TMC Blue Belle Chic/To Free Flame Heater Instruction Manual
- June 8, 2024
- TMC
Table of Contents
Belle Chic/To Free Flame Heater
Instruction Manual
BLUE BELLE CHIC/TO
Keep this manual for future reference. Original in Italian.
SOBTO.GB
(31.10.22)
This stove uses liquefied petroleum gas: the LPG cylinders are suitable for
indoor use.
The use of other fuels or of cylinders not indicated in this manual is
forbidden.
Do not store or use petrol or other flammable liquids or vapours in the
vicinity of this or other appliances. Servicing must be carried out by a
qualified technician.
This is a heating system. It uses the air (oxygen) of the room in which it is
installed. Adequate arrangements must be provided for combustion and
ventilation. Refer to the WARNING AND SAFETY SECTIONS indicated by the symbol:
Warning!
Warning: failure to comply with the information given in this manual may
result in fire or explosions that may damage properties and injure people and
animals.
Important warning!
This icon indicates that the instructions on correct appliance use must be
complied with. This will prevent any malfunction.
Important information!
This icon indicates information and recommendations that ensure that the
appliance is correctly used. These instructions were written with the utmost
care. However, the manufacturer reserves the right to improve this manual at
any time and in any way they may deem suitable. Images may differ from the
original appliance.
TECHNICAL SPECIFICATIONS
DESTINATION: | GB – IE |
---|---|
TYPE OF GAS AND PRESSURE: | Butane 28 mbar |
Category: | I3B |
Rated power: | 4.2 kW(Hs) |
Max consumption: | 0.3 kg/h |
DVGW registration number: | CE-0085BM0301 |
Read the instructions carefully before using the appliance.
The appliance is not intended to be used by people (children included) with
reduced physical, sensory or mental abilities, or without the necessary
experience and knowledge, unless they have been instructed on the use of the
appliance. Children must not be permitted to play with the appliance.
Please observe the safety instructions:
The appliance should be operated only if there is adequate ventilation! The
appliance must be used in compliance with the current local, regional and
national regulations.
Introduction
Dear Customer,
Thank you for purchasing your blue flame stove! You made an excellent choice
and we are honoured that you placed your trust in us. Before using your stove,
please read this manual carefully. In the following pages you will find some
important information: it is very important that you read this manual before
using your new gas stove and that you keep it handy for the whole time your
stove is in operation.
The open fire stove model Blue Belle does not vent gas and can only be used in
a domestic environment. The fuel used for the stove is a non-polluting liquid
gas: propane-butane. This appliance received approval by the German
certification body DVGW and complies with Gas European appliance regulation
2016/426/EU. This stove is tested according to EU gas regulation as well as to
EN 449 and complies with the strictest safety regulations currently in force.
This naked flame stove is an ideal and cost-effective
solution for your rooms as it represents an additional heating source. It is
also ideal for use in autumn and spring.
Product description
2.1 General guidelines
Gas stoves by TMC guarantee high heating power and low consumptions together
with a constant distribution of heat which in turn leads to a more efficient
use of energy as well as lower toxic emissions.
2.2 Scope of application and intended use
The gas stove complies with the required technical and safety standards.
However, an improper or incorrect use may be hazardous for the life or the
physical safety of users or thirds, and may damage the device, property or
animals.
This stove generates heat by using gas. The burner produces a flame that heats
up the air which, thanks to the conductive effect, heats up the room where the
stove is installed. For appliances without a thermostat, heat is adjusted
manually (there are two power levels), whereas for appliances fitted with a
thermostat, the heat is adjusted automatically, and the stove is switched off
once the set temperature has been reached.
The stove should be used as an auxiliary and temporary heating system, to heat
rooms, gazebos, garages, labs and any other room that is above ground and
suitably ventilated. It must not be used in bathrooms or dormitories, in
boats, recreational vehicles and in rooms located on a high floor of a
building. Any other use, or the extended use of the appliance, is to be
considered improper use and the user will be held responsible for any possible
consequent risk.
2.3 Safety devices
The product has been designed to prevent hazards thanks to the presence of the
following safety devices:
Thermocouple
The pilot flame heats up a thermocouple which, in turns, keeps the valve of
the appliance open (not the valve of the cylinder). If the pilot flame goes
out, the gas flow from the valve to the appliance automatically stops within
approximately one minute.
