eurolite 40001705 LED IP PFE 40 Instruction Manual

June 13, 2024
eurolite

LED IP
PFE-40
CW/WW 15-30°
CW/WW 25-50°
User Manual

40001705 LED IP PFE 40

LED IP PFE-40 CW/WW
Weather-proof spotlight (IP65), 40 W COB LED, variable color temperature, CRI

90, RDM

No. 40001705, 15-30°
No. 40001706, 25-50°
www.eurolite.de

This user manual is valid for the article numbers: 40001705, 40001706
You can find the latest update of this user manual in the Internet under: www.eurolite.de
DANGER! Electric shock caused by short-circuit
Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires. Never open the housing.
Please read these instructions carefully before using the product. They contain important information for the correct use of the product.
Every person involved with the installation, operation and maintenance of this device has to

  • be qualified
  • follow the instructions of this manual
  • consider this manual to be part of the total product
  • keep this manual for the entire service life of the product
  • pass this manual on to every further owner or user of the product
  • download the latest version of the user manual from the Internet

INTRODUCTION

Thank you for having chosen one of our products. If you follow the instructions given in this manual, we are sure that you will enjoy this device for a long period of time.
Product features
Weather-proof spotlight (IP65), 40 W LED, variable color temperature, CRI

90, RDM

  • 1 powerful LED 40 W COB (chip-on-board) 2in1 BCL CW/WW (homogenous color mix)
  • Variable color temperature 2700 K – 6000 K
  • 4 shutter blades
  • Gobo holder for own gobos with an outside diameter of 37.5 mm, image diameter max. 28 mm and thickness of 1.5mm, included in delivery
  • Can be operated in 1; 2; 3; 6 CH mode
  • Controlling by stand-alone; Master/slave function; DMX; RDM
  • Strobe effect
  • With a beam angle of 15° – 30° or 25° – 50°
  • Very high color rendering index (CRI)
  • With mounting bracket
  • 4 digit 7-segment LED display
  • Zoom manual; Focus manual
  • Dimmer electronic; Dimmer speed (step response) adjustable; pulse-width modulation variable
  • Preprogrammed in Light Captain
  • Mains input and output (via Y-mains adapter cable) for power linking up to 8 units

SAFETY INSTRUCTIONS

WARNING!
Please read the safety warnings carefully and only use the product as described in this manual to avoid accidental injury or damage.
Intended use

  • This product is designed to light indoor and outdoor areas and is IP65 rated. It can be mounted and operated in indoor and outdoor areas. This device is designed for professional use in the field of event technology, e.g. on stage. It is not suitable for household lighting.
  • Only use the device according to the instructions given. Damages due to failure to follow these operating instructions will void the warranty! We do not assume any liability for any resulting damage.
  • We do not assume any liability for material and personal damage caused by improper use or non-compliance with the safety instructions. In such cases, the warranty will be null and void.
  • Unauthorized rebuilds or modifications of the device are not permitted for reasons of safety and render the warranty invalid.

Danger due to electricity

  • To reduce the risk of electric shock, do not open any part of the device. There are no serviceable parts inside the device.
  • Only connect the device to a properly installed mains outlet. The outlet must be protected by residual current breaker (RCD). The voltage and frequency must be exactly the same as stated on the device. If the mains cable is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never deactivate the protective ground of a mains cable. Failure to do so could possibly injure the user.
  • For outdoor use make sure to connect a rubber cable H05RN-F or H05RR-F. For installations in the ground an underground power cable NYY must be used. All valid instructions concerning the installation of cables outdoors or in the ground must be adhered.
  • The mains outlet must be easily accessible so that you can unplug the device quickly if need be.
  • Never touch the mains plug with wet or damp hands. There is the risk of potentially fatal electric shock.
  • The mains cable must not be bent or squeezed. Keep it away from hot surfaces or sharp edges.
  • Never pull the mains cable to disconnect the mains plug from the mains outlet, always seize the plug.
  • Unplug the device during lightning storms, when unused for long periods of time or before cleaning.
  • Do not expose the device to any high temperatures, direct sunlight, strong vibrations or heavy mechanical stress.
  • Do not immerse the product in water, this will destroy it. Furthermore, this could cause a lethal electric shock!
  • Only have repairs to the device or its mains cable carried out by qualified service personnel. Repairs are required when the device or the mains cable is visibly damaged, when the device has been dropped or malfunctions occur.

