Pegasus PP-6750V Series Dual Frequency Time Attendance Recorder Instruction Manual

June 13, 2024
PEGASUS

Pegasus PP-6750V Series Dual Frequency Time Attendance Recorder

Product Information

  • Product Name : PC On-Line Time Attendance Recorder & Access Controller
  • Product Type : Access Control/Time & Attendance / Lift Access Control System/ Security
  • Model : PP-6750V Series
  • Operational Manual Version : 21.2
  • Manual Number : 2110 W-04-6750V/E 1

Product Usage Instructions

To get started with the 6750V system, please follow these instructions:

  1. Check the package contents to ensure you have received all the necessary items.

  2. Connect the system unit using the provided connectors (9 Pin
    connector, 8 Pin connector, 4 Pin connector, and 3 Pin connector).

  3. Refer to the wiring connectors and PIN assignment section for guidance on how to properly connect the system.

  4. If needed, refer to the example of wiring and controller and relay box wiring examples for further assistance.

  5. Read the macro instruction section for information on how to program the system.

  6. Change the master PIN if required. Instructions for changing the master PIN can be found in the system programming section.

  7. Refer to the function code instructions for different functions and settings:

  8. Delete all personal map (Function Code F0)

  9. Access by key in user ID through master PIN (Function Code F1)

  10. Set weekday, hour, minute (Function Code F2)

  11. Calendar year, month and date setting (Function Code F3)

  12. Parameters & Modes (Function Code F4)

  13. Follow the instructions in the different groups for system configurations, input commands, output commands, operation modes, pin or master pin setting, inquiry mode, time zone mode/add card mode, delete card mode, system configurations, and factory configuration.

  14. Use the inquiry mode (Function Code F5) to retrieve information about single cards, cards with learning mode, and card status by block mode.

  15. Use the add personal map (Function Code F6) to add cards with or without PIN, in learning mode or from a specific group.

  16. Use the delete personal map (Function Code F7) to delete single cards or cards with learning mode or block mode.

  17. Use the time zone/holiday/bell programming (Function Code F8) to set personalized time zones, floor settings, personalized timezone inquiry, delete time zones, free access mode, auto duty mode, auto mode, holiday mode, and bell alarm mode.

  18. Modify events counter for event retrieving (Function Code F9) if necessary.

  19. Use the inquiry and display the stored events (Function Code F*) to retrieve and display stored events.

  20. Refer to the simple and easy troubleshooting section for any issues you may encounter.

  21. Consult the appendix for additional information.

Packing List
Before getting started, please check that the 6750V package contains the following items:

DESCRIPTION Q’TY
The system unit 1 unit
9 Pin connector (Blue) 1 pc
8 Pin connector (White) 1 pc
4 Pin connector (White) 1 pc
3 Pin connector (White) 1 pc
Screw 1 pc
Free wheeling diode 1 pc
Sealing rubber for waterproof 1 pc

Packing List

Before getting start, please check the 6750V package contains the following items:

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(1\)

System introduction

6750V is an intelligent time recording terminal designed to meet the variant applications in time attendance and access control, lift control & ARM/DISARM security requirements.Each terminal can be operated independently or through PC/Internet adapter PC-T100 to fulfill the multiple terminal system. The recording terminal includes nearly all the necessary functions for time recording and access control.Users can use master PIN to select the desired functions from the abundant functional list (For malfunction, please contact with your local distributors) The system could be started by modifying the factory defaulted templated as by code F4 + 0850 and then save them by 0650 to back up for farther configuration your system by 0950, if you confused your configuration.

General Features

Time recording features:

  1. 1. High capacity with 8 digits card number / 6 digits staff number and 8 character English name.( Either checking or without checking personal map )
  2. 16 characters x2 rows of LCD disply with 8 digits which have year, month,day,week,time, IP,operation mode,real time mode,unlock time, door monitoring.
  3. 79 duty codes, duty name defined by PC.
  4. Selectable batch or real time on-line mode.
  5. Key in 8 digits ID for time attendance recording.
  6. Totally 192 alarm schedules (8 schedules per hour) dry contacts output for periodic bell announce.

There are 6 versions available:

  1. K Version: 1,000 card capacity, 500 events.
  2. L Version: 2,000 card capacity, 1,000 events.
  3. M Version: 30,000 card capacity, 10,000 events.
  4. N Version: 11,000 card capacity, 32,000 events.
  5. P Version : 11,000 card capacity, 8,000 events.
  6. X Version: 32,000 card capacity, 32,000 events.

Versions could be getting thru the equipped RS-485 interface.

Access control features:
(Main application)

  1. System parameters and personal access map can be down loaded by PC or manually programmed through
  2. The personal access map is consisted of card ID, staff number and staff name, PIN and Time Zone Status, expiry date and

Anti-passback.Operation modes :

  1. card only
  2. card + PIN
  3. Door PIN only and duress feature
  4. Card no +PIN and duress feature
  5. Free access
  6. Automatic operation mode by time zones

NOTE : The staff name is used under F4=9601, 3400 cards capacity only.

  1. Individual personal access map can be added/deleted and checked by on-lined PC or through manually in single / block range card number or by direct reading card in learning
  2. Selectable immediate or batched serial output for event printing

With complete door release, status monitoring and intruded alarm periord & error trials

Specification

|
---|---
Dimensions| :137mm(L) x 85mm(W) x 29mm(H)
Weight| :340g± 5%
Power supply| :DC 12V±10%, 80mA~100mA(not include power

requirement for lock & alarm)

Transmission rate| :Default 9,600 bps N,8,1(2,400bps/4,800bps)

(19,200bps/38,400bps)

Operating temperature| :-20℃ ~ 70℃
Operating humidity| :10%~90%
Keypad| :3 x 4 keypad for system programming,

pass word entry or duty code selection.

