The Genie HDMC221V2 is a 2.1MP HD-SDI encapsulated camera with a 3.6mm fixed lens. It features an electronic shutter with digital slow shutter (DSS) and has a minimum illumination level. The camera also has functions like white balance adjustment, D-WDR, auto gain control (AGC), day and night mode, noise reduction, motion detection, privacy mask, image rotation, defog, and sharpness control. It supports OSD control and multiple languages. The camera provides video output and is powered by a power supply. It has a compact and lightweight design.

Product Usage Instructions

  1. Installation
  2. Connect the camera to a monitor using the appropriate cables.
  3. If using RS-485 communication, choose the appropriate type.
  4. OSD Manual
  5. Refer to the function description in the manual for OSD control.
  6. Hidden Menu
  7. To convert SDI output mode:
  * Enter RS485 mode by pressing the [LEFT] [LEFT] [RIGHT] [RIGHT] key.
  * Press the UP/DOWN/LEFT/RIGHT key 3 times for AD-KEY.
  * Select the desired mode by pressing the UP/DOWN/LEFT/RIGHT key:
    * EX-SDI 2.1 (press UP key 5 times)
    * EX-SDI 2.0 (press DOWN key 5 times)
    * HD-SDI (press LEFT key 5 times)
    * EX-SDI 1.0 (press RIGHT key 5 times)
  * Confirm the selection within 30 seconds by checking the ‘YES’ option. Otherwise, the value will return to the previous setting.
  1. RS-485
  2. Refer to the communication specification for RS-485.
  3. For OSD remote control, use PELCO-D or PELCO-P protocol.

Intro Section

Please read this instruction carefully before operating the product and keep it for further reference. All examples and pictures used here are for reference only. The contents of this manual are subject to change without notice.

CAUTION:

  • Do not use this apparatus near water.
  • Clean only with a dry cloth.
  • Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  • Do not install near any heat sources such as radiators, heat registers, stoves, orother apparatus (including amplifiers) that produce heat.
  • To help prevent electric shock, plug the equipment and peripheral power cables into properly polarized or grounded electrical outlets. These cables are equipped with the wide blade or the third prong to ensure proper grounding.
  • Do not use adapter plugs or remove the grounding prong from a cable. If the provided plug does not fit your outlet, consult an electrician.
    1. Ensure that nothing rests on your equipment’s cables and that the cables are not located where they can be stepped on, tripped over, or pinched.
  • Only use attachments or accessories as specified.
  • Only use the equipment with the cart, stand, tripod, bracket, or table that isspecified by the manufacturer or sold with the apparatus. When a cart is used, use caution to prevent the cart from tipping over and to avoid injury.
  • Do not connect or disconnect during lightning storms due to risk of electric shock.
  • If any of the following conditions occur, unplug the equipment from the electrical outlet and replace the part or contact your trained service provider:
  • The power cable, extension cable, or plug is damaged.
  • An object has fallen into the equipment.
  • The equipment has been exposed to water.
  • The equipment has been dropped or damaged.
  • The equipment does not operate correctly when you follow the operating instructions.

NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Introduction

The Genie HDMC221V2 is a 2.1MP HD-SDI encapsulated camera with a 3.6mm fixed lens.

Product Features

  • 1/2.8” Progressive Scan CMOS
  • 1080p (1920×1080) @ 30 (25)fps
  • EX-SDI/HD-SDI/CVBS output
  • Fixed lens 3.6mm
  • Electronic Day & Night
  • WDR, 3D DNR, Defog
  • RS485 or AD KEY
  • 30x30mm Mini square camera

Product Dimensions

Components

  • Camera
  • Mounting bracket
  • Screws (Tapping and M2)
  • Operational manual
  • DIY cable

Mounting Positiongenie-HDMC221V2-2.1MP-HD-SDI-Encapsulated-Camera-With-3
.6mm-Fixed-Lens-FIG-2

