CORBETT 434-18-VGL Coralie 4 Light Chandelier Instruction Manual
- June 13, 2024
- CORBETT
Table of Contents
CORBETT 434-18-VGL Coralie 4 Light Chandelier
Product Information
The product is a lighting fixture manufactured by Hudson Valley Lighting Group. It is part of the Corbett Collection and the model name is Coralie-8. The package includes various parts such as canopy, chain, metal decorations, and Capiz decorations. The product is designed for installation in a fixed location.
Product Usage Instructions
- Fix the crossbar (A) using the mounting screws (B).
- Attach the screw collar (I) to the collar loop (H).
- Connect the nipple (C) to the collar loop (H).
- Secure the nipple (C) using the hex nut (E) and tooth washer (D).
- Attach the canopy (J) to the crossbar (A).
- Use the chain (K) to connect the fixture assembly (L) to the canopy (J).
- Fasten the screw collar (I), canopy (J), collar loop (H), nipple (C), and crossbar (A) together.
- Ensure proper grounding by connecting the ground screw (F) to the crossbar (A). Never connect the ground wire to the hot wire to avoid serious injury or death.
- Connect the wires following the instructions for SPT N (SPT wire with no writings) and SPT W (SPT wire with writings). Make sure there are no exposed wires or strands that could cause a dangerous short circuit. Never reverse hot and neutral wires to avoid serious injury or death.
- Attach the canopy (J) and screw collar (I) to the collar loop (H).
- Install the bulb (O) in the socket. The fixture is rated for an 8-watt type B lamp. Do not exceed the recommended wattage
- Add the Capiz decorations (N) and metal decorations (M) to the fixture assembly (L).
- Connect the fixture to the power outlet.
Please refer to the provided part numbers for replacements or additional hardware: HDW-CPY-8, CHN-8, DEC-M, DEC-C.
WARNING/CAUTION
- DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
- TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
- CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
- UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS. · PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.
INSTALLATION
PART(S) | REPLACEMENT PART NAME | NUMBER |
---|---|---|
A,B,C,D,E,F,G,H,I | HARDWARE KIT | HDW-434-14 |
J | CANOPY | CPY-434-18 |
K | CHAIN | CHN-434-18 |
M | METAL DECORATIONS | DEC-434-14M |
N | CAPIZ DECORATIONS | DEC-434-14C |
FIXTURE INSTALLATION
-
Attach the CROSSBAR (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
-
Remove the SCREW COLLAR (I) from the COLLAR LOOP (H). Fully thread the NIPPLE (C) onto the COLLAR LOOP (H). Thread the HEX NUT (E) onto the NIPPLE (C) along with TOOTH WASHER (D). Then thread the NIPPLE (C) onto the CROSSBAR (A). Adjust the NIPPLE (C) so that the threads of the COLLAR LOOP (H) extends 1/4″ beyond the CANOPY (J). Secure using HEX NUT (E).
-
Open the end link the of the CHAIN (K) and attach to the FIXTURE ASSEMBLY (L) at the desired height. Slide the SCREW COLLAR (I) and the CANOPY (J) onto the CHAIN (K). Open the link on other end of the CHAIN (K) then attach unto the COLLAR LOOP (H). Feed the wires through the CHAIN (K) , SCREW COLLAR (I), CANOPY (J), COLLAR LOOP (H), NIPPLE (C), and CROSSBAR (A).
-
Cut off excess wires, and strip the insulation off the end of the leads.
-
Attach the Ground wire to the ground inside the junction box (Generally green or bare copper wire) or the GROUND SCREW (F) on the CROSSBAR (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE!FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
-
Connect the fixture’s SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (G).
Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT! -
Connect the fixture’s SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
-
Push the wires back into the junction box. Lift up the CANOPY (J) up to the ceiling, and screw the SCREW COLLAR (I) onto the COLLAR LOOP (H).
-
Screw the BULB (O) up into the SOCKET of the FIXTURE ASSEMBLY (L). THIS FIXTURE IS RATED FOR 8 WATT TYPE B LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
-
Attach the CAPIZ DECORATIONS (N) onto the FIXTURE ASSEMBLY (L) by inserting its clips in the
holes. -
Attach the METAL DECORATIONS (M) onto the FIXTURE ASSEMBLY (L).
-
Restore power to the OUTLET at the breaker or fuse box.