Password| :Programmable 4 digits PIN for each person
Serial interface| :RS-485/RS-232(Optional)

Serial output

| :1. For connection with serial printer.

*2. To drive DDR (digital door relay) for safety control model.

3. Lifts controller. common door codes

Card capacity /Events| :(1) K Version: 1,000 card capacity, 500 events.

(2)  L Version: 2,000 card capacity, 1,000 events.

(3)  M Version: 30,000 card capacity, 10,000 events.

(4)  N Version: 11,000 card capacity, 32,000 events.

(5)  P Version: 11,000 card capacity, 8,000 events.

(6)  X Series: 32,000 card capacity, 32,000 events. Other capacity combination requested by order

Card standard| :125KHz ASK EM / 125KHz FSK HC / 13.56MHz Mifare (ISO 14443A , ISO 14443B, ISO 15693) /

13.56MHz Felica (ISO 18092 UID) / Q type / NFC / Bluetooth

※ Support customized card.

External Reader

| :With one or optional two port for external Wiegand

(26/34/35/36/37/40 bits definable by command) & ABA input (by order)

Specification|
---|---
Dimensions| :137mm(L) x 85mm(W) x 29mm(H)
Weight| :340g± 5%
Power supply| :DC 12V±10%, 80mA~100mA(not include power

requirement for lock & alarm)

Transmission rate| :Default 9,600 bps N,8,1(2,400bps/4,800bps)

(19,200bps/38,400bps)

Operating temperature| :-20℃ ~ 70℃
Operating humidity| :10%~90%
Keypad| :3 x 4 keypad for system programming,

pass word entry or duty code selection.

Password| :Programmable 4 digits PIN for each person
Serial interface| :RS-485/RS-232(Optional)

Serial output

| :1. For connection with serial printer.

*2. To drive DDR (digital door relay) for safety control model.

3. Lifts controller. common door codes

Card capacity /Events| :(1) K Version: 1,000 card capacity, 500 events.

(2)  L Version: 2,000 card capacity, 1,000 events.

(3)  M Version: 30,000 card capacity, 10,000 events.

(4)  N Version: 11,000 card capacity, 32,000 events.

(5)  P Version: 11,000 card capacity, 8,000 events.

(6)  X Series: 32,000 card capacity, 32,000 events. Other capacity combination requested by order

Card standard| :125KHz ASK EM / 125KHz FSK HC / 13.56MHz Mifare (ISO 14443A , ISO 14443B, ISO 15693) /

13.56MHz Felica (ISO 18092 UID) / Q type / NFC / Bluetooth

※ Support customized card.

External Reader

| :With one or optional two port for external Wiegand

(26/34/35/36/37/40 bits definable by command) & ABA input (by order)

LCD INSTRUCTIONS

Normal Display: After plug-in power, LCD displays as below:

  • Y Y/ M M / D D: The calendar year, month and date (Year/ Month/ Day)
  • h h:mm :System clock, Hour & Minute (hh=00~23;mm=00~59)
  • X X X: weekday Monday to Sunday
  • NNNNN :The transaction records stored in the buffer.

When display shows “FULL”, which means the butter is full. Please download the records by PC or press Master PIN and then press”9”,key-in “000000” to erase the events.

Parameter display: key-in ―9‖, LCD displays as below:

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(3\)

  • Aaa : Polling address by F4=88aa (00~99)
  • WAT :Real time on-line waiting time by F4=890t (0~9), ―0‖ for baten mode by F4=99nn
  • DOR :Door released time by F4=21tt(00~99), S= second, M=minute
  • BPS
    • Buad Rate 96=9600
    • 48=4800 24=2400  19=19200Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG- \(4\)
  • REP :Door Monitoring Status time for check repeat reads in unit of second
  • N=t Check repeating card with t minutes N=0 No repeating card check
  • MOT: Door monitoring time by code F4=230t, S= second
  • DPT : LCD message display time by F4=250t, useful for F*
  • T-A  : Time zone control – Free access mode
  • Y – Enable function
  • N -Disable function

Note : The system could be operated in proper order only when the address code is correctly programmed through 88nn. If the reader address is not correctly programmed, the display of address will show some other ASCII characters as ―xxx― above the ADR.which can’t save the event; therefore you should program again.

Third display

  • R.rrrrr: The read counter of buffer

  • W.wwwww:
    The write counter of buffer

  • Version :CPU version

Note : Accoring to actual version.

Panel Description

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(6\) Bottom View

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(7\) Wiring Connectors and PIN assignment

J2-9P Blue (For power input and access functions)

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(8\)

Note:

  • Please connect the blue wire to GND if the Door Monitoring function isunnecessary.
  • Please connect the purple wire to GND if the Security Sensor function is unnecessary.

J1-8P White (For on-line interface & alarm output)

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(9\)

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(10\)

Need to set F4 = 9816, when connect with the external reader that Model No. is included ―PW26‖

Note:

  1. The distance between Main reader and external reader sould be over 30cm to prevent mutual interference.
  2. Please put some more no-metal plate between the reader & metal plate to enhance the reading distance.

Example of how to wiring

Wiring connection with external relay and power supply

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(11\)

Wiring connection with external relay and power supply for heavy load locks

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(12\)

8F relay box connector

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(13\)

24F relay box connector

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(14\)

  • R-27-YK10T1/125/250V is line filter to avoid signal interference.
  • If elevator controller doesn’t work; please turn off ―Bypass switch‖ of non-controlled button.
  • To connect 2 or 3 of 24 floor controllers to achevie 64 floors access of set up.
  • Please refere appendix for floor controller of relate operation manner.