Specification





Camera

| Image Sensor| 1/2.8” SONY Exmor R Progressive Scan CMOS
---|---|---


Resolution

| HD-SDI/EX-SDI1.0_2.0_2.1: 1080p @ 30fps (25fps) / 720p @

60fps (50fps) / 720p @ 30fps (25fps) TV out: CVBS NTSC / PAL (720H)

Electronic Shutter| AUTO / FLICKER / MANUAL /(1/30(25)~1/30,000)
Digital Slow Shutter (DSS)| OFF~ x32
Minimum Illumination| 0.2 Lux (F2.0, AGC33dB, DSS:x2)
Lens| 3.6mm, F 2.0, 112.3 (D) x 93.7 (H)x 49.3˚(V) Angle of View
Effective Pixels| 1945(H) x 1097(V)









Functions

| White Balance| AUTO/AUTO EXT/PUSH LOCK/MANUAL
Level| 135.6dB
D-WDR| Off/On
WDR/BLC| OFF/BLC/HLC/WDR
Auto Gain Control (AGC)| OFF~45dB
Day&Night| AUTO/COLOUR/B&W (Electronic D&N)
Noise Deduction| 3D-DNR (OFF/Low/Middle/High)
Motion Detection| OFF/ON (4 Zones)
Privacy Mask| 16 Zones
Image Rotation| OFF/H-FLIP/V-FLIP/HV-FLIP
Defog| OFF/ON(AUTO/MANUAL)
Sharpness| Adjustable (0~10)
OSD Control| Cable JOYSTIC, RS-485 Control (Option)
Language| 8 languages
Video Output| HD-SDI/EX-SDI1.0/EX-SDI2.0/EX-SDI2.1/CVBS




Others

| Power Supply| DC12V (±10%)
Power Consumption| Max.150mA @ DC12V
Temperatue| -10°C~+50°C (Operating)

-20°C~+60°C (Storage)

Dimensions| 30 x 30 mm
Weight| Approx.28.9g (Board lens)

Connection

Basic Specificationgenie-HDMC221V2-2.1MP-HD-SDI-Encapsulated-Camera-
With-3.6mm-Fixed-Lens-FIG-3

OSD Manual

genie-HDMC221V2-2.1MP-HD-SDI-Encapsulated-Camera-With-3.6mm-
Fixed-Lens-FIG-4genie-HDMC221V2-2.1MP-HD-SDI-Encapsulated-Camera-With-3.6mm-Fixed-Lens-
FIG-5

Hidden Menu

Convert SDI Output Mode
STEP 1. ENTER

  • RS485 : Press [LEFT] → [LEFT] → [RIGHT] →[RIGHT] key.
  • AD-KEY : Press UP/DOWN/LEFT/RIGHT key 3 times.

STEP 2. SELECT

  • Press UP key 5 times : EX-SDI 2.1
  • Press DOWN key 5 times : EX-SDI 2.0
  • Press LEFT key 5 times : HD-SDI
  • Press RIGHT key 5 times : EX-SDI 1.0

STEP 3. CONFIRM
If the ‘YES’ is not checked within 30sec, the value returns to the previous setting.

Communication Specificationgenie-HDMC221V2-2.1MP-HD-SDI-Encapsulated-
Camera-With-3.6mm-Fixed-Lens-FIG-6

PELCO Protocol for OSD Remote Control PELCO-D

  • Cam ID : 0x00 ~ Ox1F
  • ChkSum: The Check Sum is the 8 bit (modulo 256) sum of the payload bytes (Byte2 ~ Byte6) in the Command.
  • [0x0A-0x3F] means accept any value(between 0x0A – 0x3F) on command action.

PELCO-P

  • Cam ID: 0x00 ~ Ox1F
  • ChkSum : The Check Sum is an XOR sum of Bytel ~ Byte7
  • [OXOA-0x3F] means accept any value(between OxOA – 0X3F) on command action.
  • Sales +44(0)1707 330541
  • Enquiries sales@genieproducts.co.uk.
  • Website www.genieproducts.co.uk.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals