GE PK-00102798-6 CYNC Smart Light Switch Installation Guide

June 13, 2024
GE

GE logo Smart Switch Installation Guide
On/Off Button No Neutral Wire/3-Wire Switches
Models: CSWONBLBWF1NN, CSWONBLPWF1NN, CSWONBLTWF1NN

PK-00102798-6 CYNC Smart Light Switch

WARNING: RISK OF ELECTRIC SHOCK
This product installation requires handling 120 volt wiring. Follow each step carefull.
If you have any concerns handling wiring, hire a qualified electrician. Ensure all work meets local and federal regulations.

Simple DIY Set Up

| Install your Smart Switch
---|---
GE PK 00102798 6 CYNC Smart Light Switch - Symbol 2| Download the CYNC App, powered by Savant
| Add your Smart Switch to the CYNC App

GE PK 00102798 6 CYNC Smart Light Switch - Symbol
4Compatibility Requirements

  • Rating 120V AC 60Hz
  • Neutral wire is not required (Wire is usually white or grey and is not required)
  • Ground wire is required (Wire is usually green, green with a yellow stripe, or copper) ****
  • Wi-Fi 80211 b/g/n @ 2.4 GHZ is required
  • Works with halogen, incandescent, and LED bulbs, including Cyne Smart Bulbs
  • Not for use with ceiling fans
  • LED up to 1.25 amps (150 Watts)
  • Incandescent/halogen up to 5 amps (600 Watts)
  • Minimum Load 15 Watts
  • If you are using less than 15 Watts, non-dimmable LED bulbs, or Cync Smart Bulbs on the circuit, you will need to use the included Bulb Adaptor
  • Use the optional Fixture Adaptor (available separately) where the Bulb Adaptor will not fit Contact Customer Support at 1-844-302-2943 for details.

GE is a trademark of General Electric Company. Used under trademark license.
Amazon, Alexa, and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
Google, Android and Google Home are trademarks of Google LLC.

! IMPORTANT NOTE ON 3-WAY WIRING:
Some lights have one wall switch, while others are controlled by two or more wall switches (such as stair lights, which have a switch at both the top and bottom of the stairs). If your lights have more than one switch (called a 3-way), we’ve created other instructions for this type of installation.

Visit cyncsupport.gelighting.com for 3-way installation instructions and how- fo videos.
Note: Complete set up in the CYNC App to enable 3-way/ multi-way functionality.

Let’s Do It

Included:GE PK 00102798 6 CYNC Smart Light Switch -
Included

You’ll need:GE PK 00102798 6 CYNC Smart Light Switch -
need Approximately 30 minutes of your day to install and set up the switch

You Got This!
And we’re here fo help.
For in-depth instructional videos and a guided tour through the installation, go fo:
cyncsupport.gelighting.com
or call 1-844-302-2943
NOTE: Please make sure your system is up-to-date, and you update the frmware when prompted for the best experience.

https://l.ead.me/bczWdg
Scan here for videos & guided installation steps.

BEFORE YOU DO ANYTHING:
Step 1

Turn Off The Power!

  1. Turn off the power for the swiftch location at the circuit breaker box.
  2. Test existing switch by toggling switch on/ofi, ensuring lights do not turn on.
  3. Now, follow these setup steps for a single gang switch.

STOP! Before Proceeding to Step 2, Determine the Bulb Type
What type of bulbs do you plan to use? Some installations require the included Bulb Adaptor to maintain Wi-Fi connectivity and to ensure your switch and bulbs work together.
If your switch circuit includes a load of at least 15 Watts:

TYPE OF LIGHT BULB IS AN ADAPTOR REQUIRED?
Incandescent/Halogen No
Dimmable LEDs No
Non-Dimmable LEDs Yes
Cync smart lights Yes

If your switch circuit does NOT include a load of at least 15 Watts:

TYPE OF LIGHT BULB IS AN ADAPTOR REQUIRED?
Incandescent/Halogen Yes
Dimmable LEDs Yes
Non-Dimmable LEDs Yes
Cync smart lights Yes

Installing the Bulb Adaptor

  1. Twist the Bulb Adaptor onto the base of the medium-base (E26) light bulb.
  2. Screw the bulb and Adaptor into the fixture.