Danger to children and people with restricted abilities

  • This product is not a toy. Keep it out of the reach of children and pets. Do not leave packaging material lying around carelessly. Never leave this device running unattended.
  • This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.

Warning – risk of burns and fire

  • The admissible ambient temperature range (Ta) is -5 to +45°C. Do not operate the device outside of this temperature range.
  • The housing temperature (Tc) can be up to 75°C during use. Avoid contact by persons and materials.
  • Do not illuminate surfaces within 20 cm of the device. This value is indicated on the device by the symbol.
  • Do not use the device near highly flammable materials. Always place the device at a location where sufficient air circulation is ensured. Leave 50 cm of free space around the device. Never cover the air vents of the housing.

Warning – risk of injuries

  • Do not look directly at the light source. Persons with light-sensitive epilepsy may suffer from epileptic seizures or fall unconscious.
  •  Make sure that the product is set up or installed safely and expertly and prevented from falling down. Comply with the standards and rules that apply in your country, in particular EN 60598-2-17.
  • If you lack the qualification, do not attempt the installation yourself, but instead use a professional installer. Improper installation can result in bodily injury and or damage to property.
  • The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions.
  • For overhead use, always secure the device with a secondary safety attachment such as a safety bond or safety net.
  • Make sure that the area below the installation place is blocked when rigging, derigging or servicing the device.
  • For commercial use the country-specific accident prevention regulations of the government safety organization for electrical facilities must be complied with at all times.

Caution – material damage

  • This device must not be connected to the mains voltage by means of a dimmer.
  • Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.
  • Never switch the device on and off at short intervals. This will considerably reduce the service life of the device.
  • If the device has been exposed to drastic temperature fluctuation, do not switch it on immediately. The resulting condensation may destroy the device. Allow the device to reach room temperature before connecting it. Wait until the condensation has evaporated.
  • Please use the original packaging to protect the device against vibration, dust and moisture during transportation or storage.
  • If a serial number label is affixed to the device, do not remove the label as this would void the warranty.

DESCRIPTION OF THE DEVICE

  1. Mounting bracket
  2. Hole for fastening the coupler
  3. Fixation screw
  4. Shutter blades
  5. Safety eyelet for securing the fixture
  6. Manual focus – fixation screw
  7. Manual zoom – fixation screw
  8. Clamp mounting for color filter frame
  9. Color filter frame with hole for fastening a safety bond
  10. Gobo holder/Gobo holder slot
  11. LED display with operating buttons
  12. DMX input
  13. Power input

Inserting/Exchanging gobos
If you wish to project a gobo pattern, please follow the instructions below:

  1. Loosen the two screws on the metal plate in front of the gobo holder slot and slide the plate slightly forward (See graphic).
  2. Carefully insert the gobo holder with the desired gobo into the gobo holder slot.
  3. Carefully slide back the metal plate and tighten the screws.

INSTALLATION

WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing down. Make sure that the device is installed securely and cannot fall down. The installation must be carried out by a specialist who is familiar with the hazards and the relevant regulations.
The device may be placed on the floor or fastened to a truss or similar rigging structure. The device must never be fixed swinging freely in the room.

  1. The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
  2. Block access below the work area and work from a stable platform when installing the device.
  3. Use rigging hardware that is compatible with the structure and capable of bearing the weight of the device. Please refer to the “Accessories” section for a list of suitable rigging hardware.
  4. Secure the device with a safety bond or other secondary attachment. This secondary safety attachment must be sufficiently dimensioned in accordance with the latest industrial safety regulations and constructed in a way that no part of the installation can fall down if the main attachment fails. An appropriate eyelet is mounted on the device for fixation of the safety bond. Fasten the safety bond in such a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm.
  5. To align the device, release the fixation screws at the mounting bracket, adjust the desired inclination angle and tighten the fixation screws.
  6. After installation, the device requires inspections periodically to prevent the possibility of corrosion, deformation and looseness.

eurolite 40001705 LED IP PFE 40 - DESCRIPTION2

CONNECTIONS

Power Supply

The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts. The power connector is designed according to protection class IP65.
Note: When not in use, make absolutely sure to close the connection with the rubber sealing cap on the device to prevent moisture and dirt from penetrating.