Controller and Relay Box Wiring Example

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(15\)

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(16\)

System Initialize (default password 246890)
Please set the F4 = 0016 / F4 = 0018 / F4 = 0019 / F4 = 0 072 to prevent the time zone data occupy memory and further caused the card number can not be enrolled.

The system initialization means the system parameters are defaulted by F4=0850 (off-line mode) or F4=0750(on-line mode). Then the user could modify some parameters based on it. After each modification to individual requirement, the user may backup them by code F4=0650. Once the parameters are destroyed, the code F4=0950 could be applied to restore it. All the function code under F4 is disabled, except the timer for 21tt, 22…..

  1. Door monitoring: :Disable the door monitor function ( F4=1100 )
  2. Presonal map compare :Not compare ( F4=1500 )
  3. Door release time :close one second(F4=2101)
  4. Door open mode :card only mode(F4=3200)
  5. Anti-pass back mode : Disable ( F4=3900 )
  6. Check repeat card : Disable ( F4=8300 )
  7. Printer output function :Disable ( F4=8600 )
  8. When event buffer full :Not recycle ( F4=8700 )
  9. Computer connect mode :real time mode ( F4=8903 )-F4=0750 batch mode ( F4=8900 )-F4=0850
  10. Card display format :Comparing card number 5th, 6th, 7th digits ( F4=9704 )

Operating instruction

The manager could program the controller by pressing ―0‖ and master PIN (default password as ―246890‖.The password could be modified by F4=4609) to enter into the PROGRAM mode.Summary of fuctions code please refer to ndex on the system introduction.

  1. F0  : Delete all personal map
  2. F1  : Key in user ID for access by master PIN
  3. F2  : Set weekday, hour, minute
  4. F3  : Program Calendar year, month and date
  5. F4  : Parameter modes & Modes
  6. F5  : Inquiry Personal access map
  7. F6  : Add personal map
  8. F7  : Delete personal map
  9. F8  : Time zone/holiday/bell programming & Inquiry
  10. F9  : Modify events counter for event retrieving
  11. F10 : Display or print out recorded

Note :The programming procedures could be escaped by pressing ”#” by key

Macro Instruction(Optional)

For “Access Control”macro instruction

F4=0851

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0851] For PN/Q/M8/M1 format

Parameter mode:
F4=9996 F4=9803 F4=2106 F4=1501 F4=8700| :Baud rate:9600

:Wiegand 26 bits card number.

:Door release time: 6 sec.

:Enable comparing card number.

:For FIFO mode.

| F4=2500 F4=1101 F4=3402 F4=9705| :The shortest time of display.

:Enable the door monitoring.

:Enable door PIN mode.

:Compare card number by 6th , 7th , 8th digits.

F4=0852

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0852] For M0 format

Parameter mode:
F4=9996 F4=9808 F4=2106 F4=1501 F4=8700| :Baud rate:9600

:Wiegand 34 bits card number.

:Door release time: 6 sec.

:Enable comparing card number.

:For FIFO mode.

| F4=2500 F4=1101 F4=3402 F4=9704| :The shortest time of display.

:Enable the door monitoring.

:Enable door PIN mode.

:Compare card number by 5th , 6th , 7th digits.

For “Lift Control” macro instruction

F4=0853

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0853] For PN/Q/M8/M1format

Parameter mode:
F4=9996| :Baud rate:9600| F4=2500| :The shortest time of display.
F4=9803| :Wiegand 26 bits card number.| F4=8610| :Enable lift control 8 floor.
F4=2108| :Door release time: 8 sec.| F4=1100| :Disable the door monitoring.
F4=1501| :Enable comparing card number.| F4=9705| :Compare card number by
F4=8700| :For FIFO mode.| | 6th ,7th , 8th digits.

F4=0854

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0854] For M0 format

Parameter mode:
F4=9996 F4=9808 F4=2108 F4=1501 F4=8700| :Baud rate:9600

:Wiegand 34its card number.

:Door release time: 8sec.

:Enable comparing card number.

:For FIFO mode.

| F4=2500 F4=8610 F4=1100 F4=9704| :The shortest time of display.

:Enable lift control 8 floor.

:Disable the door monitoring.

:Compare card number by 5th 6th, 7th digits.

F4=0855

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0855] For PN/Q/M8/M1format

Parameter mode:
F4=9996 F4=9803 F4=2108 F4=1501 F4=8700| :Baud rate:9600

:Wiegand 26 bits card number.

:Door release time: 8 sec.

:Enable comparing card number.

:For FIFO mode.

| F4=2500 F4=8623 F4=1100 F4=9705| :The shortest time of display.

:Enable lift control 24 floor.

:Disable the door monitoring.

:Compare card number by 6th, 7th , 8th digits.

F4=0856

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0856] For M0 format

Parameter mode:
F4=9996| :Baud rate:9600| F4=2500| :The shortest time of display.
F4=9808| :Wiegand 34 bits card number.| F4=8623| :Enable lift control 24 floor.
F4=2108| :Door release time: 8 sec.| F4=1100| :Disable the door monitoring.
F4=1501| :Enable comparing card number.| F4=9704| :Compare card number by
F4=8700| :For FIFO mode.| | 5th, 6th, 7th digits.

F4=0857

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0857] For PN/Q/M8/M1format

Parameter mode:
F4=9996| :Baud rate:9600| F4=2500| :The shortest time of display.
F4=9803| :Wiegand 26 bits card number.| F4=8633| :Enable lift control 48 floor.
F4=2108| :Door release time: 8 sec.| F4=1100| :Disable the door monitoring.
F4=1501| :Enable comparing card number.| F4=9705| :Compare card number by
F4=8700| :For FIFO mode.| | 6th, 7th, 8th digits.

