IMPORTANT Safety instructions
| CAUTION
Follow these instructions before installing your flow meter to avoid failure.
---|---
| CAUTION
Always wear eye protection when installing or removing flow meters.
| LOCATION
Meters are suitable for indoor and outdoor use.
| PRESSURE
Do not exceed 75 PSI (5.17 bar).
High pressure and temperature will damage the meter.
PRE-INSTALLATION Before you begin
In the Box
Flow meter Quick start guide
Tools Needed
PTFE Tape
Compatibility
Ensure the piping is either straight vertical SCH 40 or SCH 80.
Planning
Mounts and supports must be sturdy enough to support the plumbing and prevent
vibration.
Vibration and heavy loads will damage the meter.
Suitability
It is the responsibility of the user to determine the suitability of the flow
meter in their application.
Flow meters are tested and calibrated for water only.
INSTALLATION Step-By-Step
-
Prepare
The flow meter must be installed in a vertical plane to ensure accuracy. Misalignment may damage the flow meter and also cause the oring seals to leak.
*Minimum acceptable dimensions -
Install
Use only PTFE tape on the threaded adapters.
Pipe dope and glue will damage the polysulfide meter body and fittings. Alternatively, install the flow meter after all glued fittings have dried and fumes have been purged from the system. -
Read
Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force.
Read float at the top or at the widest diameter.
CARING For your flow meters
Cleaning
The tapered tube may be cleaned with a soft bottle brush.
Use a MILD soap and water solution for cleaning purposes.
Note the floats “up” position for re-assembly.
WARRANTY Information
LIMITED WARRANTY
Your Blue-White product is a quality product and is warranted for a specific
time from the date of purchase (proof of purchase is required).
The product will be repaired or replaced at our discretion. Failure must have
occurred due to a defect in material or workmanship and not as a result of the
operation of the product other than in normal operation as defined in the
product manual.
Warranty status is determined by the product’s serial label and the sales
invoice or receipt. The serial label must be on the product and legible.
The warranty status of the product will be verified by Blue-White or a
factory-authorized service center.
Variable Area and Digital Flow meters are warranted for 1 year from the date
of purchase (proof of purchase is required). The flow meter will be repaired
or replaced at our discretion.
WHAT IS NOT COVERED
- Freight to the factory, or service center.
- Products that have been tampered with, or in pieces.
- Damage resulting from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control.
- Damage by faulty wiring, power surges, or acts of nature.
- Damage that occurs as a result of: meter misalignment, improper installation, over tightening, use of non-recommended chemicals, use of non-recommended adhesives or pipe dopes, excessive heat or pressure, or allowing the meter to support the weight of related piping.
BLUE-WHITE does not assume responsibility for any loss, damage, or expense
directly or indirectly related to or arising out of the use of its products.
Failure must have occurred due to a defect in material or workmanship and not
as a result of the operation of the product other than in normal operation as
defined in the manual.
Warranty status is determined by the product’s serial label and the sales
invoice or receipt. The serial label must be on the product and legible. The
warranty status will be verified by Blue-White or a factory-authorized
service center.
PROCEDURE FOR IN-WARRANTY REPAIR
Warranty service must be performed by the factory or an authorized service
center. Contact the factory or local repair center to obtain a RMA (Return
Material Authorization) number.
It is recommended to include a foot strainer and injection/check valve fitting
since these devices may be clogged and part of the problem. Decontaminate,
dry, and carefully pack the product to be repaired. Please enclose a brief
description of the problem and proof of purchase.
Prepay all shipping and insurance costs. COD shipments will not be accepted.
Damage caused by improper packaging is the responsibility of the sender. When
In-Warranty repair is completed, the factory pays for return shipping to the
dealer or customer.
1.888.610.7664
www.calcert.com
sales@calcert.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>