FLASH F2000364 Spotlight Profile 200W RGBW Light User Manual
- June 13, 2024
- FLASH
Table of Contents
F2000364 Spotlight Profile 200W RGBW Light
SPOTLIGHT PROFILE
200W RGBW 12o-30o
MANUAL
**User Manual
EAN [5905358808610] Art No F2000364
**
WARNING! Use clamp to rig the fixture.
WARNING! When clamping the fixture to a truss or other structure at any
other angle than with the yoke hanging vertically downwards, use two clamps of
half-coupler type. Do not use any type of clamp that does not completely
encircle the structure when fastened.
WARNING! Position or shade the bar so that the front lens will not be
exposed to sunlight or any other strong light source from any angle – even for
a few seconds. See Figure 1. The SPOTLIGHT lens can focused the
sun’s rays, creating a potential fire hazard and causing damage.
IMPORTANT! Do not point strong light output from other fixtures at the
SPOTLIGHT, as intense illumination can damaged the display.
INTRODUCTION
THANK YOU FOR PURCHASING SPOTLIGHT. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.
SAFETY INFORMATION
-
Please keep this User Manualfor future consultation. If you sellthe fixture to another user, be surethat they also receive this instruction booklet.
-
Unpack and check carefully there is no transportation damage before using the fixture.
-
Before operating, ensure thatthe voltage and frequency of power supply match the powerrequirements of the fixture.
-
It’s important to ground theyellow/green conductor to earthin order to avoid electric shock.
-
Disconnect main power beforeservicing and maintenance.
-
Use safety chain when fixes this fixture. Don’t handle the fixture bytaking its head only, but always bytaking its base.
-
Maximum ambient temperatureis: 40°C Don’t operate it where thetemperature is higher than this.
-
In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself.
Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. -
Do not connect the device to any dimmer pack.
-
Do not touch any wire during operation and there might be a hazard of electric shock.
-
To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
-
The housing must be replaced if they are visibly damaged.
-
Do not look directly at the li- ght spot while the fixture is on.
PRODUCT INFORMATION
Light Source:
RGBW 4in1 LED
Power consumption: 200W
Power supply voltage:
100-240V, 50/60Hz AC
Macro Auto programs
Zoom: Manual
Focus: Manual
Beam angle: 12º-30º
Operating modes: DMX512,
Manual, Auto, Sound-controlled, Master/Slave, Sound active,| D M X c h a n n e
l m o d e 9 C H
IP Rating: IP25
Housing made: Aluminium
Cooling: Active
AC IN/OUT: PowerCon
3-Pin XLR DMX Input/Output
Net Weight: 10 kg
Gross weight: 12,2 kg
Net Dimensions:
H(25)xW(74)xD(26,5) cm
Pack Size:
H(37)xW(83)xD(35) cm
---|---
INSTALATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it. The fixture may be installed in any orientation, but if installed horizontally with a downward beam-angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. However, in loca- tions with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling. Two quarter-turn brackets are supplied with the fixtre if it is to be flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps. Fasten a safety cable between the support structure and the attachment point on the fixture. The safety cable must be able to bear at least 10 times the weight of the fixture.
The package includes:
- – SPOTLIGHT (1 pc)
- – Power cable type powerCON (1 pc)
- – powerCON out plug (without cable) – (1 pc)
- – User Manual (1 pc)
- – DMX cable (1 pc)
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3(5)-pin socket
- Power (in/out): powerCON socket
The connection is performed using cable with XLR-female -> XLR-Male plugs.
CAUTION! At the last fixture, the DMX signal has to be terminated with a
terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a
XLR plug and plug it in the DMX output of the last fixture.
Diagram of connection of devices by DMX cable.
IMPORTANT! The maximum number of devices connected in series via power
cable is 8 pcs. The connection is performed using power cable with powerCON
connector (included). The device must be operated by qualified personnel.
CAUTION! In the case of cable damage do not attempt to repair.
Replacement or repair can be made only on the manufacturer or by a person with
appropriate permissions Using lamp, the change rate of power voltage should be
within ±10%, if the voltage is too high, it will shorten the light’s life.
Voltage Specification.
Input Voltage | Frequency | Total Power |
---|---|---|
100-240[V] AC | 50/60[Hz] | 220[W] |
Control Menu
Operation instructions: under the main menu, press the up and down key to
select different functions menus. After selecting different function menus,
press the „OK” key to enter the corrensponding drop-down menu function. In the
drop-down menu, press the „increase” or „decrease” key to modify its parameter
value. Press ok to return to the main menu.
Color screen display window comparison table
No | DISPLAY |
---|---|
1 | DMX-Addr 001 |
2 | Key-ADJ |
Green | 0-255 |
Blue | 0-255 |
White | 0-255 |
Dodge | 0-255 |
3 | Auto-ADJ |
Auto-Sound | 3 |
Speed | 0-100 |
4 | Screen Rotate |
Comparison table of background display window in English (To enter the MENU, long press ENTER)
No | DISPLAY | The initial value |
---|---|---|
1 | Fan temp | 20-70 |
2 | Lowpower temp | 35-90 |
3 | Protect temp | ON/OFF |
4 | RedCurrent | 20-255 |
5 | GreenCurrent | 20-255 |
6 | BlueCurrent | 20-255 |
7 | WhiteCurrent | 20-255 |
8 | Language | EN |
9 | Screen saver | ON/OFF |
DMX CHART
NO | FUNCTION | DESCRIPTIONS |
---|---|---|
1 | Dimming | R, G, B, W Total dimming, linear dimming, from dark to light |
2 | Total Strobo | R, G, B, W Total strobo, from dark to light |
3 | R Dimming | R, dimming, from dark to light |
4 | G Dimming | G, dimming, from dark to light |
5 | B Dimming | B, dimming, from dark to light |
6 | W Dimming | W, dimming, from dark to light |
7 | Feature | 0-50: DMX 8 Channel control: |
51-100: jump
101-150: the gradient
151-200: pulse variable
201-255: voice control
8| Speed| Speed, from slow to fast
9| CTO| Color temperature 4000K – 10000K
RDM Instructions (optional)
NO | FUNCTION | DESCRIPTIONS |
---|---|---|
1 | Feedback (address code) | Free to change |
2 | Feedback (equipment temp.) | Cannot be changed |
After power-on, turn on the console power supply. When the signal of DMX512
console is not recived, the DMX indicator does not turn on.
When the signal of DMX512 console is received, the DMX indicator lights up,
which is controlled by the console signal.
In the address code state, if there is no console after multi-computer
connection, the master-slave online function can be realized. One of the
devices can be operated. The other devices in the address state run
synchronously with the host. When the master-slave online, DMX512 signal must
be cut off.
FLASH-BUTRYM Sp.j.
Skarbimierzyce 18 · 72-002 Dołuje · POLAND
WWW.FLASH-BUTRYM.PL
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>