F4=0858

Step Description
Press[0]→master PIN [246890]→Press[4] →Press[0858] For M0 format

Parameter mode:
F4=9996| :Baud rate:9600| F4=2500| :The shortest time of display.
F4=9808| :Wiegand 34 bits card number.| F4=8633| :Enable lift control 48 floor.
F4=2108| :Door release time: 8 sec.| F4=1100| :Disable the door monitoring.
F4=1501| :Enable comparing card number.| F4=9704| :Compare card number by
F4=8700| :For FIFO mode.| | 5th, 6th, 7th digits.

Brief system programming

Change the master PIN
Ex.Change the master PIN to 654321,than F4+4609+654321. The new master PIN would be changed to 654321

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[4]| *FUNC–>——–| Parameter mode (F4)
Press[4609] +new master

PIN[KKKKKK]

| MST.PIN- KKKKKK >| KKKKKK would be the Password

Function code instruction

F0: Delete all personal map

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[0]| *CLRALL>——–| Delete mode(F0)
Press [0000]| END—|
Repeat the last step or press [#] to escape from the programming.

F1: Direct keying master PIN

Ex. : Administrator puts in 8 codes ID of user with the personal password for a user when someone forgets bring his card

The personal password is set up by F4=3300(read a card with password model) + F6(setting personal password). Above setting can be done on the controller or computer.

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[1]| *ID    No.>——–| Access mode(F1)
Press card number [12345678]| *PIN—>| Put in the legal card numbers
Press personal password [9999]| | Put in the personal password

F2: Weekday, hour, minute setting

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into programming mode
Press[2] *TIME–>——– Time mode (F2)
Press[201536] Tuesday, 15:36 pm

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
36 F3: Calendar year, month and date setting

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[3]| *YEAR–>——–| Date mode (F3)
Press[091025]| | 2009/10/25

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(19\)After key 0 + (default master PIN) then you could press 4 plus following function codes divided in groups for easy memorize.

**F4: Most system parameters programming**

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[4]| *FUNC–>——–| Parameter mode (F4)
Press 4 digit function code| *FUNC–>XXXX|
Please refer to the function code

F5: Inquiry mode

Single card inquiry

Step LCD
Press[0] + master PIN [246890] *PROGRAM*–>
Press[5] *CARDà——–
Press card NO.[1 2 3 4 5 6 7 8] 12345678=10=9999

*ZONE--0 1 0 0 . 0 0 0 1

Repeat the last stepstep or press [#] to escape

from the programming.

| C1C2C3C4C5C6C7C8 =nn=k k k k

*ZONE-- Z1 Z2 Z3 Z4 . Z5 Z6 Z7 Z8

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(19\)

ZONE: Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8: 1~8 individual authorized time zone status.

  1. 1 : Authorized time zone
  2. 0 : Unauthorized time zone

Inquiry with learning mode (F4=5333)

Step LCD
Press[0] + master PIN [246890] *PROGRAM*–>
Press[4] *FUNC-->--
Press[5333] *CARD>-LEARN->
Present card *CARD>-LEARN->

*ZONE--0 1 0 0 . 0 0 0 1

Repeat the last stepstep or press [#] to escape from the programming.

Inquiry card status by block mode (F4=5500)

Ex. Inquiry card no. from 00020376 to 00020576

Step LCD
Press[0] + master PIN [246890] *PROGRAM*–>
Press[4] *FUNC-->--
Press[5500] *CARD>-BLOCK->
Press[00020376 1 2 0576] 0 0 0 2 0 3 7 6 =12=9999

*ZONE--0 1 0 0 . 0 0 0 1

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
37

F6: Add personal map

Add card no. with group number (Under F4=3200)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[6]| *ADD CRà——–| Add mode(F6)
Press card NO.[12345678nn]| *ADD CR>| Add card no.12345678,

And group no. nn (nn=00-99)

Repeat the last step or press [#] to escape from the programming.

Add card No. and PIN (Under F4=3300)

Ex.:Set up card No.=12345678 and PIN=9999, group No. 02

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[6]| *ADD CRà——–| Add mode(F6)
Press [12345678 02 9999]| *ADD CRà——–| Card number:12345678 Group: 2

Password: 9999

Repeat the last step or press [#] to escape from the programming.

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(18\)

Add card with learning mode: ( F4 = 6333)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into programming mode
Press[4] *FUNC à Add mode(F4)
Press[6333] *ADD CR>-LEARN-> Learning mode
Present card *ADD CR>-LEARN->

C1C2C3C4C5C6C7C8

|
Repeat the last step or press [#] to escape from the programming.

Learning mode from group nn (nn=00~79)

Step LCD Description
Press[8] DUTY.2d Enter into

programming mode

Press group nn (nn=00~79)| nn will be shown on the

right-up corner of the LCD

| Setting group no.
Press[0] + master PIN [246890]| *PROGRAM*–>| Enter into

programming mode

Press[4]| FUNC à| Add mode(F4)
Press[6333]|
ADD CR>-LEARN->| Learning mode
Present card| *ADD CR>-LEARN->

C1C2C3C4C5C6C7C8

|
Repeat the last step or press [#] to escape from the programming.

Add card by block mode: (F4 = 66nn)

Ex.Add card no. from 00020376 to 00020576, group no.01

Step|
---|---
Press[0] + master PIN [246890]|
Press[4]|
Press[66nn]|
Press [00020376 01 0576]|
Repeat the last step or press [#] to escape from the programming.

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(19\)

F7: Delete personal map

Delete single card

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[7]| *DELETE>——–| Delete mode(F7)
Press card No.[12345678]| *DELETE>——–| Delete card No.12345678
Repeat the last step or press [#] to escape from the programming.

