Drainspexx
User Guide
Drainspexx Unit for Advanced Drain Disinfection
- The device must only be operated by instructed operators.
- Follow the use instructions delivered with the device.
- Always wear suitable Personal Protective Equipment.
- Never direct the fogging nozzle towards humans, animals or electric installations.
- Only suitable for drain disinfection.
- The only biocides allowed are:
1. Kenolox 10
2. Aseptanios AF 310
Availability ma depend on government approvals in the individual country. Do NOT mix 2 different biocides.
Layout
Esquema
Safety
Wear appropriate PPE
- Working boots class S2.
- Safety glasses.
- Gloves and suitable clothing.
Attention: Do not use scratched or damaged hoses!
Pre cleaning
Drainspexx is to be used in cleaned drains only.
Biocide can and Spray bottle
- Place biocide can (i) in the Drainspexx unit.
- Place the suction lance in the can opening.
- Always have a spray bottle filled with fresh Biocide.(ii)
- Drive trolley to the first drain to be treated.
Air connection
Connect pressurized air tube using quick joint. (i)
Attention: Pressure at the Drainspexx unit should be 6 bar. (ii)
At the drain
- Remove drain cover. (i)
- Remove sieve from drain. (ii)
- Remove siphon insert. (iii)
- One of the drain adaptors will be applicable to the round drain pipe opening. (i)
- Check if drain is blocked.
Attention: If you find the drain blocked, do not apply.
Adapter selection
Easy to insert in cylindrical drain line. Select appropriate adapter according
to diameter.
Screw the adapter on the nozzle.
Attention: Check adapter lips for any damage and correct sealing.
In case of damage, do not use further!
Check for tight fitting to the drain line wall, note that 2 lips (upper or
lower) must seal the drain line.
Start/Stop fogging
- Open air valve at Drainspexx unit (turn handle 90 °).
- Check noise of nozzle. (If no noise appears, check air supply).
- Open biocide valve, fogging starts.
- Apply for 3 min.
- Finally close valves, remove adapter.
Avoid x-contamination
- Use spray bottle filled with Biocide to disinfect the adapter.
- Spray Biocide onto the surfaces of the drain pipe entrance where the adapter was placed during Drainspexx application.
- After applying Drainspexx to a drain, make sure that the siphon is reinstalled into the drain, in such way that it fulfills its intended purpose.
- Reinsert sieve and cover.
Disconnecting of Drainspexx
- Disconnect air supply
- Hang up the rolled-up air tube and the other tubes at the Drainspexx unit.
10 Move to the next drain to conduct the treatment
No.: 110008363C 08/22
Printed in Denmark