GE PK-00104825-2 Undercabinet LED Warm White 8W LED Direct Wire 12in Integrated Light Fixture Installation Guide
- June 13, 2024
- GE
Table of Contents
GE PK-00104825-2 Undercabinet LED Warm White 8W LED Direct Wire 12in Integrated Light Fixture
PRODUCT COVERED
Model| Input voltage
(Voe, Hz)| Current
(mA)| Wattage (W)
---|---|---|---
UNCBR12DW@| 120, 60| 75| 8
UNCBR18DW@| 120, 60| 120| 13
UNCBR24DW@| 120, 60| 160| 17
Where@= can be followed by additional letters, numbers or symbols which indicate CRI, CCT, finish color, packaging or internal identification.
DIMMING
The luminaire is dimmable with most regular dimmers.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
- Risk of fire or electric shock. Installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- This device is not intended for use with emergency exits.
- These products are intended to be used in dry or damp locations.
Prepare Electrical Wiring
Electrical Requirements
The LED fixture must be supplied with 120VAC 60Hz.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code(NEC) Article 600 and local codes.
PACKAGE CONTENTS
TOOLS REQUIRED
-
Drill
-
Screwdriver
-
Wire stripper
Note: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation.
Risk of Damage: Must use UL approved conduit fittings for all enclosure box connections ta prevent wire cuts by sharp edges and excessive strain on wiring.
DIRECT WIRE INSTALLATION
-
Turn off power source to the power supply you are installing the fixture in.
-
Remove front cover by unscrewing the screws. Do not pull with excessive force.
-
Drive the screws into the mounting surface until approximately 1/8″ (~3mm) of space remains under the head of the screw and surface. The screw spacing needs to be 9.6″, 15.6″ and 21.6″ for 12″, 18″ and 24″ fixture respectively. It may be required to pre-drill a pilot hole for the screws.
-
Choose a suitable knock-out location from the eight options. Remove the knock-out with a screwdriver. Do not leave the removed metal circle inside the fixture.
-
Mount strain relief to the fixture by inserting the threaded end through the knock-out and tighten nut. Strain relief should be on the outside of the connection cover with the nut on the inside. Push supply cable through the strain relief ensuring roughly 3″ of coble is through the fitting. Tighten screws around the supply cable.
-
Connect each supply cable to internal wire with respective color by using provided wire nut. Black to black, white to white, and green (or bare copper wire) to green. Make sure that all wires are securely gripped, and no bare wires are exposed.
-
Align the keyholes in the fixture with the two screws and slide into place. Tighten screws to secure fixture.
-
Put front cover back to fixture and tighten screws. Turn on the electricity at the circuit breaker or fuse box and verify that the fixture functions properly.
Customer Support
GE is a trademark of General Electric Company. Used under trademark
license.
INFORMATION PROVIDED IS SUBJECT TO CHANGE WITHOUT NOTICE. ALL VALUES ARE
DESIGN OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS.
©2021 GE Lighting, a Savant Campany.
GE Lighting, a Savant Company
1-800-435-4448
www.gelighting.com