Delete card with leaning mode (F4=7333)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[4]| *FUNC à| Parameter mode(F4)
Press[7333]| DELETE >-LEARN->| learning mode
Present card|
DELETE >-LEARN-> CCCCCCCC| Reading cards

to delete cards

Repeat the last step or press [#] to escape from the programming.

Delete time zone from group nn(nn=01~99)(F4=72nn)

Step LCD Description
Press [0] + master PIN [246890] PROGM–> Enter into

programming mode

Press [4]| *FUNC-->--| Parameter mode(F4)
Press [72nn]| *DELETE>-GROUP->| Group [nn]
Press [81828384]| *DELETE>———| Delete time zone 1,2,3,4, 5,6,7,8
Press [85868788]| *DELETE>———
Press [#]to escape from the programming.

Delete card with block mode: (F4 = 77nn)

Ex. Delete card no. from 00020376 to 00020576

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press[4]| *FUNC à| Parameter mode(F4)
Press [77nn]| *DELETE>-BLOCK->| Delete with block mode

(nn=group 01~99)

Press [00020376 nn 0576]| | from 00020376 to

00020576

Repeat the last step or press [#] to escape from the programming.

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(20\)

F8: Time zone/holiday/bell programming

  1. Personalized mode (F4=1601, time zone 01~08)
  2. Free access mode (F4=3801, time zone 11~18)
  3. Holiday mode (F4=1801)
  4. Bell alarm mode (F4=2801)
  5. Access time zone setting

Ex. define a time zone from 20:01 till 06:59 next day for Monday, Tuesday & Friday. Please define by TZ1= 2001-2359 and TZ2= 0000-0659 for crossing midnight

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——-| Time zone mode(F8)
Press [601 2001 2359]| *G.DAY->| The first time zone is

20:01pm to 23:59pm

Press [1 1111111 1]| *ZONE–>——–| Available for Monday

to Sunday

Press [602 0000 0659]| *G.DAY->| The second time zone is

morning of next day 00:00am to 06:59am

Press [0 0100110 1]| *ZONE–>——–| Available for Monday to

Sunday

Repeat the last step or press [#] to escape from the

programming.

| Setting 8 time zones

the most

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(21\)

G-DAY: defined as the following:

d1       d2 d3 d4 d5 d6 d7 d8 d9
Mnemonic g      w6 w5 w4 w3 w2 w1 w0 D
meaning     gen.    Sat Fri Thu Wed Tue Mon Sun Duty code

general week enable/disable

  • =1: general authorized, d2 ~ d8 are ignored
  • =0 : not general authorized, d2 ~ d8 should be entered one by one

d8—individual weekday enable/disable

  • = 1: legal
  • = 0: denied d9—Auto mode by time zone
  • = 1: with key
  • = 0: keypad less

Time Zone Mode/Add Card Mode

62nn Setting time zone for group (nn=01~95) (Under F=1601)

Note : Please delete all group data for first time setting group. (F4=0072)

Step LCD Description
Press [0] + master PIN [246890] PROGM–> Enter into

programming mode

Press [4]| *FUNC-->--| Parameter mode(F4)
Press [62nn]| *ADD CR>-GROUP->| Group [nn]
Press [81838183]| *ADD CR>———| Legal time zone 1,3
Time Zone: Time Zones 01~08 should be corresponding 81~88.

Ex. Group no. 3 is legal for time zone 01,03,05 , you should program F4=6203 818385 81.


Ex. Group no. 3 is legal for time zone 01,03, you should program F4=6203 8183 8183.


Ex. Group no. 3 is legal for time zone 01 , you should program F4=6203 81 818181.

Group with floor setting
(put in floor number 01~96) (F4=8613/8623/8633)

Step LCD Description
Press [0] + master PIN [246890] PROGM–> Enter into

programming mode

Press [4]| *FUNC-->--| Parameter mode(F4)
Press [62nn]| *ADD CR>-GROUP->| Group [nn]
Press [01020363]| *ADD CR>———| Legal 1th,2th,3th and

63th floors

Press [#] to finish.Please repeat the step4 for adding the fifth floor.You should fill out 8 digits for floor and fill with 00.. for blank floor like 05060000 which is legal for 5th and 6th

floors.

Personalized time zone inquiry (time zone=01~08)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——–| Time zone mode(F8)
Press [5 0 2 0 0 0 0 0 0 0 0]| ZONE–>——–

02=0900=1000=GA1

|

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(23\)

Delete time zone

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——–| Time zone mode(F8)
Press[702 0 0 0 0 0 0 0 0]| | Delete time zone 2

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(24\)

Free access mode (Time zone=11~18) (F4=3801)

Ex. Door released period decided by Nth time zone 0900-1800 on Saturday & Sunday

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into programming mode
Press [8] *ZONE–>——– Time zone mode(F8)
Press [611 0900 1800] *G.DAY–>——– Door released under

normal open mode on Monday to Sunday

Press [0 100000001 1]| *ZONE–>——–
Repeat the last step or press [#] to escape from the programming.| Setting 8 time zones

the most

Zone: defined as the following:

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(25\)

Auto duty mode (Time zone=11~18)(F4=3802)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——–| Time zone mode(F8)
Press [611 0900 1200]| *G.DAY–>——–| Time zone 09:00-12:00
Press [1 1111111 1]| *ZONE–>——–| Shift code is 1

for Monday to Sunday

Repeat the last step or press [#] to escape from the

programming.

| Setting 8 time zones

the most

Zone: defined as the following:

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(26\)

G-DAY: defined as the following:

d1       d2 d3 d4 d5 d6 d7 d8 d9
Mnemonic g      w6 w5 w4 w3 w2 w1 w0 D
meaning     gen.    Sat Fri Thu Wed Tue Mon Sun Duty code

general week enable/disable

  • =1: general authorized, d2 ~ d8 are ignored
  • =0 : not general authorized, d2 ~ d8 should be entered one by one

individual weekday enable/disable

  • = 1: legal
  • = 0: denied

Auto duty mode by time zone

  • = 1: enable(1~7), expect 4
  • = 0: disable

Duty

code

| LCD

display

| Meaning| Duty

code

| LCD

Display

| Meaning
---|---|---|---|---|---
1-| WORK| On duty| 5–| OUT| Out
2-| OFF| Off duty| 6-| BACK| Return job
3-| O.ON| Over time, on duty| 7–| BRK| Break
4-| SYSTEM| Reserved for system

service only

| 8-| DUTY.

