Blue-White F-430 Acrylic Flowmeter Instruction Manual
- June 13, 2024
- Blue-White
Table of Contents
F-430 Flowmeter
Instruction Manual
Your Blue-White® F-430 Series In-Line Flowmeter
This flowmeter was designed to be easily installed. Please read this
Instruction guideline before installing your flowmeter.
Note: Plastic tubing inserted into flowmeter is used to prevent damage during
shipping.
Remove before installing.
ISO 9001:2015
CERTIFIED
Installation Guideline
- The flowmeter must be installed in a vertical plane to ensure accuracy. Misalignment may damage the flowmeter and also may cause the o-ring seals to leak.
- Use only PTFE tape on the threaded adapters. Pipe dope and glue will damage the polysulfone meter body and fittings. Or install the flowmeter after all glued fittings have dried and fumes have been purged from the system.
- Mounts and supports must be sturdy enough to support the plumbing and prevent vibration. Vibration and heavy loads will damage the meter.
- Avoid imposing a sudden burst of flow to the meter. Solenoid valves will damage the meter. Such a burst will cause the float to impact the top float stop with destructive force.
- The Maximum fluid temperature is dependant on the working pressure. High pressure and temperature with damage the meter. (see temperature VS pressure chart)
TEMPERATURE vs PRESSURE
Temperature
F-430
EXPLODED VIEW, PARTS LIST AND SPECS
EXPLODED VIEW
PARTS LIST
Item | Catalog No. | Description | Qty |
---|---|---|---|
1 | 76001-226 | 1.5″ male NPT adapter (PVC) | 2 |
1 | 76001-216 | 2″ male NPT adapter (PVC) | 2 |
2 | 90003-118 | 0-ring (Viton)* | 2 |
3 | 91001-198 | Wire Holder (PSF) | 2 |
4 | 90003-140 | 0-ring (Aflas)* | 2 |
5 | – | Float (SS) | 1 |
6 | 76001-229 | Guidewire (SS) | 1 |
7 | – | Meterbody (Acrylic) | 1 |
Shading indicates item not sold separately
*EP Option Available
PSF= polysulfone
SS = # 316 Stainless Steel
PVC = Polyvinyl chloride
METER SPECS
Scale | Permanent dual scale silkscreen |
---|---|
Max Pressure | See Temperature vs. Pressure chart* |
Max Temperature | See Temperature vs. Pressure chart* |
Height | 14″ (355.6 mm) |
Width | 3″ (76.2 mm) |
Accuracy | ± 5% of full scale reading |
APPLICATION NOTES
Although meters may be suitable for other chemicals, Blue-White cannot
guarantee their suitability. It is the responsibility of the user to determine
the suitability of the flowmeter in their application. Flowmeters are tested
and calibrated for water only.
MAINTENANCE
The “Exploded View” drawing illustrates assembly of the F-430 series meter.
If your flowmeter needs to be cleaned refer to this drawing when reassembling
the unit. The tapered tube may be cleaned with a soft bottle brush. Use a MILD
soap and water solution for cleaning purposes. Note the float’s “up” position.
BLUE-WHITE LIMITED WARRANTY
Your Blue-White product is a quality product and is warranted for a specific time from date of purchase (proof of purchase is required). The product will be repaired or replaced at our discretion. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the product manual. Warranty status is determined by the product’s serial label and the sales invoice or receipt. The serial label must be on the product and legible. The warranty status of the product will be verified by Blue-White or a factory authorized service center.
Variable Area and Digital Flow meters are warranted for 1 year from date of purchase (proof of purchase is required). The flow meter will be repaired or replaced at our discretion. The S6A ultrasonic flow meter is warranted for 2 years from date of purchase (proof of purchase is required). The flow meter will be repaired or replaced at our discretion.
WHAT IS NOT COVERED
- Freight to the factory, or service center.
- Products that have been tampered with, or in pieces.
