MEAN WELL DCW1 2 Series 12W DC DC Regulated Dual Output Converter Owner’s Manual

June 13, 2024
MEAN WELL

MEAN WELL DCW1 2 Series 12W DC DC Regulated Dual Output Converter Owner’s Manual
Series 12W DC DC Regulated Dual Output

Features:

  • 2:1 wide input range
  • 1500VDC I/O isolation
  •  Built-in remote ON/OFF control
  • Built-in EMI filter
  • Protections: Short circuit / Overload
  • Cooling by free air convection Five-sided shield metal case
  • 100% full load burn-in test Low cost/High reliability
  • 2 years warranty

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

ORDER NO.| DCW12A-05| DCW12B-05| DCW12C-05| DCW12A-12| DCW12B-12| DCW12C-12| DCW12A-15| DCW12B-15| DCW12C-15
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| ±5V| ±12V| ±15V
CURRENT RANGE| ±240 – ±1200mA| ±100- ±500mA| ±80 – ±400mA
RATED POWER| 12W
RIPPLE & NOISE (max.) Note.2| 50mVp-p| 60mVp-p| 60mVp-p
LINE REGULATION Note.3| ±0.5%
LOAD REGULATION              Note.4| ±0.5%
VOLTAGE ACCURACY| ±2 0%
SWITCHING FREQUENCY| 400KHz min.
EXTERNAL CAPACITANCE LOAD| (max.)| 670uF| 1100uF| 47uF
INPUT| VOLTAGE RANGE| A: 9 – 18VDC     B: 18 – 36VDC          C: 36 – 72VDC
EFFICIENCY (Typ.)| 80%| 80%            181%    184%| 84%| 84%| 83%| 84%| 83%
DC CURRENT| Full load| A: 1245mA      B: 625mA   C: 320mA
No load| A: 70mA      B: 35mA     C: 25mA
FILTER| Pi network
PROTECTION| Fuse recommended
PROTECTION Note.5| OVERLOAD| 110 – 180% rated output load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT| All output equipped with over current protection
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| -40 – +71°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| 40 +105°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.05% / –C    (0 – 50°C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & **EMC| SAFETY STANDARDS| EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE| I/P-0/P:1.5KVDC
ISOLATION RESISTANCE| I/P-0/P: 100M Ohms / 500VDC / 25cC/ 70% RH
ISOLATION CAPACITANCE| 2200pF max.
EMC EMISSION| Compliance to BS EN/EN55032 Class A, FCC part 15 Class A, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020
OTHERS| REMOTE CONTROL| Power ON: R.C. – -yin > 4VDC or open ; Power OFF: R.C. – -yin < 1VDC or short
MTBF| 600Khrs min. MIL-HDBK-217F (25°C)
DIMENSION| 31.820.312.2mm (LWH) or 1.25″0.80″0.48″ inch (LWH)
PACKING**| 17.5g ; 15pcs/per tube, 750pcs/50 tube/per carton

Mechanical Specification

Unit: mm(inch)
Dimension
Pin Size is Tolerance 0.5±0.05mm, Tolerance .X or .XX= ±0.5mm

Pin Configuration

Pin No . Output
1 R.C.
2 & 3 -Vi n
9 CO M
11 -Vo u t
1 4 +Vo u t
16 CO M
2 2 & 23 + Vi n

Derating Curve

LOAD (%)
Dimension
Ta (℃)

NOTE

  1. All parameters are specified at normal input, rated load, 25°C 70% RH ambient.
  2.  Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1uf & 47uf capacitor.
  3. Line regulation is measured from low line to high line at rated load.
  4. Load regulation is measured from 20% to 100% rated load.
  5. Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.

12W DC-DC Regulated Dual Output Converter

Packing

Standard Tube Packing| MPQ Per Tube (PCS)| One Box G.W.| Max. Q’TY/ Carton(PCS)| One Carton G.W.
---|---|---|---|---
Unit : mm
Tube Plugs
Tube pattern

CARTON
CARTON L600 x W230 x H220

| 15| 313g| 750| 17Kg

CE Mark

Installation Manual Please refer to : http://www.meanwell.com/manual.html
File Name: DCW12-SPEC 2022-05-24

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>