ODS
A pilot flame with an ODS system goes out and stops the gas supply before the
level of CO2 exceeds the 1.5% limit (in the room where the room is used).
To prevent activation of the ODS system, the gas stove must be used only and
exclusively in well-ventilated rooms.
Ensure that the room is suitably ventilated and, if the ODS system has
triggered, ventilate the room. If you need to intervene too often, this means
that the room is too small or that ventilation is not sufficient.
Minimum recommended volumes
With ON OFF thermostat :
Automatically variable Power 4.2 kW
Heatable volumes:
Sitting room
Other rooms| 84 m3
42 m3
---|---
Heatable volumes with the useful power of the stove (maximum efficiency power)
Key:
Um: indicates the average transmittance value of all the dispersion structures
present in the room to be heated (W/m2.K) Important remarks: the values shown
in the table refer to “standard” domestic rooms with a temperature of 20 °C ±
2°C The rooms heated directly by the appliance should not feature partition
walls; in other words, they should be free from inner barriers.
The table is for information purposes only. Considering that there are many
parameters involved, we recommend contacting a thermos-technical engineer in
order to obtain a final evaluation.
Piezoelectric ignition
This is the safest ignition method as it does not require a flame to manually
ignite the appliance.
Safety grid
The grid present on this device prevents the risk of fire or burns: for this
reason, it shopermanently removed. IT IS NOT A FULL GUARD FOR CHILDREN OR
DISABLED PEOPLE.
2.4 Specifications
Nominal heat input: 4,2 kW
Heat settings: Maximum power for ON-OFF appliances
Igniter: electronic ignition
Nominal output pressure: 28 mbar
Gas type: Butane
Gas category: I3B
Size of cylinders (net weight): 15 kg
Country of destination: GB – IE
BLUE BELLE CHIC/TO
Product dimensions | (L x D x H): 38.5 x 43.5 x 77 cm |
---|---|
Weight of the appliance | 13 kg |
2.5 Power and consumption
The stove operates with 15 kg cylinders containing ecological LPG
butane/propane available on the market.
Depending on the room temperature and on the desired power, the consumption of
the gas stove is as follows: (The values are only indicative).
Automatically variable
305 g / h (at 4200 W) maximum
2.6 Safety features
The improper use of this appliance may cause serious damages to the health of
people and to property.
Please, read the instructions carefully.
Familiarise with the appliance before using it.
Respect the general safety regulations on accident prevention. The information
provided by this manual, as well as the laws in force on general safety and
accident prevention, must be complied with.
Thirds should only be allowed to use the appliance once they have been given
the appropriate instructions. The appliance is not intended to be used by
persons (children included) with reduced physical, sensory or mental
abilities, or without the necessary experience and knowledge, unless they have
been instructed on the use of the appliance or are supervised by someone who
is responsible for their safety. Children should not be permitted to use and
play with the appliance.
If the appliance is on and powered, it should not be left unattended.
Pay attention and take care when using the appliance.
Do not use the product if you are distracted or under the influence of drugs,
alcohol or medication. When operating the appliance, even the slightest
distraction may cause serious accidents and injuries.
2.7 General safety warnings for installation and use
The stove must be installed on a solid and even surface.
Do not use the appliance in bedrooms, bathrooms, basements or on high floors.
Do not use the appliance as a permanent or continuous heating system. Do not
use the appliance in bathrooms, dormitories, recreational vehicles, such as
caravans, motorhomes, boats and on high floors of buildings.
Do not use the appliance in basements or below ground level.
Do not use the appliance in dangerous areas.
Do not use the appliance in rooms where the presence of flammable liquids, gas
and airborne dust may pose a risk of explosion or fire.
Do not use the appliance in rooms that are smaller than those indicated in the
table that illustrates the minimum recommended volumes
Do not touch the hot parts of the appliance.
The appliance should be positioned at no less than 1 m from other heat
sources.
Do not install the appliance in a room that already contains a gas cylinder
(even if it is not in use)
To lift or move the appliance from its intended position, use the dedicated
handles.
Never pull the gas hose to move the appliance.
Do not move the appliance while it is operating.
Do not move the stove while it is hot.
Check for any damage: always check that the appliance is in good working order
before using it.
Respect the current local, regional and national regulations on gas.
The appliance must be used in a dry, clean and ventilated room.