- Damage resulting from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control.
- Damage by faulty wiring, power surges or acts of nature.
- Damage that occurs as a result of: meter misalignment, improper installation, over tightening, use of non-recommended chemicals, use of non-reccomended adhesives or pipe dopes, excessive heat or pressure, or allowing the meter to support the weight of related piping.
BLUE-WHITE does not assume responsibility for any loss, damage, or expense
directly or indirectly related to or arising out of the use of its products.
Failure must have occurred due to defect in material or workmanship and not as
a result of operation of the product other than in normal operation as defined
in the manual.
Warranty status is determined by the product’s serial label and the sales
invoice or receipt. The serial label must be
on the product and legible. The warranty status will be verified by Blue-White
or a factory authorized service center.
PROCEDURE FOR IN WARRANTY REPAIR
Warranty service must be performed by the factory or an authorized service
center. Contact the factory or local repair center to obtain a RMA (Return
Material Authorization) number. It is recommended to include foot strainer and
injection/check valve fitting since these devices may be clogged and part of
the problem. Decontaminate, dry, and carefully pack the product to be
repaired. Please enclose a brief description of the problem and proof of
purchase. Prepay all shipping and insurance cost. COD shipments will not be
accepted. Damage caused by improper packaging is the responsibility of the
sender. When In-Warranty repair is completed, the factory pays for return
shipping to the dealer or customer.
PRODUCT USE WARNING
Blue-White products are manufactured to meet the highest quality standards
in the industry. Each product instruction manual includes a description of the
associated product warranty and provides the user with important safety
information. Purchasers, installers, and operators of Blue-White products
should take the time to inform themselves about the safe operation of these
products. In addition, Customers are expected to do their own due diligence
regarding which products and materials are best suited for their intended
applications. BLUE-WHITE is pleased to assist in this effort but does not
guarantee the suitability of any particular product for any specific
application as Blue-White does not have the same degree of familiarity with
the application that the customer/end user has. While BLUE-WHITE will honor
all of its product warranties according to their terms and conditions, Blue-
White shall only be obligated to repair or replace its defective parts or
products in accordance with the associated product warranties.
BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.
CHEMICAL RESISTANCE WARNING
BLUE-WHITE offers a wide variety of wetted parts. Purchasers, installers,
and operators of Blue-White products must be well informed and aware of the
precautions to be taken when injecting or measuring various chemicals,
especially those considered to be irritants, contaminants or hazardous.
Customers are expected to do their own due diligence regarding which products
and materials are best suited for their applications, particularly as it may
relate to the potential effects of certain chemicals on Blue-White products
and the potential for adverse chemical interactions. Blue-White tests its
products with water only. The chemical resistance information included in this
instruction manual was supplied to BLUE-WHITE by reputable sources, but Blue-
White is not able to vouch for the accuracy or completeness thereof. While
BLUE-WHITE will honor all of its product warranties according to their terms
and conditions, Blue-White shall only be obligated to repair or replace its
defective parts or products in accordance with the associated product
warranties.
BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS
OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING
OUT OF OR RELATED TO THE USE OF CHEMICALS IN CONNECTION WITH ANY BLUE-
WHITE PRODUCTS.
Users of electrical and electronic equipment (EEE) with the WEEE marking
per Annex IV of the WEEE Directive must not dispose of end of life EEE as
unsorted municipal waste, but use the collection framework available to them
for the return, recycle, recovery of WEEE and minimize any potential effects
of EEE on the environment and human health due to the presence of hazardous
substances. The WEEE marking applies only to countries within the European
Union (EU) and Norway. Appliances are labeled in accordance with European
Directive 2002/96/EC. Contact your local waste recovery agency for a
Designated Collection Facility in your area.
URL: www.Blue-White.com
E-mail: sales@blue-white.com
Customerservice@blue-white.com
Phone: 714-893-8529
Fax: 714-894-0149