2d

| 2 digits job code define

by user

Auto mode (Time zone no.=11~18)(under F4=3803)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into programming mode
Press [8] *ZONE–>——– Time zone mode(F8)
Press [611 1900 2359] *G.DAY–>——– Time zone 09:00~23:59
Press [1 1111111 1] ◆    ZONE–>——– Password is required after presenting a

card for

Monday to Sunday

Repeat the last step or press [#] to escape from the

programming.

| Setting 8 time zones the

most

Zone: Defined as the following

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(29\)

G-DAY: Defined as the following:

d1        d2

Mnemonic  g          w6

| d3    d4

w5  w4

| d5

w3

| d6

w2

| d7

w1

| d8        d9

w0       D

---|---|---|---|---|---
Meaning      gen.         Sat| Fri Thu| Wed| Tue| Mon| Sun    Duty code

general weekdays enable/disable

  • =1: general authorized, d2 ~ d8 are ignored
  • =0 : not general authorized, d2 ~ d8 should be entered one by one

individual weekday enable/disable

  • = 1: legal
  • = 0: denied

Auto mode by time zone

  • = 1: with key
  • = 0: keypad less

Programming Holidays ( F4=1801 )

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into programming mode
Press [8] *ZONE–>——– Time zone mode(F8)
Press [101 1001 1010] *ZONE–>——– 1001: the first holiday of

October, date of 10/10

Press [102 1002 1025]| *ZONE–>——–| 1002: the second holiday

of October, date of 10/25

Press [103 1003 1031]| *ZONE–>——–| 1003: the third holiday of

October, date of 10/31

Repeat the last step or press [#] to escape from the

programming.

| Setting 8 holidays the most

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(31\)

Holiday inquiry

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——–| Time zone mode(F8)
Press [302 1002 1234]| XX= 1 0 2 5 = XXXX = HOL| The second holiday

of October, date of 10/25

Repeat the last step or press [#] to escape from the programming.

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(32\)

Bell alarm setting
(F4=2801, after setting this function, the system disables the door monitoring function automatically.)Each hour can setup 6 alarms.

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——–| Time zone mode(F8)
Press [201 0701 0750]| *ZONE–>——–| Please refer to the following

statement

Repeat the last step or press [#] to escape from the programming.

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(33\)

Bell alarm inquiry mode (F4=2801)

Step LCD Description
Press[0] + master PIN [246890] *PROGRAM*–> Enter into

programming mode

Press [8]| *ZONE–>——–| Time zone mode(F8)
Press [40107010000]| 401=0750=0750=BEL| Please refer to the following

statement

Repeat the last step or press [#] to escape from the programming.

Meaning : 7:50 is the1st alarm time at 7 o’clock

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(34\)

Note:Under F4=2801,the bell alarm period is decided by 220t; meanwhile 2801 & 1101 code should mutually trade-off.(If 2801 is set,the 1101should be denied as 1100)

F9: Modify events counter for event retrieving
(Deleting events. Press”000000”)

Ex.Modify the Read/write counters to 00150

Step LCD Description
Press[0]+masterPIN[246890] *PROGRAM*–> Enter into

programming mode

Press[9]| *CNT     St>——-| Read/write counter

mode(F9)

Press [100 150]| DON-000150| Read/write counter is 6 digits

Modify read or write counter only:

  • Modify write counter only: F9=> 2 00150
  • Modify r ead counter only: F9=> 1 00150
  • When ―2 means write counter
  • When 1 means read counter

Inquiry and display the stored events

Ex.: Modify the read/write counter to 00150

Step LCD
Press[0] + master PIN [246890] *PROGRAM*–>
Press[*] *DSPLAY=——–
Press [50000150 ] *DSPLAY= dd HH :MM

CCCCCCCC      S     [ NNNNNN ]

  • dd : Date
  • HH : MM Hour & Minute
  • cccccccc : 8 digits ID number
  • S :Access status
  • E : Error message
  • D : Correct stored data
  • NNNNN : Event counter
  1. 50 n n n n -n n n n is the top counter
    • To display all the record lower than the counter nnnn.
  2. y y m m d d -yy = m m = Month. d d = date.
    • To display the record for specific date from existing counter downward.
  3. w 0 0 0 -w = Weekday. 0 0 0 = meaningless
    • To display the record for specific weekday from existing counter downward.

After pressing 0 + (default master PIN),you could press 4 and the following function codes divided in groups for easy memory.

SYSTEM INITIALIZATION ( optional)

0000| Delete all personal access map (deny all legal persons access status) -take around seconds depending on the

card capacity.

---|---
0016| Delete all time Zone data
0018| Delete all holiday data
0019| Delete all bell alarm data
0072| Delete all group data
0650| Save all the modified function codes as template(could be recalled by 0950)
0750| Initialize the system in real time on-line state. (The system will be initialized as: 2101, 2203, 2306, 2501,

1500, 1600, 1100, 3200, 8600, 8700, 1700, 8902,

1900…… )

The user can use this code to initialize the system then adjust the other code to meet the requirement.