The appliance should be used only in adequately ventilated rooms. To ensure
ideal air ventilation, provide two openings of at least 25 cm
per kW/h of heat (minimum opening 105 cm2 – 1/2 in high position and 1/2 in
low position in the room)
The ventilation openings must be free as their purpose is to guarantee
adequate ventilation, which ensures correct combustion.
The front guard guarantees protection from burns that may be caused by
accidental contact with the flame.
IT DOES NOT CONSTITUTE FULL PROTECTION FOR SMALL CHILDREN AND DISABLED PEOPLE.
Do not remove any part that make up the guard.
Do not cover the stove using cloths, clothes or wet laundry that needs drying.
Do not cover the stove as this would cause overheating. It is dangerous and
therefore forbidden to position objects on the stove, as this would cause
overheating.
Do not position the stove near armchairs or curtains (remember to take into
consideration that curtains move) or other flammable material.
Any object must be positioned at a minimum of:
20 cm from the rear side of the stove
50 cm from the sides of the stove
100 cm from the front side of the stove
The cylinder compartment can house cylinders of up to 15 kg.
The stove should not be subjected to air current that exceeds 1.2 m/s.
ATTENTION: Do not point fans directly toward the stove. Avoid air
currents that may change the flame of the burner.
When connecting the cylinder for the first time, and any time the cylinder
needs to be replaced, ensure that the room is well ventilated and that there
are no naked flames. Do not smoke while carrying out these operations.
Do not remove or tamper with the regulator or with any other component of the
stove.
Protect the stove from the weather.
Do not clean the stove with abrasive products.
Do not put sharp tips and/or metal objects inside the appliance.
Avoid improper use. The appliance should be used only and exclusively for the
intended purpose.
The appliance should be regularly checked for wear and tear signs and for
damages by qualified, authorized and trained technicians. Special care should
be taken for hoses and connections. Use only and exclusively original spare
parts. For your safety, only use the spare parts expressly indicated in the
user manual.
Repair works must be carried out by a qualified technician. Have a qualified
technician inspect the stove at least once a year.
The presence of excessive dirt caused by carpets, animal litter, pet hair,
etc. may require more frequent maintenance operations.
Do not use the stove if it has been immersed in water, even partially. Contact
a qualified technician to replace any part of the control system and any part
of the gas system that were immersed in water.
When igniting the stove after an extended period of inactivity, ensure that
there are no foreign bodies inside it, such as dirt, insects, spider webs, and
have the stove checked by a qualified technician.
WARNING: do not use unapproved accessories.
All the components that were removed to carry out maintenance operations must
be put back in place before igniting the appliance.
This heating system should be used only and exclusively as indicated in this
manual. Any other use may
cause fires, personal injuries and even death.
To turn off the appliance and put it out of service, close the gas valve on
the cylinder and remove the cylinder itself.
2.8 Conduct in case of gas leaks
If you smell gas, proceed as follows!
If you smell gas, do not ignite the device and close the cylinder valve by
turning it clockwise.
Do not touch any switch and do not use the phone.
Open doors and windows to ventilate the room.
Extinguish any flame or other potential ignition sources.
No naked flames and no smoking.
Carry out the test operations indicated in 3.4. Never carry out the test in
the presence of naked flames.
If there are no leaks, ignite the stove taking special care and in compliance
with the instructions provided inthe user manual.
If you still smell gas, try to replace the cylinder as the gas may contain an
excessive amount of aromacompound.
If the problem is not solved, contact the distributor or a specialized
technician.
Do not use the appliance until it hasn’t been inspected by a qualified
technician.
Never attempt to make any repair work yourself.
Failure to observe this warning may result in injuries or damage to property.
Preparing the appliance for operation
3.1 Opening the packaging
Upon delivery, check that the appliance is complete and in perfect conditions.
If there are missing components or faults, do not use the product and contact
the seller immediately.
3.2 Keeping the original
packaging Keep the original packaging for the whole life of the appliance. Use
the packaging to store and transport the appliance. Dispose of the packaging
at the end of the life-cycle of the appliance. For further information on
correct disposal, please refer to chap. 8.
3.3 Connecting the stove to the gas bottle
**** Never position the cylinder upside-down! When connecting the cylinder
for the first time, and any time the cylinder needs to be replaced, ensure
that the room is well ventilated and that there are no naked flames. Do not
smoke while carrying out these operations.
