PROMINENCE HOME 51866 52 Inch Blade Indoor Ceiling Fan
Product Information
52 CEILING FAN
The 52 Ceiling Fan is a high-quality fan designed for use in damp locations. It comes with various components and hardware required for installation. The fan features a motor assembly, switch housing, blade balancing kit, and three blades for optimal airflow. It is equipped with a downrod for mounting and can also be installed on angled ceilings up to 16 degrees. The fan is rated for safe and efficient operation.
Product Usage Instructions
- Before starting the installation process, ensure that the electrical power is turned off at the main fuse or circuit breaker to prevent any accidents or injuries.
- Begin by loosening all four mounting bracket screws and removing the canopy from the mounting bracket.
- Install the mounting bracket to the outlet box using the screws and washers provided with the outlet box. Make sure to mount it to an outlet box marked acceptable for fan support.
- Remove the downrod clip and downrod pin from the downrod. Then, loosen the two set screws at the top of the yoke without completely removing them.
- Feed the wires and braided cable coming from the yoke through the yoke cover, canopy, and downrod.
- Slide the downrod into the yoke of the motor assembly, aligning the holes. Re-install the downrod pin and tighten the set screws.
- Attach the blades to the blade arms using the provided blade screws and washers.
- Secure the blade arms to the motor assembly using the motor screws saved from step 2.
- Attach the switch housing plate to the motor assembly using the provided switch housing screws.
- Install the fitter plate on the switch housing plate using the fitter plate screws.
- Attach the desired blade balancing kit to the blades as needed for proper balance.
- Finally, refer to the owner’s manual for instructions on wiring and operating the fan.
Please follow these instructions carefully to ensure safe and successful installation of your 52 Ceiling Fan. If you require any assistance or have any questions, please contact our Service Department at 1-877-706-3267, Monday – Friday, 8 a.m. – 5 p.m. Central.
To obtain service, please contact the Service Department: 1-877-706-3267, 8 a.m. – 5 p.m. Central, Monday – Friday.
PACKAGE CONTENTS
Unpack your fan and check the contents. You should have the following items:
- Canopy
- Canopy Cover
- Mounting Bracket Screw (x4)
- Mounting Bracket
- Downrod
- Downrod Clip
- Downrod Pin
- Yoke Cover
- Set Screw (x2)
- Motor Screw (x6)
- Motor Assembly
- Fitter Plate
- Fitter Plate Screw (x3)
- Switch Housing Plate
- Switch Housing Screw (x3)
- Switch Housing
- Blade Balancing Kit
- Blade (x3)
- Blade Arm (x3)
- Hardware Kit
- Owner’s Manual
HARDWARE CONTENTS
- AA. Wire Connector (x3)
- BB. Blade Screw (x9)
- CC. Blade Washer (x9)
- DD. Pull Chain Extension
- JJ. Secondary Support Screw
- KK. Support Washer
- LL. Screw Cap (x9)
- MM. Secondary Spring Washer
Note: Some extra hardware has been included. The quantity listed above is the number required for installation.
TOOLS REQUIRED (not included)
Tools required for assembly: Electrical tape, Phillips Screwdriver,
Pliers, Safety Glasses, Step Ladder, Wire Cutters and Wire Strippers
Helpful Tools: AC Tester Light, Tape Measure, and Wiring Handbook
DIMENSION REFERENCE
MOUNTING OPTIONS
Two Mounting Options
Choose one of the following mounting options:
Downrod Mount is best suited for ceilings 8 ft. or higher. For taller ceilings
you may want to use a longer downrod (not included).
Angled Ceiling Mount is best suited for angled or vaulted ceilings. A longer
downrod is sometimes necessary to ensure proper blade clearance from the
ceiling. If using the angle mount, check to ensure the ceiling angle is not
steeper than 16°.
SAFETY INSTRUCTIONS
READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN INSTALLING THE FAN AND SAVE INSTRUCTIONS.
CAUTION:
- All set screws of the fan must be checked and retightened where necessary before installation.
- To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning fan. Do not insert foreign objects in between rotating fan blades.
- Before changing the fan direction, turn off the fan and wait for the fan blades to stop completely.
- The safeguards provided by these safety instructions and by the separate installation instructions are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person(s) installing, caring for and operating the fan.
- The fan weight is Net Weight: 12.28 lb (5,57kg). Be sure the outlet box (not included) is securely attached to the building structure and is marked “Acceptable For Fan Support”. Failure to do so can result in serious injury.
WARNING
- To avoid risk of electric shock, be sure to shut off power at the main fuse or circuit breaker box before installing or servicing this fixture. Turning off the electrical power by using the light switch is not sufficient to prevent electrical shock.
- To reduce the risk of injury, install the fan so that the blades are at least 7 feet (2.1 Meters) above the floor and at least 18 inches (0.5 Meters) from the tip of the blades to the wall.
- To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting screws provided with the outlet box.
- The installation has to be in accordance with the national electrical code, ANSI/NFPA 70-1999 and local codes. If you are unfamiliar with the methods of installing electrical wiring, seek the services of a qualified licensed electrician.
- Using a full-range dimmer switch to control fan speed will cause a loud humming noise from the fan. To reduce the risk of fire or electric shock, do NOT use a full-range dimmer switch to control the fan speed.
ASSEMBLY INSTRUCTIONS
-
Turn OFF the electrical power at the main fuse or circuit breaker.
DANGER: Failure to disconnect the power supply prior to installation may result in serious injury or death. -
Loosen all four mounting bracket screws located on the mounting bracket and completely remove the two screws from the round holes in the canopy. Save the screws for later. Remove the canopy from the mounting bracket. Then, install the mounting bracket to the outlet box (sold separately) using the screws and washers provided with the outlet box.
WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to the outlet box marked “acceptable for fan support” and use the mounting screws and washers provided with the outlet box. -
Remove the 6 Phillips-head motor screws from the top part of the motor and save the motor screws for blade arm installation.
-
Remove the downrod clip and downrod pin from the downrod. Then, loosen but do not remove the two set screws at the top of the yoke.
-
Feed the wires and braided cable coming from the yoke through the yoke cover, canopy and downrod.
-
Slide the downrod into the yoke of the motor assembly, align the holes, then re-install the downrod pin and downrod clip. Secure with the two set screws and slide the yoke cover down until it rests on top of the motor assembly.
Note: With wiring extending out of the downrod, measure 8 inches of lead wire and cut the excess wire with wire cutters (not included). Then strip 1/2” of insulation from the end of each wire.
WARNING: Do not cut braided cable. -
Install the ball end of the downrod into the opening of the mounting bracket. Rotate the downrod until the tab in the mounting bracket is seated in the slot in the downrod ball.
WARNING: The fan and/or downrod should not rotate in the mounting bracket, if installed correctly. Failure to align the slot in the downrod ball with the tab on the mounting bracket may result in fan falling causing serious injury or death.
SECONDARY HANGING SYSTEM
* **For installation in the United States:** Building codes in the U.S.A. do not require installation of a Secondary Hanging System. If desired, the braided cable can be cut and removed using wire cutters (sold separately). Skip to Step 11.
* **For installation in Canada:** In compliance with building codes in Canada, installation of the Secondary Hanging System is required.
- Feed the loop of the braided cable, preassembled to the motor assembly, up through the outlet box mounted in the ceiling.
- Install secondary support screw, secondary spring washer, and support washer partly into the side of the brace installed in the ceiling. Then lift the braided cable up and over the ceiling brace and place the open loop of the braided cable around the secondary support screw. Note: The ceiling support brace may not be accessible from below. If not, it must be accessed from above. Important: The braided cable must make a complete circle around the support brace to secure the fan.
- Tighten the secondary support screw securing the braided cable.
-
Use wire connectors to connect the fan wires to the power supply wires according to the wiring diagram and the following instructions:
- Connect the white wire from the fan to the white (neutral) supply wire.
- Connect the black and blue wires from the fan to the black (hot) supply wire.
- Connect the green wire from the downrod and mounting bracket to the bare/green (ground) supply wire.
Important: After the connections have been made, the wires should be turned upward and pushed carefully up into the outlet box. Place the black and white wire connections on opposite sides of the outlet box.
-
Raise the canopy, ensure the two mounting bracket screws are aligned with the J-shaped slots in the canopy. Then turn the canopy in a clockwise direction until the mounting bracket screws are completely engaged in the J-shaped slots. Install the two previously removed mounting bracket screws in the round holes. Securely tighten all mounting bracket screws.
-
Attach the blade to the blade arm using blade screw, blade washer, and screw cap from the hardware kit. Repeat for each blade.
-
Install the blade arm to the top side of the motor with motor screws previously removed (Step 3, page 5). Tighten with Phillips screwdriver (not included). Repeat for each blade arm.
- Remove one of the three fitter plate screws preassembled to the fitter plate and loosen the other two but do not remove. Feed the 9-pin connector through the center hole in the switch housing plate. Align the keyhole slots in the switch housing plate with the loosened screws in the fitter plate. Turn switch housing plate clockwise and replace the previously removed fitter plate screw. Tighten all screws.
- Remove the three switch housing screws from the top edge of the switch housing plate. Connect the 9-pin connector from the fitter plate to the 9-pin connector from the switch housing. Then, using the three previously removed switch housing screws, secure the switch housing to the switch housing plate.
- Attach the pull chain extension to the pull chain.
- Turn ON the electrical power at the main fuse or circuit breaker and the wall switch.
**Installation is complete.
**
OPERATING INSTRUCTIONS
-
Using a ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort.
In warmer weather, push the reverse switch left which will result in downward airflow creating a wind chill effect.
In cooler weather, push the reverse switch right which will result in upward airflow that can help move stagnant, hot air off the ceiling area.
Important: Wait for the fan to stop before moving the reverse switch. The reverse switch must be set either completely left or right in order for the fan to function correctly. If the reverse switch is set in the middle position, the fan will not operate. -
The fan pull chain has four positions to control fan speed. One pull is HIGH, two is MEDIUM, three is LOW and four turns the fan OFF.
TROUBLESHOOTING
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 8 a.m. – 5 p.m. Central, Monday – Friday.
WARNING: To reduce the risk of fire, electrical shock or personal injury, shut off the power supply to fan before you begin any maintenance tasks.
SUGGESTED REMEDY & PROBLEM
- Fan does not start:
- Make sure that the wall switch is turned ON.
- Check main and branch circuit fuses or circuit breakers.
- Check all wire connections from household supply wires to the fan.
- Make sure forward/reverse switch pushed completely left or right. Fan will not operate when switch is in the middle.
- Fan is noisy:
- Make sure all screws in motor assembly are snug, but not overtightened.
- Make sure the screws that attach the blade arms to the motor are tight.
- Make sure wire connectors are not rattling against each other or against the interior wall of the switch housing.
- Make sure wire connectors are not rattling against each other or against the interior wall of the canopy.
- Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USE a Solid State variable speed control.
- Ensure fan does not wobble excessively (see Fan wobbles solutions below).
- Fan wobbles:
- Ensure the mounting bracket is tightened securely to outlet box and outlet box is mounted firmly to ceiling joist.
- Ensure all blades are screwed firmly into blade arms.
- Ensure all blade arms are tightened securely to motor.
- Switch one blade with a blade from the opposite side. Or balance the fan using the blade balancing kit.
- If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.
LIMITED LIFETIME WARRANTY
To obtain Service, please contact the Service Department:
1-877-706-3267, 8 a.m. – 5 p.m.
Central, Monday – Friday.
Model Name: 52” Ceiling Fan Model No: 51866 – Matte Black 51867 – Pewter
-
Set forth below, the manufacturer, Hong Kong China Electric appliance Company (HKC) warrants the fan motor for this ceiling fan to be free from defects in workmanship and material for the life of the product. Also, subject to the limitations below, HKC warrants all ceiling fan parts (“ceiling fan parts” excludes the motor and parts made in whole or in part with glass) to be free from defects in workmanship and material for a period of one year after the date of purchase by the original purchaser at retail.
All claims must be made by the original purchaser, whether such purchaser purchased the product through a store or contractor. Ceiling fan part defects must be reported within the first year from the date of purchase. Parts made in whole or in part with glass and the finishes of metal and other surfaces are not warranted. -
Purchasers are responsible for all costs of removing and reinstalling the product. Any damage to any part caused by ordinary wear and tear, accident, misuse, or improper installation, is not covered by this warranty. HKC assumes no responsibility whatsoever for fan installation. Any service performed by a non-licensed electrician will render the warranty invalid.
-
HKC’s sole responsibility shall be to repair or replace the motor, parts, or product within the terms stated above. HKC shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting directly or indirectly, from any breach of warranty, express or implied, or any other failure of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you.
-
If the original purchaser ceases to own the fan, this warranty is voided.
-
Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part, HKC agrees to replace the defective part without charge, or at its option, to replace the ceiling fan with a comparable or superior model.
-
HKC’s warranties are limited to the written warranties set out in this HKC ceiling fan limited lifetime warranty. All other express and implied warranties, including, without limitation, the implied warranty of fitness for a particular purpose and the implied warranty of merchantability are disclaimed. Some states do not allow the disclaimer of implied warranties, so this disclaimer may not apply to you.
Read User Manual Online (PDF format)