Blue-White MS6 Chemical Feed Flow Meter User Guide
- June 13, 2024
- Blue-White
Table of Contents
Quick Start Guide MS6
SONIC-PRO® Chemical Feed Flow Meter
IMPORTANT
Safety instructions
| Follow these instructions before installing your flow meter to avoid
failure.
---|---
| The MS6 is designed to be installed and operated by qualified personnel
only.
Please note that warranty coverage does not include damage due to misuse or
improper installation.
| Always wear eye protection when installing or removing flow meters.
| Confirm chemicals being used with MS6 flow meter are compatible with wetted
components of the flow meter.
| Do not exceed maximum pressure. High pressure and temperature will damage
the meter.
PRE-INSTALLATION
Before you begin
In the Box
- MS6 Chemical feed flow meter
- Meter Body Connection Fittings
- 3/16” Hex Key
- Flash Drive(Operating Manual and Blue-Central®)
- USB-A to USB-C Connector
- Power Supply(User configurable)
- Quick Start Guide
Tools Needed
1/32” Mesh strainer
Planning
Mounts and supports must be sturdy enough to support the plumbing and prevent
vibration. Vibration and heavy loads will damage the meter.
Wiring
To access the wiring terminal, open the enclosure by removing the four screws
with the provided 3/16” hex key. The meter must be powered by 5 volts DC.
Wattage must not exceed 5 watts. 20-24 AWG(American Wire Gurage) shielded
cable is recommended for signal output connections.
The MS6 wiring compartment is equipped with two communications cable liquid-
tight cable glad grommets for cable diameters from .190 to .205 inches. Refer
to page 21, section 11 of the provided Operating Manual for details.
Maintenance
When the MS6 Flow meter is removed from the system or an empty pipe condition
causes the meter to dry out, always flush the meter with water before
reinstalling.
INSTALLATION
Step-By-Step
-
Install Blue-Central® Blue-Central®
is Blue-White’s proprietary software application that allows the user to update firmware and view the meter’s device details. To configure the MS6, Blue-Central® must be installed and running on a desktop or laptop computer. Insert the provided USB Flash Drive, and open the .exe file to install and run the Blue-Central® application. -
Connect
Connect the meter to the desktop or laptop computer with the provided USB to USB-C cable. The meter will appear on the Blue-Central® dashboard (may take up to 30 seconds). -
Configure
It is suggested that the user configures its operating parameter in advance. The meter will work without performing a configuration, however, the default settings may not be adequate for the required application. For assistance in configuring the meter, refer to the provided Operating Manual (page 7, section 6.0) located on the USB. -
Install in an upward direction
The flow meter must be installed in a vertical plane with fluid flowing in an upward direction to ensure accuracy. To reduce large particles and bubbles that can reduce signal quality, it is recommended that a 1/32” mesh strainer is installed at the inlet of the meter. Ensure all o-rings are in place and properly seated. -
Calibrate
After installation, and the MS-6 can be calibrated and finetuned to provide the best accuracy for your dosing rate.
With solution running through the flowmeter, re-connect to the computer with Blue-Central® , and perform a Digital Drawdown. Follow directions in Section 9.0 of the Operating Manual for best results.
WARRANTY
Information
LIMITED WARRANTY
Your Blue-White product is a quality product and is warranted for a specific
time from the date of purchase (proof of purchase is required).
The product will be repaired or replaced at our discretion. Failure must have
occurred due to a defect in material or workmanship and not as a result of the
operation of the product other than in normal operation as defined in the
product manual. Warranty status is determined by the product’s serial label
and the sales invoice or receipt. The serial label must be on the product and
legible. The warranty status of the product will be verified by Blue-White or
a factory authorized service center.
MS6 are warranted for 5 years from the date of purchase.
WHAT IS NOT COVERED
- Freight to the factory, or service center.
- Products that have been tampered with, or in pieces.
- Damage resulting from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control.
- Damage by faulty wiring, power surges, or acts of nature.
- Damage that occurs as a result of: meter misalignment, improper installation, over tightening, use of non-recommended chemicals, use of non-recommended adhesives or pipe dopes, excessive heat or pressure, or allowing the meter to support the weight of related piping.
BLUE-WHITE does not assume responsibility for any loss, damage, or expense
directly or indirectly related to or arising out of the use of its products.
Failure must have occurred due to a defect in material or workmanship and not
as a result of the operation of the product other than in normal operation as
defined in the manual.
Warranty status is determined by the product’s serial label and the sales
invoice or receipt. The serial label must be on the product and legible.
The warranty status will be verified by Blue-White or a factory-authorized
service center.
PROCEDURE FOR IN-WARRANTY REPAIR
Warranty service must be performed by the factory or an authorized service
center. Contact the factory or local repair center to obtain a RMA (Return
Material Authorization) number.
It is recommended to include a foot strainer and injection/check valve fitting
since these devices may be clogged and part of the problem.
Decontaminate, dry, and carefully pack the product to be repaired. Please
enclose a brief description of the problem and proof of purchase.
Prepay all shipping and insurance costs. COD shipments will not be accepted.
Damage caused by improper packaging is the responsibility of the sender. When
In-Warranty repair is completed, the factory pays for return shipping to the
dealer or customer.
P.N. #80000-602 MS6 QSG REV 10 20220725
150 9001:2015
CERTIFIED
MADE IN
USA
Have Questions?
Contact us
+1 714-893-8529
customerservice@blue-white.com https://www.blue-white.com/contact-us/
Documents / Resources
|
Blue-White MS6 Chemical Feed Flow
Meter
[pdf] User Guide
MS6 Chemical Feed Flow Meter, MS6, Chemical Feed Flow Meter, Feed Flow Meter,
Flow Meter, Meter
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>