If the cylinder has been transported, store it in upright position for at
least 1 hour before using it.
Ensure that the gas seal on the cylinder is intact and in perfect conditions.
Check that the connections (the regulator ring and the thread on the cylinder
valve) are clean and undamaged. Connect the cylinder outside the appliance, as
illustrated here below:
Read thoroughly before use.
The following operations are required for the connection:
– Only use this regulator on a Butane gas cylinder with a 21mm (G53) cylinder
valve.
– The LP nozzle outlet connection shall only be connected to 8mm Tubing to
BS3212 Type 1, 8mm Hose to BS3212 Type 2, 8mm Tubing to BS EN 16436 Class 1,
8mm Hose to BS EN 16436 Classes 2 or 3.
– The gas cylinder must always be in vertical position and the regulator must
never be disconnected while the appliance is turned on.
– Make sure that the hoses are kept clear of hot surfaces and inspect before
use. Replace any hose that shows signs of wear, cracking or other damage.
– In case of gas escape or malfunction, close the gas supply and contact your
dealer.
– Do not use a flame to test for gas leakage: Use a soapy water solution.
– If a regulator shows signs of wear, damage or deterioration it should be
replaced.
– In normal conditions of use, in order to ensure the correct operation of the
of the installation, it is recommended that this regulator is changed within
10 years of the date of manufacture.
Fitting the tubing or hose (fig.1) (Replacement of the hose)
Use only tubing or hose certified to BS3212 or BS EN 16436 as LPG attacks and erodes natural rubber and plastics. Maximum length 40 cm. Connect the end of the hose (3) to the regulator outlet, if necessary with the aid of soapy water. Fasten the hose using hose clips (4). To prevent damaging the hose do not over-tighten the hose clips.
Connecting to the gas cylinder
Turn the orange cap on the cylinder valve so that the arrow is pointing to
thgap in the shroud.
Remove the orange safety cap by pulling the lanyard out, then up.
Do not use tools.
Check the black sealing washer is fitted inside the top of the cylinder valve.
Make sure that:
a) The regulator is switched to the ‘off’ or disconnect position(the regulator
is OFF when a green rectangle is visible on the handle. See fig. 2) b) The
hose to the appliance is correctly fitted.
c) The valve is clean and free from debris.
Put the regulator on top of the cylinder valve. Place your hand on fig. 3. top
of the regulator and push down firmly and vertically until you hear a click.
NOTE: The regulator can only be fitted to the cylinder valve when the
control knob is in the “OFF” position.
Turning the regulator on
After fitting the regulator correctly onto the valve, turn on by rotating the
control knob anticlockwise half a turn until it stops.
In the ON position a red flame and the marking “ON” is visible. Please, see
fig. 4.
Caution: If you are unable to turn the regulator to the “ON” position,
your regulator is not correctly connected to the valve. Do not force the
handle,repeat the operations described above.
Turning the regulator off
Turn the control knob clockwise half a turn until it stops. Please, see fig.
2.
In the “OFF” position the valve is closed, but the regulator will remain
attached to the cylinder valve.
ALWAYS turn the control knob to the “OFF” position after use. If the appliance
is not going to be used agasoon, disconnect the regulator from the cylinder.
Disconnecting the regulator
Make sure the regulator control knob is turned to the ‘OFF’ position with the
green rectangle visible and that the appliance flame is extinguished.
Remove the regulator by pressing horizontally on the control knob (5) and then
pulling upwards (fig. 5).
Always replace the orange safety cap onto the cylinder valve, when not in use.
Never try to attach or remove the regulator from the cylinder valve unless the
regulator handle is in the OFF position. It is not possible to press the
control knob to release the regulator if it is not in the correct horizontal
position with the marking “OFF” visible.
Do not attempt to disconnect the regulator from the cylinder if the appliance
flame does not go out when theregulator is turned ‘OFF’. Leave appliance
alight and call your local dealer.
The following operations are required for the connection:
– This regulator is a domestic regulator used to supply gas to utilities at
specific pressure and flow, as indicated on the label (1).
– The regulator must be fitted directly to a cylinder featuring a O35 mm
(G.56) quick connection valve. Make sure that the inlet and the outlet of the
regulator are correct and suitable for the cylinder valve and the application.