  1. Connect the device via the enclosed mains cable to a grounded mains socket. Thus the unit is switched on.
  2. To switch off the unit, disconnect the power plug.
  3. Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains outlet which is switchable.

Note: To supply power to several devices in series, you require a Y-mains adapter cable. (See chapter Accessories ).
Matching connection cables with special plugs (Y-mains adapter cables) are optionally available.
Mains connection for multiple devices via an optionally available Y-mains adapter cable (see graphic):

  1. Connect the enclosed power cord (F-socket) to the M-plug of the Y-mains adapter cable.
  2. Connect the F-socket of the adapter cable to the device. Now connect the second F-socket of the first adapter cable to the M-plug of the second adapter cable.
  3. In this manner, up to 8 devices can be linked at 230/240 input voltage and up to 4 devices at 110/115 input voltage.
  4. Connect the device via the enclosed mains cable to a grounded mains socket. Thus the unit, or rather the units, is/are switched on.
  5. To switch off the unit, disconnect the power plug.
  6. Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains outlet which is switchable.

eurolite 40001705 LED IP PFE 40 - Power Supply1

Note: When not in use, be sure to close the unused plug or socket with the supplied rubber sealing cap to prevent moisture and dirt from entering.

DMX512 control
Note: To connect multiple devices in series, please use the supplied Y-XLR adapter cable. (See chapter Accessories).
DMX connection for multiple devices via supplied Y-XLR adapter cable (see graphic):
A DMX512 data link is required in order to control the device via DMX. The device provides a 3-pin XLR connector for DMX connection.

  1. Connect the output of your controller to the M-plug of the adapter cable.
  2. Connect the F-socket of the Y-XLR adapter cable to the first device. Another Y-XLR adapter cable (M-plug) can be attached to the second F-socket.
  3. In this way, you can connect the devices in the chain until all devices are connected.
  4. At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal (–) and Signal (+) in the DMX output of the last unit.
  5. If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended to insert a DMX level amplifier to ensure proper data transmission.

eurolite 40001705 LED IP PFE 40 - control

Note: When not in use, make absolutely sure to close the connection with the rubber sealing cap on the device to prevent moisture and dirt from penetrating.
XLR connection:
DMX-input XLR mounting-plug:

  1.  Ground
  2. Signal (—)
  3. Signal (+)

OPERATION

After connecting the device to the mains it is ready for operation. The operating modes can be selected by means of the display and the control buttons. All settings remain stored even if the device is disconnected from the mains.
The device can be operated in stand-alone mode via the control board or in DMX-controlled mode via any commercial DMX controller.
Press the MENU button to access and browse through the main menu. Press the ENTER button in order to select the desired menu item. You can change the selection by pressing UP or DOWN. Confirm every selection by pressing the ENTER button. The functions provided are described in the following sections.
Menu structure
Default settings shaded

Main Menu Sub menu Function
A001 001 – 512 Setting the DMX starting address
CHnL Setting DMX Mode
1CH 1-Channel DMX Mode
2CH 2-Channel DMX Mode
3CH 3-Channel DMX Mode
6CH 6-Channel DMX Mode
Fail DMX Lost Mode
Hold Most recent DMX value is held
Full All LEDs 100% on
Blnd LEDs switched off
dinn Master Dimmer (Master Mode)
000 – 255 Total brightness 0 – 100%
Strb Strobe (Master Mode)
S.00 – S.20 Increasing speed
Dimmer (Master Mode)
uL– u.000 – u.255 WW increasing brightness 0 – 100%
cL– c.000 – c.255 CW increasing brightness 0 – 100%
nodE Dimmer speed (step response)
nod.0 Response characteristics of LEDs: No delay
nod.1 Response characteristics of halogen lamps, fast
nod.2 Response characteristics of halogen lamps, less fast
nod.3 Response characteristics of halogen lamps, middle
nod.4 Response characteristics of halogen lamps, slow
tEnP t— Inner temperature
UErn xxx Software Version
rSEt Restore factory settings
PnnF Pulse-width modulation
0.6F / 1.2F / 2.0F / 4.0F / 12F / 24F With this function, the PWM frequency

