EX MARKINGS
ATEX:
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db
EU Type Examination Certificate:
EPS 22 ATEX 1 341 X
CE-designation: 2004
IECEx:
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
IECEx Certificate: IECEx EPS 22.0076X
Japan Ex:
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
TIIS Certificates: TC22900X, TC22901X
Temperature range:
- 20°C … +55°C (EN/IEC 60079-0)
- 10°C … +55°C (EN/IEC 62368-1)
Manufactured by: i.safe MOBILE GmbH
i_Park Tauberfranken 10 97922 Lauda-Koenigshofen Germany
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and has read and understood Operating Manual, Safety Instructions and certificate. When used in explosion hazardous areas, the following Safety Instructions must also be complied with:
-
Inside explosion hazardous areas the covers of all interfaces (USB, ISM Interface) must be closed.
-
Within explosion hazardous areas, the following accessories may be used when connected to
- the ISM interface:
- the Headset IS-HS2A.1
- the Headset IS-HDHS1x.1
- the PTT Button IS-PTTB1A.1 together with the Headset IS-HDHS1x.1
- the PTT Button IS-PTTB1A.1 without Headset IS-HDHS1x.1 other accessories approved by i.safe MOBILE GmbH.
The 16-pin ISM connector of the accessory must be securely fastened to the ISM interface.
-
If the PTT Button IS-PTTB1A.1 is connected to the ISM interface of the device together with the Headset IS-HDHS1x.1, the connection between the IS-PTTB1A.1 and the Headset ISHDHS1x.1 can be disconnected and reconnected in explosion hazardous areas. When using the IS-PTTB1A.1 without the Headset IS-HDHS1x.1, the unused cable end of the IS-PTTB1A.1 may remain open in explosion hazardous areas.
-
When using accessories with Velcro fasteners (e.g. Headset IS-HDHS1B.1), the Velcro fastener may only be adjusted outside explosion hazardous areas.
-
To ensure the IP-protection, it has to be ensured that all gaskets are present and functional.
-
There must be no large gap between the two halves of housing and between the battery compartment cover and housing.
-
The device may only be charged outside explosion hazardous areas using the i.safe PROTECTOR 2.0 USB-C Cable or other charging equipment approved by i.safe MOBILE GmbH.
-
The microSD cards type IS-SD164.1 and IS-SD1128.1 or microSD cards which comply with the intrinsic safety entity parameters mentioned in the certificate, may be used in the corresponding slot in the hazardous area.
-
Nano-SIM cards which comply with the intrinsic safety entity parameters mentioned in the certificate, may be used in the corresponding slot in the hazardous area.
-
The device may only be charged at ambient temperatures between 0°C … +45°C.
-
The device may not be exposed to any aggressive acids or alkalis.
-
The device may only be used in zones 1, 2, 21, or 22.
FAULTS AND DAMAGES
If there is any reason to suspect that the safety of the device has been
compromised, it must be withdrawn from use and removed from any ex-hazardous
areas immediately.
Measures must be taken to prevent any accidental restarting of the device. The
safety of the device may be compromised, if, for example:
- Malfunctions occur.
- The housing of the device shows damage.
- The device has been exposed to excessive loads.
- The device has been stored improperly
- Markings or labels on the device are illegible.
We recommend that a device displaying errors or in which an error is suspected be sent back to i.safe MOBILE GmbH to be checked.
INFORMATION CONCERNING SAR CERTIFICATION (SPECIFIC ABSORBATION RATE)
The SAR limit of Europe is 2,0 W/kg for the head and body, 4,0 W/kg for the limbs. The device has been tested against this SAR limit. The highest SAR value reported under this standard during product certification for use at the ear is 1,27 W/kg and when correctly worn on the body is 1,23 W/kg, limbs is 2,3 W/kg.
This device was tested for typical body worn operations with the back of the handset kept 5 mm from the body. The device complies with RF specifications when used at 5 mm from the body. Belt clips, holsters and similar accessories used should not contain metallic components in the assembly. The use of accessories that do not satisfy these requirements may not comply with RF exposure requirements, and should be avoided.
FCC/IC STATEMENT
The FCC/IC declaration can be found at www.isafe- mobile.com/en/support/downloads
CUSTOMERS SUPPORT
IS540.1 | MODEL M540A01
Document No. 1058MM09REV00
Version: 2023-09-11
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel. +49 9343 60148-0
info@isafe-mobile.com
www.isafe-mobile.com
(c) 2023 i.safe MOBILE GmbH
References
- AT&T Official Site | Our Best Wireless & Internet Service
- Zertifizierte Smartphones, Tablets und Mobiltelefone für IECEx und ATEX Zonen
- Datasheets, Manuals, Certificates and Product Folders
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>