– The gas cylinder must always be kept in vertical position. Do not move the
cylinder during the operation. When the device is used outdoors, it shall be
positioned or protected against direct penetration by any tracking water.
– Regulator versions featuring a release valve (the marking ”PRV” is visible
on the label (1) are generally not type approved for use in closed premises
(see local laws on the subject).
– Regulator operating temperature range is 0/+50°C for Butane and -20/+50 °C
for Propane and LPG.
– Never look for gas leaks with a live flame. Use instead a solution of water
and soap.
– In the event of any faults being found, close the regulator knob and
immediately contact your gas supplier.
– Avoid that the hole on the cover (VENT) is obstructed or stopped (6).
– This regulator cannot be used on caravans and motor homes.
– For a permanent use outside the house, install the regulator in a position
protected from the weather, paying great attention to the position of the vent
hole (6).
Until the time of installation, the product must be stored in a clean, dry
location protected from weather, atmospheric agents and direct sunlight. It
must not be knocked or dented in any way.
Before installation, inspect the product for damage and dirt.
Damaged products must not be installed.
Fitting the rubber hose (fig.1) (Replacement of the hose)
Connect the end of the hose (3) to the regulator outlet, if necessary, with
the aid of soapy water. Fasten the hose using clamps (4). Do not over-tighten
to prevent damaging the hose (in some countries, the hose clamps and the hose
are of standards dimensions).
Assembling on the gas cylinder.
Make sure that:
– All taps of the gas consuming appliance are closed.
– The connecting pipe is correctly fitted to the consuming appliance.
– Make sure the handle is in the “closed” position (the regulator is OFF when
a green rectangle is visible on the handle. See fig. 2)
– Remove the plastic protective plug from the automatic valve.
– Pull the ring (5) upwards as shown in figure 3 and fit the regulator onto
the valve. Afterwards give the ring (5) a strong push downwards as shown in
figure 4. A “click” should be heard, meaning the regulator has been correctly
fitted.
Operation
OPEN (ON): After correctly fitting the regulator onto the valve, the gas flow can be opened by turning the knob a half turn counterclockwise until the stop, until you reach the opposite horizontal position. In this position a red flame with the “ON” is visible as shown in figure 5. In this position the valve is opened and the gas flow is allowed. CLOSED (OFF): The gas flow can be stopped by turning the knob a half turn clockwise until the stop, until you reach the opposite horizontal position “OFF”. In this position the valve is closed.
Replacement of a cylinder
Make sure that:
– All the taps of the user appliance are closed.
– The opening knob of the regulator is in the closed position (by turning it a
half turn until the stop the red flame is not visible, “OFF”). Afterwards,
remove the regulator by pulling the ring (5) as shown in figure 6.
NOTE: It is not possible to pull the ring until the knob is in the
horizontal position and the marking “OFF” is not visible. This is an important
security feature. The user must not try to pull the regulator ring if the knob
is not in the “OFF” position. Please contact your gas supplier if you have any
problem.
Gas leaks
All gas leaks, however small, are dangerous and must be eliminated. Escaping
gas can normally be traced by smell or sound but liquid detergent should be
brushed over the area to confirm the location of the leak. NEVER look for a
leak with a naked flame.
On cylinders, if a leak is suspected, turn off gas supply immediately, and
extinguish any standing pilot lights or naked flames. Ventilate the room if
possible. If the cylinder is indoors, move the cylinder outdoors to a safe
place, and call your dealer for advice.
Excess flow valve (EFV)
The regulator can be equipped with a safety device “excess flow valve”
designed to stop gas escaping in case of accidental detachment or breakage of
the rubber hose used to supply gas to the user appliance.
The marking “EFV” on the label (1) shows the presence of this device on the
regulator.
The flow limiting device should operate as follows:
-
In the event of the hose moving from its correct position:
– Close the regulator knob,
– Fit the hose correctly back on the regulator hose connection.
– Open the regulator knob,
– Wait at least 20 seconds before opening the regulator again. -
In case of the flow of gas being higher than the capacity of the regulator, contact your gas supplier.
Maximum residential flow: 60 g/h.
NOTE: The excess flow valve may close if the gas cylinder is moved during use. To ensure correct operation of the flow limiting device during gas supply, the appliances hose length should be 1.5m at maximum. In normal conditions of use, in order to ensure the correct operation of the of the installation, it is recommended that this regulator is changed within 10 years of the date of manufacture
IMPORTANT: Never leave the regulator connected to the cylinder valve when the rubber hose is not correctly fitted in its housing as the flow limiting device has not been designed to guarantee the gas supply shut off function. The product must never be tampered with or dismantled; any such procedures lead to forfeiture of warranty cover on the product and the manufacture declines all consequent responsibility.
Emergency advice
If you suspect a leak, turn off the gas, open all the doors and windows and
ensure there is no sourceignition nearby i.e., extinguish any cigarettes and
switch off your mobile phone.
Examine all hoses and connections. If the leak is not located, turn on the gas
supply and brush overconnections with liquid detection fluid or a soapy water
solution – it will bubble where there is a leak.NEVER USE A NAKED FLAME to
search for a leak. LPG has an odorant added to help with the detof leaks.
In the Event of Fire, immediately raise the alarm and call the Fire Brigade
advising them of the presLPG.
Turn off the regulator on the cylinder by turning the control knob clockwise.
Keep cylinders cool by water spray if possible.
Ring local Emergency Service number.
3.4 Checking the regulator for leaks
Never use a naked flame to check for leaks. USE ONLY AND EXCLUSIVELY FOAM
SOLUTIONS!
After installation, and any time it is necessary, check the connection of the regulator as follows:
- Connect the regulator to the cylinder.
- Spray the cylinder connection with combustible gas leak detector. The formation of bubbles indicates a leak.
- If the problem is the connection between the regulator and the cylinder the connection needs to be checked.
- Repeat steps 1 and 2. Check that the problem has been solved.
If it is impossible to fix the leak, remove the regulator and check that the connection is not uneven or dor that the seal is not damaged; the connection needs to be tested by a qualified technician. If the foamy solution detects a further leak, close the regulator handle, replace the cylinder and try againShould there still be a leak after replacing the cylinder and carrying out the check, do not use the stove contact your seller (see chapter 6). Repair works or faulty component replacement must be carried ouqualified technicians who must use original components.
ATTENTION:
Ensure that the gas hose has enough space and is not bent. The gas hose should not be stretched or twisted.
Instructions for use
4.1 Commissioning and operation
After installing the cylinder and carrying out the tightness test, the gas
stove can be ignited. Please follow the instructions given here below:
Instructions for using the stove with ON OFF thermostat
-
Install the stove in the desired position, in compliance with the instructions and warnings given in paragraph 2.7 “General warnings on installation and use”.
-
Open the cylinder valve by rotating it anti-clockwise.
-
Turn the knob (fig. 4) clockwise until it stops: this position corresponds to the START position Press the knob all the way down and keep it pressed for approximately 45 seconds. After that, while keeping the knob pressed down, press the piezo push-button until the pilot flames comes on.
-
Once the pilot flame has come on, keep the knob pressed for 20/30 seconds and then release the knob.
-
If the pilot flame extinguishes, repeat steps 3 and 4 until the pilot flame comes on correctly (Fig. 8).
-
At this point, to start the burner, slowly turn the thermostatic adjustment knob anti-clockwise until it stops, corresponding to the number 7 on the knob.
-
When the room has reached the desired temperature, slowly rotate the knob clockwise until the burner stops: the pilot flame will stay always on and at this point the stove ignites and shuts down autonomously, maintaining the desired temperature.
ATTENTION: the numbers on the knob are only a reference for the position.
N.B.: When the stove is ignited for the first time, and any time the cylinder
needs replacing, the pilot light will need a little more time to come on. This
is due to the air present in the gas circuit.
N.B.: When the stove is ignited for the first time, it generates a little
smoke. This will not happen again.
4.2 Shutting off
Turn gas off at the regulator in accordance with the regulator instructions.
In the “OFF” position the valve is closed, but the regulator will remain
attached to the cylinder valve. Ensure that it is well closed. Only after the
regulator handle has been correctly closed can the applianceswitched off
completely.
4.3 Replacing the cylinder
When replacing the cylinder, ensure that the room is suitably ventilated.
Ensure that the gas valve is safely closed.
Do not use any tool to remove the pressure regulator: just disconnect the
regulator in accordance with the regulator instructions.
Attention! Install the new cylinder by following the instructions given
in this manual.
4.4 Storage (how to store the stove)
When the stove is not in use, it must be stored without the cylinder. It must
be put in its original packaging, covered using a nylon bag and stored in a
dry place so that no dust, insects or insects nest can enter the components of
the stove.
4.5 Packaging for private transport
To prevent damaging the appliance during transport, the gas stove must be
packed in its original packaging and the cylinder must be removed. Fasten the
gas hose and the pressure regulator.
Maintenance
5.1 Cleaning and maintenance
Ensure that the gas valve is completely closed.
Do not carry out any maintenance or cleaning operations until the stove has
cooled down completely.
The stove must be cleaned using only and exclusively a dry cloth. Never use
pointed or abrasive tools and always wait until the stove has cooled down.
Never clean the stove when it is on and hot Repairs may only be performed by
qualified and certified installers, using original components.
Annually check the status using the appliance and, should you have any doubt,
have it checked by a qualified technician.
Check the state of wear of the flexible hose and replace it, if necessary.
Check the condition of the gas hose periodically for damage. A leak test
should be performed before using the appliance if it hasn’t been used for a
long time (see section 3.4).
If any damage is found on the gas hose, have it replaced by a qualified
technician together with the pressure regulator.
If necessary, contact a servicing centre.
Cleaning and maintenance operations that require removing any component must
be carried out by a qualified technician.
Any maintenance work carried out during the first 24 months by unauthorised
technician, will render the guarantee null and void.
Note: Replace the approved pressure regulator EN 16129 and the approved gas hose EN 16436-1 after 10 years from the date of manufacture. The gas tube should have a length of 40 cm. The date of manufacture is printed on the pressure regulator and on the gas hose. This operation must be performed by a qualified technician using only original spare parts.
5.2 Faults and repair works Fault Possible Causes Solutions
Yellow pilot flame| The gas cylinder is running low. The nozzle is dirty or
clogged.| Replace the cylinder. Clean with compressed air. D o not use tools.
---|---|---
The flame in the burner is yellow| The gas cylinder is running low. Dirty gas.
The room is very dusty.
When walking near the stove, dust is sprayed around.| Replace the cylinder.The
flame slowly stabilizes on its own.
The pilot flame does not come on.| The cylinder is empty. See instructions in
4.1 The nozzle is empty or clogged by dust, insects or insect nests. No spark|
Replace the cylinder. Follow the instructions in 4.1Clean with compressed air.
Do not use tools. Contact a specialized technician.
If the appliance is fitted with battery-power ignition, replace the battery.
Check the connection of the piezo’s electrical wire.
Use a match and ignite through the dedicated peephole.
The stove shuts down
during operation| ODS tripped. The gas cylinder is empty.| Ventilate the room,
wait for a few minutes and ignite the stove again. If the problem persists, it
means that the room is too small or not adequately ventilated. Replace the
cylinder.
Leak test failed| See instructions in 3.4 The gas circuit is damaged.| Follow
the instructions in 3.4 Contact your gas dealer.
The regulator does not
screw in| The thread on the cylinder gas valve is damaged.| Replace the gas
cylinder. If the problem is not solved, contact the seller.
The main burners do not ignite| The gas cylinder is empty The burner unit is
clogged| Replace the cylinder. Contact a specialized technician.
Warranty
TMC guarantees its products for a period of 2 years, provided that the following conditions are met:
- the guarantee period starts on the day the stove is delivered with a purchasing document such as an invoice, a transport document or a payment receipt.
- All the parts that are proven to be defective due to faulty manufacture will be replaced during the guarantee period, and no charge will be applied for materials and labour.
- Warranty inspections are at the sole discretion of TMC.
- The following items are not included in the warranty: the regulator, the flexible hose and all such components that are proven to be faulty due to unsuitable use, storage or maintenance operations.
- Any transport expenses for repair works during the warranty period will be charged to the purchaser.
- The warranty shall be invalidated in case of: damages during transport or damages due to lack of care, unintended use, incorrect installation or failure to comply with the instructions given in this manual.
- The manufacturer’s warranty shall be invalidated in case of works carried out by people who were not expressly authorised to operate on the appliance.
- Any repair work and/or replacement carried out during the warranty period do not extend the warranty itself.
- Cleaning of the components (e.g. burner, pilot flame block, nozzles) is excluded from the warranty.
- The manufacturer is not liable for damage any to persons or property due to installation that is not compliant with the instructions or to improper use of the appliance.
Spare parts
When placing an order for spare parts, please provide the description and code
of the spare part you require. (see exploded view drawing)
BLUE BELLE CHIC/TO
1 | CYLINDER COVER |
---|---|
2 | ELECTRONIC PIEZO |
3 | BATTERY (AAA type) |
4 | VALVE SUPPORT |
5 | VALVE |
6 | COVER* |
7 | UPRIGHT HANDLE |
8 | UPRIGHT* |
9 | REAR PROTECTION PLATE |
10 | PLATE |
11 | REFLECTOR |
12 | FRONT PANEL |
13 | HANDLE |
14 | PRINTED BOTTOM PLATE |
15 | CASTORS |
16 | BURNER TUBE |
17 | ANALYZER PIPE |
18 | BURNER UNIT |
19 | ANALYZER |
* Specify the colour
TMC reserves the right to make technical changes.
7.1 Changing the battery
When the battery that powers the electronic ignition is dead, it must be
replaced in compliance with the instructions and respecting the polarity.
The electronic ignition block contains an AAA type battery. To replace the
battery, turn the top of the piezoelectric igniter (see Fig. 5) anti-clockwise
and pull the unit up.
2. Remove the old battery and replace it with a new one (1 AAA type battery,
1.5 V), respecting the polarity.
Disposal
**** To protect the environment, the packaging and any packaging material are
made using 100% recyclable material that can be treated as urban waste.
Once the product has reached the end of its life cycle, it cannot be disposed
of as urban waste. Contact the local authorities to find out about the options
for waste disposal in your area.
EU DECLARATION OF CONFORMITY
LPG CABINET HEATER BLUE BELLE CHIC/TO
Type: 22D
(Domestic flueless heaters – UNI EN 449)
The Company:
TMC S.r.l.
Traversa Viale del Lavoro, 1
I – 37013 CAPRINO VERONESE (VR)hereby declares under its own responsibility
that the following appliances:
BLUE BELLE CHIC/TO
have been developed and produced in compliance with the EU regulation on gas
products 2016/426, thedirective 2009/125/EU, the regulations 2015/1186 / EU,
2015/1188 / EU and in compliance with the harmonized standard EN 449: 2002 +
A1: 2007 and are subjected to EC type-approval test.
Notified body CE-0085 has issued the certificate: CE0085BM0301
DVGW CERT GmbH Zertifizierungsstelle
Josef-Wirmer-Str. 1-3
53123 BONN – DE
Validity start of the certificate: 04/21/2018
Expiration of validity of the certificate: 02/13/2028
Supervisory body CE-0085 (DVGW):
Signed for and on behalf of:
Bruno Cristini
Sole Director
UK DECLARATION OF CONFORMITY
We: TMC srl
Address: Traversa Viale del Lavoro, 1- 37013 Caprino Veronese – Verona Italy
Declare that Indipendent space heater (LPG)
BLUE BELLE CHIC/TO
Satisfies the essential requirements of the Regulation 2016/426 on gas
appliances as brought into UK law and amended and is manufactured in
accordance with the UK designated standards:
Standards Number(s):
BS EN 449:2002 +A1 2007
BS EN 461:1999 inc A1 2004
2009/125/EU
2015/1188/EU
2015/1188/EU
BSI has performed the following conformity assessment procedure(s) specified
in the Regulation 2016/426 on gas appliances as brought into UK law and
amended:
- Annex III Module B (Type Examination) and issued the Certificates below: UKCA Module B certificate: UKCA 753788
Approved Body: BSI Assurance UK Limited (Approved Body No. 0086)
Address: Kitemark Court, Davy Avenue, Knowlhill Milton Keynes MK5 8PP UK.
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
In the case of fittings, instructions on how the fitting should be
incorporated into an appliance orassembled to constitute an appliance in order
to assist compliance with the essential requiremenapplicable to finished
appliances.
Bruno Cristini
Sole Director
Caprino Veronese, 21/09/2021
Information requirements for gaseous/liquid fuel local space heaters
Model identifier(s): BLUE BELLE CHIC/TO
Indirect heating functionality: No
Direct heat output: …(kW) 4.2 kW
Indirect heat imput: …(kW) 0 kW
Product fiche
a.Manufacturer
b.Model:
c) Energy efficiency class.
A
(A++ <> G)
d)Direct power heat imput.
e)Indirect power heat imput.
g) useful energy efficiency at nominal heat output .