NOTE: Only one Bulb Adaptor is needed per switch, even if there are multiple light bulbs on the circuit. If installing in a recessed can application, you may need to adjust the recessed can depth to ensure the bulb is flush.
If the Bulb Adaptor does not fit your bulb or fixture, you have other options:

  • Replace your lights with incandescent, halogen, or dimmable LED light bulbs that meet the 15 Watt minimum load requirement. See a list of compatible bulbs at gelighting.com/cync
  • Install our Fixture Adaptor to the actual fixture in the ceiling.
    For install instructions and where to get a Cync Fixture Adaptor (available separately), confact Customer Support at 1-844-302-2943

Step 2

Remove Your Old Switch

  1. Remove the existing wall plate and switch from the wall.

  2. Use voltage tester on the black wires to confirm power to the switch is off (recommended).

  3. Before disconnecting the wires from the wall, label each with the provided wire labels.
    Ground wire is required. If you don’t have this wire, the Cync Smart Switch is not compatible.

  4. Disconnect wires and remove existing switch.

GE PK 00102798 6 CYNC Smart Light Switch - existing
switch

Step 3

Connect The Wires

Note: Both black wires on the switch are interchangeable and can be connected fo either the load or line wire from the wall

  1. Connect the first line/load (black) wire on the switch to the line or load (black label) wire from the wall

  2. Connect the second line/load (black) wire on the switch fo the line or load (black label) wire from the wall

  3. Connect the ground & (green) wire on the switch with the ground (green label) wire from the wall

  4. Cap the 3-way/multi-way traveler wire (if applicable). For 3-way switch setup, visit gelighting.com/cync
    Attention: Incorrectly connecting the ground wire from the wall to the ground wire on the switch will damage the product.

  5. Cap the neutral wire from the wall (if applicable). Neutral wire is not required to operate this switch.

GE PK 00102798 6 CYNC Smart Light Switch - neutral
wire

Step 4

Fit Wires Into Wall Box

Neatly push the wires back info the box, rotating the switch 50 it’s orienfed according fo the image, and the arrow on the switch is pointing up. GE PK
00102798 6 CYNC Smart Light Switch - Fit Wires

Step 5

Secure The Switch

  1. Using a Phillips screwdriver and screws provided, secure the switch fo the wall until level and flush.
  2. Screw on the wall plate bracket and then snap on the wall plate cover onto the bracket.

****If using your existing wall plate, you may need to replace the existing wall plate screws with the short screws provided.

Step 6

Turn The Power Back On

To enable the full experience, you’ll need fo set up all your products in the Cync App. If you’ve set up Cync bulbs in the Google Home app, Visit cyncsupport.gelighting.com for unpairing instructions.

TROUBLESHOOTING
LED indicator light or light ring will flash blue until the switch is added fo the Cync App.
LED indicator light or light ring will not illuminate if wired incorrectly or if the switch circuit does not meet the specified load requirements.

If lights don’t turn on:

  1. Check that power to the switch is on at the breaker.
  2. Turn power off at the breaker, return to the switch to confirm the wires are securely and properly wired according to the installation guide.

NOTE: Remote wall plate and use pin to press reset button.
If lights flicker, experience intermittent power loss, or won’t completely turn off:

  1. Be sure to select the correct bulb type in the Cync App.
  2. Your installation may require a Bulb/Fixture Adaptor or a different bulb type.

Go to cyncsupport.gelighting.com for more froubleshooting

Congratulations!

You’ve completed the Smart Switch installation.

Next ……

GE PK 00102798 6 CYNC Smart Light Switch - Symbol 2| Download the CYNC App
---|---
| Add your Smart Switch to the CYNC App
| Set up your Alexa or Hey Google voice assistant (optional)

Enable Your Voice Assistant

Connect to your Amazon Alexa or Google Assistant device in the CYNC App. Then try this…
Alexa, turn off the living room.
Alexa, turn on the bedroom.
Alexa, set kitchen to 50%
Hey Google, turn on the lights.
Hey Google, good morning.
Hey Google, I’m leaving.

Additional Information and Warnings

FCC Compliance Statement Compliance Notice:
This equipment has been tested and found fo comply with the limits for a Class B digital device, pursuant fo part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inferference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any inferference received, including interference that may cause undesired operation.

Changes or modifications that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

RF Exposure Information:
This equipment complies with FCC radiation exposure limits sef forth for an uncontrolled environment. In order fo avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 8 inches during normal operation.

RF Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 8 inches from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

Caution (dimmer)
To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle or motor-operated appliance or transformer-supplied appliance.
These devices are infended to be wired with field wiring having a minimum insulation rating of 75°C.

Caution High Voltage

  • Disconnect power supply before servicing
  • Operation temperature: 0 to 40°C
  • For Control of Electronic Ballast, CFLs, LED, and LED Lamps
  • Type 1 Enclosure
  • IP20
  • Pollution Degree 2
  • Impulse Voltage: 2500V
  • Type 1 action

Indoor use only

Like your new Smart Switch?
Share your experience!
Leave a review where you purchased the product.

For set up help, visit cyncsupport.gelighting.com or call 1-844-302-2943.
PK-00102798-6

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>