.
KIT Temperatur Automatic – Temperature monitoring
With the optionally available KIT Temperature Automatic it is possible to
measure the temperature of the pool water.
The temperature sensor can be integrated into the circulation system at a
suitable point for temperature measurement by means of its supplied tapping
clamp.
Winterizing
In colder temperatures, it is recommended to take the AutomaticCl-pH out of
operation (e.g. during the winter period).
The following instructions show you how to winterise your pool:
In case of active winterizing (pool filter system remains in operation)
- Stop the filter pump.
- Rinse the pump hoses with clear water.
- Empty the pump hoses.
- Remove the sensors from their holders and store them in their container, which is preferably filled with KCl solution or also with clean pool water. Store the sensors in a dry and cool but frost-free place.
- Insert ½” plugs instead of the sensor holders.
- Store the canisters for pH-Minus Liquid Domestic or pH-Plus Liquid and Chloriliquide in a dry and cool but frost-free place.
In case of passive wintering (filter system of the pool is switched off).
- Stop the filter pump.
- Rinse the pump hoses with clear water.
- Empty all pump hoses.
- Close and empty the filter system. Make sure that the entire pool circulation system is drained as much as possible.
- Remove the sensors from their holders and store them in their container, which is preferably filled with KCl solution or also with clean pool water. Store the sensors in a dry and cool, but frost-free place.
- Store the canisters for pH-Minus Liquid Domestic or pH-Plus Liquid and Chloriliquide in a dry and cool but frost-free place.
Maintenance
The indicated amount of maintenance is just the minimum requirement. The frequency of maintenance depends on the intensity of use.
The frequency of maintenance is determined by the applicable, country-specific requirements! This may result in considerably shorter maintenance intervals; the relevant country-specific specifications and standards must be observed.
Note:
Only use original BAYROL Technik components. The use of third-party components
can lead to malfunction during operation. BAYROL Deutschland GmbH disclaims
all liability and warranty for this.
MAINTENANCE PLAN
Weekly check:
- Make sure you keep your filter system in perfect condition.
- Check the values for pH and chlorine, preferably with a
BAYROL Technik Electronic Pool Tester.
- Carry out a visual inspection of the system for leaks in all components, lines and hoses. Annual maintenance:
- Replace the pH sensor and calibrate it.
- Replace the Redox-sensor and set the correct setpoint mV. Make sure that the chlorine level in the pool water is at the desired level.
- Replace the dosing pump hoses.
- Check the respective injection valves for pH and chlorine and renew them if necessary.
Hose replacement dosing pump:
Technical data
Display| 4.3″ TFT colour touchscreen, 32bit microprocessor, enhanced
graphic acceleration
---|---
Regulation| Adaptive proportional control
Measurement of pH value| Single-rod sensor, BNC
Measuring range pH| 0 – 10.0
Measurement of Redox value| Single-rod sensor, BNC
Measuring range Redox| 0 – 999 mV
Cable lenght sensors| 2.5 m
Max. pump delivery pressure| 1.5 bar
Max. pump flow rate| 2.4 l/h
Electrical connection| 240 V~, 50/60 Hz
Power consumption| Controller max. 10 W / Dosing pumps max. 2x 8 W
Protection class of the device| IP 65
Operating temperature| 0 °C – 40 °C // 32 °F – 104 °F
Dimension of the controller| 315 x 210 x 94 mm (H x W x D)
Weight of the controller| Approx.: 1.9 kg
Declaration of Conformity
We,| BAYROL Deutschland GmbH Robert-Koch-Str. 4 82152 Planegg/Steinkirchen
Germany
---|---
hereby declare that the models of the product named in the following that we
bring into circulation meet the requirements of the indicated EC directive.
Product designation:| Measurement, control, and dosing system for swimming
pools
Product model:| AutomaticCl-pH
Series no.:| see type plate
EC directives:| EC – Low Voltage Directive (2014/35/EU) EC – Radio Equipment
Directive (2014/53/EU) EC – EMC Directive (2014/30/EU)
Harmonizing standards used:| EN61000-3-2, EN61000-3-3, EN61000-4-2,
EN61000-4-3, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8,
EN61000-4-11
Date, manufacturer signature:| 01.03.2022
Signer’s information:| Lars Birckenstaedt, Managing Director BAYROL Group
Note! UK CA Declaration of Conformity.
Disposal instructions
Disposal of electrical and electronic household appliances in the European
Union
All products marked with this symbol must not be disposed of with household
waste after use. It is the user’s responsibility to dispose of this type of
waste by taking it to a recycling centre suitable for the selective disposal
of electrical and electronic waste. The appropriate recycling and treatment of
this waste contribute significantly to the preservation of the environment and
the health of users. For more information on collection points for this type
of waste, please contact the retailer from whom you purchased the product or
your local council.
Safety instructions
Hazards from non-compliance with safety information
Non-compliance with safety information can result in hazards to persons, the
environment, and the equipment.
Non-compliance with safety information will result in a forfeit of any
potential right to damage compensation.