of the LEDs can be set: 600Hz, 1200Hz, 2000Hz, 4000Hz, 12000Hz, 24000Hz

Stand-alone mode
In stand-alone mode, the device can be used without controller. Disconnect the device from the controller and call up the menu you want to use. Please refer to the instructions under Menu structure.
Manual focus adjustment

  1. Loosen the focus fixation screw on the side of the device.
  2. Adjust the focus by sliding the fixation screw forwards or backwards.
  3. Tighten the focus fixation screw on the side of the device.

Manual zoom adjustment

  1. Loosen the zoom fixation screw on the side of the device.
  2. Adjust the zoom by sliding the fixation screw forwards or backwards.
  3. Tighten the zoom fixation screw on the side of the device.

eurolite 40001705 LED IP PFE 40 - Fig1

Master/slave operation
Note: To connect multiple devices in series, please use the supplied Y-XLR adapter cable. (See chapter Accessories).
Master-slave connection for multiple devices via supplied Y-XLR adapter cable (see graphic):
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled with the master unit without the need for a DMX controller. The devices must be set to the corresponding operating modes.

  1. Configure all slave units before connecting the master unit. For this, set each Slave device to the same DMX address (for example 001) and confirm with ENTER.
  2. Connect the F-socket of the Y-XLR adapter cable to the first device. Another Y-XLR adapter cable (M-plug) can be attached to the second F-socket.
  3. In this way, you can connect the devices in the chain until all devices are connected.
  4. Make sure the master unit is the first in the chain. Do not connect a DMX controller to the DMX input of the master unit.
  5. Select the desired mode at the master unit (See Menu Structure). The interconnected devices will now operate synchronously.

eurolite 40001705 LED IP PFE 40 - Fig2

Note: When not in use, be sure to close the unused plug or socket with the supplied rubber sealing cap to prevent moisture and dirt from entering.
RDM
With this function, you can call up various submenus via RDM.
This device is RDM ready. RDM stands for “Remote Device Management” and makes remote control of devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when the device is installed in a remote area.
RDM is integrated in the DMX-transmission line without influencing the connections. New DMX-cables are not necessary. RDM ready and conventional DMX devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
DMX operation
Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 6 control channels. However, it can also be switched to a mode with 1, 2, or 3 channels if different functions are required. To be able to operate the device with a DMX controller, the DMX starting address must be set. The starting address depends upon which DMX controller is being used. Please refer to the controller’s documentation.

  1. Press the MODE button so many times until A001 is indicated on the display. Confirm with the ENTER button.
    Via the UP/DOWN buttons you can set the desired starting address. Confirm with the ENTER button.

  2. In order to set the desired DMX channel mode, press the MENU button until CHnL is indicated on the display and press ENTER. The display indicates 1CH (1 DMX channel), 2CH (2 DMX channels), 3CH (3 DMX channels), or 6CH (6 DMX channels). Use the buttons UP/DOWN to select the desired DMX channel mode. Confirm with the ENTER button.

  3. A dot on the display will flash when DMX signals are being received.

Note: Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX chain. If several devices are defined to the same address, they will work synchronously.

Functions in DMX mode

1-channel mode

Channel: Value Function:

1
Master dimmer| 000 – 255| Total brightness 0 – 100%

2-channel mode

Channel: Value Function:

1
Master dimmer| 000 – 255| Total brightness 0 – 100%
2
Strobe| 000 – 255| Strobe effect with increasing speed 0 – 100%

3-channel mode

Channel: Value Function:

1
Master dimmer
| 000 – 255| Total brightness 0 – 100%
2
WW
| 000 – 255| Intensity from 0 – 100%
3
CW
| 000 – 255| Intensity from 0 – 100%

6-channel mode

Channel: Value Function:

