Event Lighting PAR19X12L 19x 12W LED RGBWAU Parcan with IR Remote User Manual
- June 13, 2024
- EVENT LIGHTING
Table of Contents
- Event Lighting PAR19X12L 19x 12W LED RGBWAU Parcan with IR Remote
- Product Information
- Product Usage Instructions
- Safety Instructions
- Product Installation
- Control Board Operation
- DMX Chart
- IR Remote
- Technical Specifications
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Event Lighting PAR19X12L 19x 12W LED RGBWAU Parcan with IR Remote
Product Information
The PAR19X12L is a 19x 12W LED RGBWAU Parcan with an IR Remote. It is a versatile lighting fixture used for events and performances. The product dimensions and lux chart can be found on the Event Lighting website. The control board allows for various settings and modes to customize the lighting effects. The fixture should be handled with caution and allowed to cool for at least 15 minutes before touching. Safety precautions should be followed, such as keeping flammable materials away and keeping batteries out of reach of children.
Product Usage Instructions
- Ensure the fixture is mounted securely using the correct mounting bracket. Use a safety chain when mounting overhead.
- To operate the control board, follow the menu map provided in the user manual. Use the arrow keys to navigate and the Enter button to select.
- To set the DMX address or channel mode, use the arrow keys to navigate to the respective option and use the minus or plus buttons to adjust the value.
- To set program speed, select built-in programs, or activate sound active mode, follow the same process as in step 3.
- To select static color mode, refer to the static color mode chart provided in the user manual. Use the arrow keys to navigate and the minus or plus buttons to adjust the value.
- To set strobe speed, color intensity (red, green, blue, white, amber, UV), dimmer speed, or toggle LED display on/off, follow the same process as in step 3.
- To view current temperature or software version, long press the Enter button.
- To restore settings to factory default, navigate to the respective option and select it.
- The IR remote can be used to control the PAR19X12L. Refer to the IR remote section in the user manual for detailed instructions.
For any clarification or further information, please consult Event Lighting.
For your safety, please read this user manual carefully before use.
Event Lighting reserves the right to revise the manual at any time.
Information and specifications within this manual are subject to change
without notice. Event Lighting assumes no liability or responsibility for any
errors or omissions. Please consult Event Lighting for any clarification or
information regarding this item.
Safety Instructions
Warning
- Do not open this device, there are no user serviceable parts inside. Risk of electric shock.
- Do not look directly at the light source from close range.
- Avoid contact with the unit during operation, as the housing may become hot. Allow the fixture to cool for at least 15 minutes after turning off before touching.
- Install this device in a location with adequate ventilation, at least 50cm from adjacent surfaces.
- Do not operate this device, or connect this device to power, within 50cm of any flammable material.
- Use a safety chain when mounting this device overhead.
- Do not operate this device outdoors where excessive dust, heat, water, or humidity may affect it.
- Do not operate this device if the housing, lenses, or cables appear damaged.
- Do not connect this device to a dimmer or rheostat.
- Do not operate this device at temperatures higher than 40°C (104°F).
- Only connect this device to a grounded and protected circuit.
- Only use the hanging bracket to carry this device.
- Stop using this device immediately if a serious operating problem becomes apparent.
Coin/Button Cell Battery Safety Information
This product includes an IR remote that contains a coin/button cell battery. If the battery is swallowed, it can cause severe internal burns and, in extreme cases, can lead to death. Keep batteries away from children.
Product Installation
PAR19X12L can be mounted in many orientations, provided each individual device is secured by the use of the correct mounting bracket. Use a safety chain when mounting PAR19X12L overhead.
Dimensions
Lux Chart
Control Board Operation
Menu Map
Static Colour Mode
Value | Function |
---|---|
C1 | Red |
C2 | Green |
C3 | Red+Green |
C4 | Blue |
C5 | Blue+Red+UV |
C6 | Green+Blue |
C7 | Red +Green+Blue+Amber+UV |
C8 | White |
C9 | Red+White |
C10 | Green+White |
C11 | Red+Amber |
C12 | Blue+White+UV |
C13 | Red + Blue+White+UV |
C14 | Red + Blue+White |
C15 | Red+Green+Blue+White+Amber+UV |
DMX Chart
6 Channel Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red: 0% ~ 100% |
2 | 000-255 | Green: 0% ~ 100% |
3 | 000-255 | Blue: 0% ~ 100% |
4 | 000-255 | White: 0% ~ 100% |
5 | 000-255 | Amber: 0% ~ 100% |
6 | 000-255 | UV: 0% ~ 100% |
11 Channel Mode
Channel | Value | Function | Note |
---|---|---|---|
1 | 000-255 | Master Dimmer 0% ~ 100% | |
2 | 000-255 | Red: 0% ~ 100% | |
3 | 000-255 | Green: 0% ~ 100% | |
4 | 000-255 | Blue: 0% ~ 100% | |
5 | 000-255 | White: 0% ~ 100% | |
6 | 000-255 | Amber: 0% ~ 100% | |
7 | 000-255 | UV: 0% ~ 100% | |
8 | 000-012 | Strobe OFF | |
013-255 | Strobe (slow-fast) | ||
9 | 000-009 | No Function | |
010-019 | Program 1 | ||
020-029 | Program 2 | ||
030-039 | Program 3 | ||
040-049 | Program 4 | ||
050-059 | Program 5 | ||
060-069 | Program 6 | ||
070-079 | Program 7 | ||
080-089 | Program 8 | ||
090-099 | Program 9 | ||
100-109 | Program 10 | ||
110-119 | Program 11 | ||
120-129 | Program 12 | ||
130-139 | Program 13 | ||
140-255 | Sound active mode | ||
10 | 000-255 | Speed of auto programs (slow ~ fast) | Ch9 must be set between |
10-139
11| 000-255| Colour fade time (jump ~ fade)| Mode must be set to “nod0”
IR Remote
- In order to use the IR Remote, PAR19X12L must be in DMX mode without an active DMX connection. If a DMX signal is received, PAR19X12L will prioritise the DMX signal and ignore the IR Remote.
- Use On/Off to turn PAR19X12L on or off. The current IR settings will be saved automatically when PAR19X12L is powered off and reloaded when it is turned on again. To reset to the factory default Blackout mode, long press Off.
- Press R/G/B/W/A/U to light up the LEDs in red, green, blue, white, amber or UV respectively. Press a number 0-9 in the orange shaded area to select a pre-set colour.
- Press + to increase the intensity of the selected colour and – to decrease the intensity of the selected colour.
- Press Auto/Sound/Strobe to switch on or off Auto mode, Sound Active mode and Strobe mode, respectively.
- Press Blackout to clear all the remote settings and blackout PAR19X12L.
Technical Specifications
Photometric
- Light Source: 19x 12W RGBWAU 6-in-1 LEDs
- Beam Angle: 40°
- PWM: 20,000 Hz
- LED Lifespan : 50,000 hours
Effects
- Dimming: 0~100%
- Strobe: 1 – 20 Hz
Power
- Input Voltage: 100~240V AC, 50/60Hz
- Power Consumption: 190W
- Connection: powerCON in/out
Control
- Protocol: DMX512
- DMX channels : 6/11
- Interface: 3-pin DMX in/out
- Built-in Programming : Yes
- Display: 4-button and 4-digit LED control panel
- Operation Modes: DMX, manual, auto, sound active, IR remote, master/slave
Housing
- Materials: Die cast aluminium, matte black finish
- Cooling: Fanless Cooling
- Net weight: 2.8 kg
- Overall Size : 275x270x84 mm
Warranty
Please refer to your local dealer or contact Event Lighting.