Professional installation
This product must be installed, commissioned and operated by a competent
swimming pool professional. All applicable installation rules and local
regulations must also be observed.
This product is intended for use in private swimming pools only.
Disconnect power supply (unexpected start-up)
The controller starts operation as soon as there is voltage on the incoming
power line. Dosing pumps may start turning at any time.
Potential consequence: damage to property or health
- The unit must be disconnected from the power supply before any service work is carried out.
Caustic, Corrosive and fire-promoting dosing liquids
The dosing liquids used are caustic, corrosive and fire-promoting.
Potential consequence: damage to property or health (also danger to
life).
- During commissioning and operation, always observe all relevant health and safety regulations as well as the safety data sheets of the products used.
- Never leave the ends of the dosing hoses hanging loosely to avoid possible contact of the water care products with each other or with other liquids or components.
Chlorine gas development on contact of pH-Minus and liquid chlorine
Toxic chlorine gas is produced when pH-Minus and liquid chlorine come into
contact.
Potential consequence: damage to property or health (also danger to
life).
- Make sure that pH-Minus and liquid chlorine never come into contact with each other.
- Make sure that pH-Minus and liquid chlorine are never dosed into standing water.
- It is essential that the power supply for the dosing pumps is switched so that the dosing pumps are only supplied with power when the circulation pump is running.
Potential overdosing of liquid maintenance products
Despite comprehensive safety functions of the device a sensor failure and
other errors may result in an overdosing of liquid maintenance products.
Potential consequence: damage to property or health
- Set up your installation so that uncontrolled dosing is not possible in the event of sensor failure and other errors, and/ or such that uncontrolled dosage is recognised and halted before damage is incurred.
Opening the housing
Danger of electric shock in case of opening the casing.
Potential consequence: damage to property or health (also danger to
life).
- Do not open the unit casing of the controller, especially if the controller is connected to power supply network.
Dangerous system settings
Changing system settings (default values) can be dangerous under certain
circumstances.
Potential consequence: Damage to property or health.
- Settings must be changed by trained technicians only.
- The operator assumes liability if settings are used improperly or modified.
Unauthorised access
Unauthorised access may result in dangerous settings.
Potential consequence: damage to property or health.
- Make sure unauthorised access to the controller and accessories such as buffer and cleaning solutions is not possible at any time.
- In particular, exclude access to the appliance and accessories by children.
Unexpected start-up
The unit starts working as soon as voltage is applied to the mains input. The
dosing pumps can start at any time.
Potential consequence: Damage to property or health.
- Do not supply the unit with voltage until all preparations for safe start-up and operation have been completed.
Use of products from other manufacturers
The use of products from other manufacturers, such as hydrochloric acid for pH
regulation, may result in serious damage in a short time!
Potential consequence: Damage to property or health.
- The system may only be operated with original BAYROL products and BAYROL spare parts only.
- BAYROL does not accept liability for issues caused by using other manufacturers’ products or spare parts.
Disregard of mandatory change of components
Not changing relevant components may cause leakages of malfunction. Caustic
and corrosive liquids can escape.
Potential consequence: damage to property or health (also danger to
life).
- Change all in the maintenance plan named components in the specified intervals.
- Check the components for proper condition and function at the intervals specified in the maintenance plan.
Dosing liquids in hoses and components
Dosing pump, hoses, injection valve and foot filter are filled with dosing
liquids during operation. Caustic and corrosive liquids can escape during
maintenance work.
Potential consequence: damage to property or health
- Before maintenance work, flush the dosing pumps and all connected components with water for at least 5 minutes as shown in the illustration.
- Avoid any contact with the dosing liquids.
- Wear suitable protective clothing. Wear protective clothing.
- Familiarise yourself with the safety instructions for the dosing liquids used.
IMPORTANT NOTICE!
Compliance with the relevant accident prevention regulations, as well as other
legal regulations and the generally recognised safety rules must be ensured by
the system operator!
BAYROL Deutschland GmbH
Robert-Koch-Straße 4 · D-82152 Planegg
Telefon : + 49 (0)89 85701-0
info@bayrol.de ·
www.bayrol.de
BAYROL France SAS
2 Chemin des Hirondelles – CS 19548
F -69572 Dardilly Cedex
Tél. +33 (0)4 72 53 23 87
www.bayrol.fr
BAYROL Deutschland GmbH
Robert-Koch-Str. 4 · D-82152 Planegg
Phone: + 49 (0)89 85701-0
info@bayrol.de ·
www.bayrol.com
BAYROL Ibérica SLU
Avda Diagonal 453 bis Planta Entresuelo
E-08036 Barcelona
Tel. +34 93 272 48 48
www.bayrol.es
References
- BAYROL Webportal
- BAYROL Webportal
- BAYROL Webportal
- BAYROL Webportal
- Make the most of your pool | Bayrol
- BAYROL Deutschland | Poolpflege | Dosiersysteme | Ratgeber
- Experto en el tratamiento del agua de piscinas | BAYROL
- L'évidence pour tirer le meilleur parti de votre piscine | Bayrol
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>