1
Master dimmer
| 000 – 255| Total brightness 0 – 100%
2
WW
| 000 – 255| Intensity from 0 – 100%
3
CW
| 000 – 255| Intensity from 0 – 100%
4
Color temperature CW – WW
| 000 – 010| No function
011 – 255| Decreasing color temperature 6000 K – 2700 K
5
Strobe
| 000 – 255| Strobe effect with increasing speed 0 – 100%
6
Dimmer speed
| 000| No function
001 – 051| Response characteristics of LEDs: No delay
052 – 102| Response characteristics of halogen lamps, fast
103 – 153| Response characteristics of halogen lamps, less fast
154 – 204| Response characteristics of halogen lamps, middle
205 – 255| Response characteristics of halogen lamps, slow

CLEANING AND MAINTENANCE

The outside of the device should be cleaned periodically to remove contaminants such as dust etc. The lens, in particular, should be clean to ensure that light will be emitted at maximum brightness.

  1. Disconnect the device from power and allow it to cool before cleaning.
  2. Clean the surface with a soft lint-free and moistened cloth. Never use alcohol or solvents as these may damage the surface. Make sure that no liquids can enter the device.
  3. The device must be dry before reapplying power.

There are no serviceable parts inside. Do not open the housing. Do not try to repair the device by yourself as this may result in damage. Maintenance and service operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts. Should you have further questions, please contact your dealer.

PROTECTING THE ENVIRONMENT

Disposal of old equipment
**** When to be definitively put out of operation, take the product to your dealer or a local recycling plant for a disposal which is not harmful to the environment. Devices marked with this symbol must not be disposed of as household waste. Contact your retailer or local authorities for more information. Remove any inserted batteries and dispose of them separately from the product.

TECHNICAL SPECIFICATIONS

Power supply: 100-240 V AC, 50/60 Hz
Power consumption: 30 W
IP classification: IP65
Protection class: Protection class I
Power connection: Mains input via IP T-Con (M) mounting version Power supply

cord with safety plug (provided)
Lamp type:| LED lamp
LED:| 1 x 40 W COB (chip-on-board) 2in1 BCL CW/WW (homogenous color mix)
Color temperature:| 2700K – 6000K adjustable
Equipment:| Zoom manual; Focus manual
Gobos:| Outside diameter 37,5mm
Image diameter 28mm
Thickness 1.5mm
DMX channels:| 1; 2; 3; 6
DMX input:| 1 x 3-pin XLR (M) mounting version IP
Control:| Stand-alone; Master/slave function; DMX; RDM; Light Captain
Beam angle (1/2 peak):| 15 – 30° – Article 40001705| 25 – 50° – Article 40001706
Color rendering index (CRI):| 92 Ra
Housing color:| Black
Attachment system:| Mounting bracket
Display type:| 4 digit 7-segment LED display
Dimensions:| Length: 34.5 cm
Width: 15.5 cm
Height: 28.5 cm
Weight:| 4.50 kg

eurolite 40001705 LED IP PFE 40 - Fig3

Accessories

EUROLITE TPC-10 Coupler, silver No. 59006856
EUROLITE Safety Bond A 3x600mm up to 5kg, silver No. 58010310
EUROLITE Gobo Holder for LED IP PFE-40 No. 40001704
EUROLITE Adapter Cable IP T-Con(m)/2xT-Con(f) No. 30235009
EUROLITE Adapter Cable DMX IP XLR 3pol(m)/2xIP XLR 3pol(f) No. 30227869
PSSO DMX cable IP65 3pin 7.5m black No. 3022783E
EUROLITE IP T-Con Connection Cable 3×1.5 3m No. 30247754

All information is subject to change without prior notice. © 17.05.2023

Eurolight is a brand of Steiniger Showtechnic GmbH
Andreas-Bauer-Str. 5 · 97297 Waldbüttelbrunn Germany

D00147165.docx Version 1.0 Publ. 17/05/2023
00147165.DOCX, Version 1.0
28/28

Documents / Resources

| eurolite 40001705 LED IP PFE 40 [pdf] Instruction Manual
40001705 LED IP PFE 40, 40001705, LED IP PFE 40, IP PFE 40, PFE 40
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals