GE xrzkpca1y4maiprytutm LED Linkable Motion Daylight 250W Replacement Integrated LED Outdoor Security Fixture Installation Guide
- June 13, 2024
- GE
Table of Contents
GE xrzkpca1y4maiprytutm LED Linkable Motion Daylight 250W Replacement
Integrated LED Outdoor Security Fixture
Outdoor fixture
- Contoins FCC ID : PUU-LINKABLE-0B01
- Contoins IC : 10798A-LINKABLE001
BEFORE YOU BEGIN
Read these instructions completely and carefully. Before installing the light
fixture, ensure that all parts are present.
This product must be installed ln accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Prepare Electrical Wiring
Electrical Requirements
L.!J The LED spotlight must be supplied with 120VAC 60Hz.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code(NEC} Article 600 and local codes.
PACKAGE CONTENTS
Part | Quantity | Description |
---|
I
J
| I
I
| Outdoor fixture
Motion sensor head
K| I| User operation manuol
L| I| Driver box
M| 2| Light heod
Note: User operation manual on motion sensor head must face down.
HARDWARE PACKAGE
Part | Quantity | Description |
---|---|---|
A | 2 | Mounting bracket screw |
B | 2 | Mounting bracket screw |
C | 2 | Mounting bracket screw |
D | 2 | Rubber screw hole plug |
E | I | Mounting bracket |
F | I | Gasket |
G | 3 | Wire connector |
H | 2 | Nut screw |
TOOLS REQUIRED
SPECIFICATIONS
INSTALLATION
Warning: Before wiring the fixture to the house power supply, ensure the
electricity is TURNED OFF at the main circuit breaker or fuse box. DO NOT
ATTEMPT TO INSTALL FIXTURE WITH THE POWER ON. All wiring Connections must be
mode with the POWER OFF to avoid personal injury and/or damage to the fixture.
Verify power is OFF at the junction box using AC voltage tester before
installation. If using ladder for installation, ensure ladder base is secure
and stable before attempting light fixture installation.
Select Mounting location
- Determine the mounting location -Wall or Eave mount.
- Position the lamp heads (Ml in the general direction of the desired light coverage.
- NOTE: The outdoor fixture (I) is WET rated for outdoor use and should be mounted to a recessed electrical junction box with a 120-Volt AC power source ideally connected through a wall switch.
- NOTE: The outdoor fixture (I) should be mounted approximately at a maximum 15 ft. (4.5ml height above the ground. If the light fixture (I) is mounted lower than recommended, aiming the motion sensor head (J) up will change the coverage area.
- NOTE: For the recommended detection coverage area, position the motion sensor head UI at about 15° to 20° beam angle below horizontal position.
- NOTE: The light source(sl IMI should not be directly positioned toward motion sensor head (J).
INSTALLATION (cont.I
Turn off power source to the junction box that you ore installing the fixture
in.
Remove the mounting bracket (El from the back of outdoor fixture (I).
- Install the mounting bracket (E) to junction box. The bracket has slots to accommodate 2.75 or 3.5 inch mounting centers.
- NOTE: Six mounting bracket screws (A, B or C) of three sizes are included. The installation will only require one set of two screws.
- Remove the existing outdoor fixture and disconnect house AC Power supply wires (black, white and ground).
- Install the mounting bracket (E) with two screws pointing away from the junction box. Use the mounting bracket screws (A B or Cl that best fit the junction box.
- Fit the position of mounting bracket (E), and attach, positioning the two screws in vertical orientation.
- Tighten the mounting bracket screws IA, B or C).
Slide gasket lf) over mounting screws and pull supply wires through center hole.
INSTALLATION
Make the electrical connections.
- WARNING: Before wiring the fixture to the house power supply, ensure the electricity is TURNED OFF at the main circuit breaker or fuse box. DO NOT ATTEMPT TO INSTALL FIXTURE WITH THE POWER ON. All wiring connections must be mode with the POWER OFF to avoid personal injury and/ or damage to the fixture. Verify power is OFF at the junction box using AC voltage tester before installation.
- Connect black wire from outlet box to black wire from fixture. Connect white wire from outlet box to white wire from fixture. And connect ground wire from outlet box to ground wire from fixture. Secure wires together with wire connector (GI.
- Please moke sure fixture is orientated correctly, refer to UP arrows shown below.
Mount the fixture (I) to the mounting bracket (El.
- Put the fixture (II on the mounting bracket (E) with two screws through the hole on fixture.
- Take the nut screw (H) from hardware package, put nut screw (H) into the hole at the front of fixture, tighten nut screw (H) with tool.
- Complete second nut screw (H) installation.
- Put the rubber screw hole plug (DI into the hole at the front of fixture.
- For wet locations, o bead of caulking compound such as acrylic latex or silicone must be placed around the perimeter of backplate also contacting the flange (as shown) to seal against mounting surface keeping water away from the outlet box and back openings.
Adjust the light head (Ml and motion sensor head IJI to the desired position. Once the fixture is secured,
INSTALLATION (summary)
Adjust the motion detection zone Set the sensor head far optimal motion detection
- NOTE: For the recommended detection coverage ore□, position the motion sensor head Ul at about 15° to 20° beam angle below horizontal position .
- NOTE: The light heads IM) should not be directly positioned toward motion sensor head Ul.
- The sensor will be more sensitive to motion across its detection path than motion directly towards it
FUNCTION AND OPERATION MANUAL
Operation Switch
Dusk to Down | Night, Dusk, Doy (3 level adjustable) |
---|---|
Timer | 10s, 30s, 3min, 10min and Always |
Sensitivity | PIR sensor detection distance: Low, Medium or Hiah |
Brightness | 0%, 15%, 30%, 50%, 100% in standard operation |
Grouo | A, B, C, and D, X seporotelv from anu rirouo |
Linking Groups | Within 2 minutes of “power on” press the Web button on one |
fixture
Operation Steps
- [Built in Dusk to Dawn Sensor]
- Day: Light will operate all the time.
- Dusk: Light will operate from dusk to down. At dawn the lamp will stop operating.
- Night: Light will operate from night to dawn.
- [Setting Activation Timer]
- The activation timer determines the amount of time the light will stay on full brightness after last motion is detected.
- Timer can be set to 10s, 30s, 3min, lOmin and Always. Setting the timer to always will always maintain light output on desired fixture.
- [Setting Sensitivity]
- Set the sensitivity af the PIR sensor to LOW, MEDIUM or HIGH
- Low: The sensor detection distance is approximately 25 feet.
- Medium: The sensor detection distance is approximately 40 feet.
- H i gh: The sensor detection distance is approximately 60 feet.
- [ Setting Brightness]
- Set the brightness of the light in standard operation.
- Brightness can be set to 0%, 15%, 30%, 50%, 100%.
- Note 1 : When motion is detected the light will illuminate from established brightness to 100% brightness.
- Note 2 : When the light is powered on, it will maintain 100% brightness for 15 seconds.
- After 15 seconds, all lights will return to brightness level set.
- [ Setting Group]
- The fixtures can be divided and linked into four groups : A, B, C, and D. If one fixture in the group is triggered via motion, the other fixtures linked to the same group simultaneously turns on to 100% brightness.
- To operate your fixture separately from any group set the setting to “X”.
- [Linking Groups]
To link fixtures
- Set the desired fixtures to the same Group (A, B, C or D) on the control panel.
- Power on the desired fixtures.
Note 1 : Fixtures will flash 3 times to indicate the fixtures are now
linked.
Note 2 : All the group linkable lights should set up at the same time.
FCC requirements
This device complies with port 15 of the FCC Rules. Operation is subject to
the following two conditions
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to port 15 of the FCC Rules. These limits ore designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures
- Re-orient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IC requirements
- This device complies with CAN ICES-0058.
- This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 20 cm (8 inches) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
- This equipment complies with the FCC radiation exposure limits set possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 8 inches during normal operation.
Contains FCC ID : PUU-LINKABLE-0B01
Contains IC : 10798A-LINKABLE001
GE Lighting • 1-800-435-4448 •
www.gelighting.com
T ?E GE BRAND AND LOGO ARE TRADEMARKS OF THE GENERAL ELECTRIC COMPANY. ©2019
GE LIGHTING.
INFORMATION PROVIDED S SUBJECT TO CHANGE WITHOUT NOTICE. ALL VALUES ARE DESIGN
OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS.
Read User Manual Online (PDF format)