Blue-White F-461 Variable Area Flow Meters User Guide
- June 13, 2024
- Blue-White
Table of Contents
Quick Start Guide
Polysulfone
Variable Area Flow Meters F-440/F-450/F-451/F-452/F-460/F-461/F-462
IMPORTANT
Safety instructions
CAUTION
Follow these instructions before installing your flow meter to avoid failure.
CAUTION
Always wear eye protection when installing or removing flow meters.
UV WARNING
Do not install the meter in direct sunlight. The meter can be damaged by UV
light.
PRESSURE
Do not exceed maximum pressure. High pressure and temperature will damage the
meter.
PRE-INSTALLATION
Before you begin
In the Box
Flow meter
Quick start guide
Compatibility
Ensure the piping is either straight vertical SCH 40 or SCH 80.
Planning
Mounts and supports must be sturdy enough to support the plumbing and prevent
vibration. Vibration and heavy loads will damage the meter.
Tools Needed
PTFE Tape
Suitability
It is the responsibility of the user to determine the suitability of the flow
meter in their application. Flow meters are tested and calibrated for water
only.
INSTALLATION
Step-By-Step
-
Prepare
The flow meter must be installed in a vertical plane to ensure accuracy. Misalignment may damage the flow meter and also cause the oring seals to leak.
*Minimum acceptable dimensions -
Install
Use only PTFE tape on the threaded adapters. Pipe dope and glue will damage the polysulfone meter body and fittings. Alternatively, install the flow meter after all glued fittings have dried and fumes have been purged from the system. -
Read
Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force. Read float at the top or at the widest diameter.
CARING
For your flow meters
Cleaning
The tapered tube may be cleaned with a soft bottle brush.
Use a MILD soap and water solution for cleaning purposes.
Note the floats “up” position for re-assembly.
WARRANTY
Information
LIMITED WARRANTY
Your Blue-White product is a quality product and is warranted for a specific
time from the date of purchase (proof of purchase is required). The product
will be repaired or replaced at our discretion. Failure must have occurred due
to a defect in material or workmanship and not as a result of the operation of
the product other than in normal operation as defined in the product manual.
Warranty status is determined by the product’s serial label and the sales
invoice or receipt. The serial label must be on the product and legible. The
warranty status of the product will be verified by Blue-White or a factory-
authorized service center.
Variable Area and Digital Flow meters are warranted for 1 year from the date
of purchase (proof of purchase is required). The flow meter will be repaired
or replaced at our discretion.
WHAT IS NOT COVERED
- Freight to the factory, or service center.
- Products that have been tampered with, or in pieces.
- Damage resulting from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control.
- Damage by faulty wiring, power surges, or acts of nature.
- Damage that occurs as a result of: meter misalignment, improper installation, over tightening, use of non-recommended chemicals, use of non-recommended adhesives or pipe dopes, excessive heat or pressure, or allowing the meter to support the weight of related piping.
BLUE-WHITE does not assume responsibility for any loss, damage, or expense
directly or indirectly related to or arising out of the use of its products.
Failure must have occurred due to a defect in material or workmanship and not
as a result of the operation of the product other than in normal operation as
defined in the manual.
Warranty status is determined by the product’s serial label and the sales
invoice or receipt. The serial label must be on the product and legible. The
warranty status will be verified by Blue-White or a factory-authorized service
center.
PROCEDURE FOR IN-WARRANTY REPAIR
Warranty service must be performed by the factory or an authorized service
center. Contact the factory or local repair center to obtain a RMA (Return
Material Authorization) number. It is recommended to include a foot strainer
and injection/check valve fitting since these devices may be clogged and part
of the problem. Decontaminate, dry, and carefully pack the product to be
repaired. Please enclose a brief description of the problem and proof of
purchase. Prepay all shipping and insurance costs. COD shipments will not be
accepted. Damage caused by improper packaging is the responsibility of the
sender. When In-Warranty repair is completed, the factory pays for return
shipping to the dealer or customer.
Have Questions?
Contact us +1 714-893-8529
customerservice@blue-white.com
blue-white.com/contact-us
P.N. #80000-703 REV 0.9 20220511
ISO 9001:2015 CERTIFIED
MADE IN THE USA