0800| Initialize the system all parameters(include Group9)
0850| Initialize the system in off-line state ( same as 0750

except 8900)

0950| To recall the saved template.(Saved by 0650)

INPUT

1234/4321| Disable/Enable fire alarm signal to release the door

automatically

---|---
1100/1101| Disable/Enable the door monitoring function with

enforce entry and door open too long .

1200/1201| Disable/Enable the security function with enforce
1500| Not compare individual personal map.
1501| Compare individual personal map.
1502| Not compare and add card by reading.
1600/1601| Not compare/ Compare personal time zone map.
1700| Immediately check APB (anti-pass back)
1800/1801| Not compare/ compare holiday.
1900/1901| Not compare/ compare project number. ( for p p p . c c c c c format only)

OUTPUT



21tt

| tt: Door release time from 01 to 97 in unit of 1

second.

2198: Setting door release time becomes minute unit, press 2198 again, door release time back to second unit.

2199: Output becomes normality, both on or off to switch.

---|---
22tt| Alarm time. tt= 00 to 98 in unit of 1 second.



23tt

| tt: Door monitoring time from 01 to 98 in unit of 1

second.

2399: Setting door monitoring time becomes minute

unit, press 2399 again, door monitoring time back to

second unit.

240n| Trial error alarm, n= error times.
25tt| tt:display time from 01 to 97 in unit of 1 second.
2600/2601| Disable/ enable expiry date check (validity date programmed by PC only).
2700| Display fix duty name by ROM.
2701| Definable duty name by PC.
---|---
2702/04/08| 2/ 4/ 8 digit duty name.
2801| Enable bell alarm mode (Trade-off with 1101).
2900| Disable ESD function.(Optioinal)
2901| Enable staff Nr. Display.(Trade-off with 2601,1701-1703)
2902| Enable ESD function. (Optioinal)

OPERATION MODES

3200 Card only mode
3300 Card + PIN mode
3301 External reader needs to press PIN too(for 3300 mode)
3400 Disable 3401/3402
3401 Enable card No.+ PIN code key only mode by keying.

(Press * + card No.+ PIN code)

3402| Enable door PIN mode.(Press 7 + PIN code)
3500/3501| Unlock/Lock the keypad

Unlock keypad by : Press 0 for 5 seconds, after hear beep sound press 0246890 F4=3500 to unlock keypad.

3600| Disable 3601/3602
3601| Enable duress code for card No.+PIN
3602| Enable duress code for door PIN
Note: +1 or -1 of independent pass code, the door will be unlocked and trigger to Alarm system.

Ex.If the door pin is set up as 1234, the duress code will be 1233 or 1235.

3700| Delete the project number by direct reading card
370n| Record the project number by direct reading card for comparing project number

(9806/9816 format only)

3800 Disable all following 3801, 3802, 3803 modes
3801 Enable free access modes
3802 Enable auto duty (shift) code mode
3803 Enable automatic operation mode

Only one mode among 3801, 3802, 3803 is allowed
3900/ 3901| Disable/ Enable Anti-passback mode

DOOR OR MASTER PIN SETTING

460 Set the master PIN for Pongee APP system.
4601~4607 Set the 4 digits door PIN (Under F4=3402)
4609 Set the 6 digits master PIN for system login.
4610~4699 Adding 90 codes 4 digits door PIN (Under F4=3402)
4700 Clear all PINs
4710~4799 Delete the corresponding PIN

CARD INQUIRY

5333 Inquiry card status by reading card ( learning mode)
5500 Inquiry card status for block ragne

TIME ZONES OR FLOORS SETTING MODE/ADDING CARD BY LEARING OR BLOCK RANGE

62nn| Setting time zone for group (nn=01~99,)(Under

F=1601)(P.17)

---|---
Note:Please delete all group data for first time setting group. (F4=0072)
6333| Add single card reading learning mode(P.17)
66nn| Add card with block mode(P.17)

CARD DELETING

  • 72nn: Delete time zone from group nn(nn=01~99) (P.17)
  • 7333: Delete single card with auto learning mode (P.17)
  • 77nn: Delete card with block mode(P.17)

SYSTEM CONFIGURATIONS

8300/830t| Not check repeat reading/ Present repeat reading

within t minutes. (t=1~9 minutes)

---|---
840X| 8400 Non-store the error even

8401 Store the error event

8402 Store the event of exit push button

8403 Store the event of error and exit push button

8599| Send out all personal map (for PC on-line test only) by test com
86FS| Serial output
| ****






86

| F(floor)| S(serial output)|



F=0

| ****

Without lift output (for access only)

| S=0| Disable output
S=1| RS-232 output
S=2| RS-485 output
S=3| RS-232/RS-485 output
FS=10 Support 8 floor
FS=23 Support 24 floor
FS=33 Support 48 floor ~64 floor
FS=91 Support 96 floor output(without time zone function)(optional)
8700| Access records save as FIFO(first-in-first-out)

When the data is full, it should be cleared manually or collect by PC. Otherwise reader can not save new recodes

8701| Automatically save records base on FIFO. When the data is full, the oldest record will be

automatically overwritten.

88aa| Set device address as aa for polling.
890n| If n=0, the system is off-line (batch mode)

If n=3, the system is on-line (real-time mode), if

not necessary, we suggest 8900 to shorten the access response time

FACTORY CONFIGURATION

92nn| nn=00~31the modification factor as the RTC is fast nn=32~63 the modification factor as the RTC is slow

Example: as the crystal is faster than 2Hz, then the factor is 21(F4=9221)

---|---
9311| Enable Bluetooth function.(Optional)
9600/9601| Disable/ enable name display
970N| Select the card digits as group index for comparing.
9781| Reverse the Wiegand number for decoding (New

version firmware)

98pd| To define the card display format
P=Format                   d=Card format

P=0       PN format     d=3        p p p . c c c c c, 26bit(3P5C) P=1 PP format d=5      000CCCCC, 35bit, HC

P=2       PN format     d=6        000CCCCC, 26bit P=3       PP format d=8        C1C2C3C4C5C6C7C8,  34 bit

Ex. F4=9803 PN format, p p p . c c c c c, 26bit(3P5C)

9870 / 9870| Mute / Turn on the sound when timing or program

setting by software

Baud rate (factory default    9996=9,600BPS) :
9996| 9,600 bps
9948| 4,800 bps
9924| 2,400 bps
---|---
Ordered before shipping (due to need to change crystal) :
9919| 19,200 bps
9938| 38,400 bps
9891| 10 digits card number

Optional
Simple and easly trouble shooting

Questions concerning the card reader

Symptom 01 : The reader can not read card and get access

  • A.1: To check whether the proximity card is encoded correctly. Either correct project number or card type. .
  • A.2: To check whether the proximity card is legal.
  • A.3:To check if the personal ID is enrolled in the reader by function F6 of card adding.

Symptom 02 : The reader can read card but can not get access

  • A.1: To check if the reader is at 3300 mode (card with code),the reader lit green LED at left and you do not key-in the PIN within the keypad waiting time.
  • A.2: To check if the reader is at 830t mode (unauthorized repeat card within t minutes), if yes, you should try to get access after t minutes. If 830t isn’t the mode you want, then you may change it to 8300 code.

Symptom 03 : The reader can get access (LED displayed ―good‖ or LCD displayed ―—O.K.—―, but the door was not released.

  • A.1: To check if you correctly wire the electrical lock device with the correct power supply.
  • A.2: If the devices are all correctly wired and the wire is well conducted, then hear if the relay is clicked. If yes, then the relay contacts may be damaged. If not click, then the relay driver in the circuit board may be bad or damaged. Please contact with the distributor for repair or replacement.

Wrong message on LCD display:

  1. C.ERR –Illegal card no. A.ERR –Anti-pass back error
  2. ERR –Time zone error P. ERR – Password error
  3. ERR –Project no. error V. ERR –Out of validity date RPT.ER*–Unable to read card repeatedly during the set time by parameter code 830t

Symptom 04: The door was released but the duration is very short A.1—If the door released period is not so long as you set by 21tt,then please check if the door monitoring mode (1100/1)is set as 1101 mode and the door monitoring sensor doesn’t normal closed as the door is held. In such condition, the door release driver will shut off the relay driver once it found the door is opened because the door sensor is left opened. Therefore, please replace the sensor or set the door monitoring mode as 1100 (not monitoring) before you         replace the sensor.

If the door released period is not so long as you set by 21tt, but you have already disabled the door monitoring function by 1100 or although you actuate the door monitoring by code 1101, but the door sensor works normally, then this phoenomena is resulted from the EMI interference from the drivered electrical device usually. If the coil of the door actuator or the external relay doesn’t well protected by a reversed polarity free wheeling diode to suppress the interference for DC voltage driver or a surge absorber for AC voltage driver, the voltage transient pulse will let theCPU hold down or run into disorder or automatic reset and therefore shorten the door released time to around one second.

Symptom 05: The counter can’t be set by F9 counter setting
At first, if the address 880n is properly set. If the system address isn’t properly set (Can be checked by ―0‖ key) or is disturbed, then the reader won’t store the event counter.

Questions concerning the card reader and its on-lined controller
(Any brand of PC or other dedicate controller)

Symptom 01: The Personal Computer can not collect the data string from the reader(s) by standard software package.

  • A.1: At first, for on-lined application, the installer should ultilize the terminal simulation software package such as TELEX,BITCOM etc. to test whether the wiring between the PC (and the Multi-channel controller PCP-832-xx or the RS-422/RS-232C converter or other 3rd partners interfacing devices for networking) and the readers are well connected and the communication parameters are selected correctly. At the same time, each reader should be set the correct parameters, unique reader address for each reader at the same wire cable for address mode by 88nn, 890n or 8900 for batch type or 890t for real time type…, etc. The reader address can definitely not be set the same for any two readers.The installer should be able to judge whether the wiring is correct and solid reliable by viewing the terminal response from each reader.
  • A.2: If the supported PC standard software package for polling mode and through the multi-channel controller PCP-832-xx can set the system time and date, but cannot collect the stored or immediate data, then please check if the Data Terminal Ready (PIN G) is correctly connected with PIN 4 (Non-inverted Data Terminal Ready). At polling mode, if the real time data is ready or the buffer is not empty, then the PIN G should be at low voltage level less than 2.5 VDC. If at above condition but the voltage level is higher than 2.5 VDC at any side, please check if the wiring is correct.

Symptom 02: The Personal Computer can not collect the data string through the linking driver in Clipper

  • A.1 : Please check if the parameters of on-line (Such as 88aa and 890t of F4) are well programmed.
  • A.2: Please check if the reader is connected at COMM1.
  • A.3: Please check if EMM386.EXE in file of CONFIG.SYS is remarked and whether FILE/BUFFERS is opened as stipulated as rem device=C:\windows\EMM386 I=e000-efff noems
  • A.4: Check whether the delay time in software is matched with executing time in the reader. Please adjust the delay time. (It’s better to turn off the TURBO function).
  • A.5: Please check whether TSR subroutine such as for MOUSE driving, FAX modem or Virus detecting program is standing in the memory. Please get rid of them if they exist in the memory.

Appendix

Pegasus-PP-6750V-Series-Dual-Frequency-Time-Attendance-Recorder-FIG-
\(35\)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PEGASUS User Manuals

Related Manuals