PROMINENCE HOME 51639 52 Inch Indoor Ceiling Fan Owner’s Manual
- June 8, 2024
- PROMINENCE HOME
Table of Contents
- PROMINENCE HOME 51639 52 Inch Indoor Ceiling Fan
- PACKAGE CONTENTS
- HARDWARE CONTENTS
- TOOLS REQUIRED
- DIMENSION REFERENCE
- MOUNTING OPTIONS
- SAFETY INSTRUCTIONS
- ASSEMBLY INSTRUCTIONS
- OPERATING INSTRUCTIONS
- TROUBLESHOOTING
- LIMITED LIFETIME WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PROMINENCE HOME 51639 52 Inch Indoor Ceiling Fan
PACKAGE CONTENTS
Unpack your fan and check the contents. You should have the following items:
-
Canopy
-
Canopy Cover
-
Mounting Bracket Screw (x4)
-
Mounting Bracket
-
Downrod
-
Downrod Clip
-
Downrod Pin
-
Yoke Cover
-
Set Screw (x2)
-
Motor Screw (x10)
-
Motor Assembly
-
Fitter Plate
-
Fitter Plate Screw (x3)
-
Light Pan
-
Light Pan Screw (x3)
-
Light Kit
-
Glass Lens
-
Owner’s Manual
-
Hardware Kit
-
Remote Pack
-
Medallion (x5)
-
Blade Arm (x5)
-
Blade (x5)
HARDWARE CONTENTS -
Blade Screw (x15)
-
Wire Connector (x4)
-
Secondary Support Screw
-
Support Washer
-
Secondary Spring Washer
-
Blade Balancing Kit
Note: Some extra hardware has been included. The quantity listed above is the number required for installation.
HARDWARE CONTENTS
TOOLS REQUIRED
(not included)
- Tools required for assembly: Electrical tape, Phillips Screwdriver, Pliers, Safety Glasses, Step Ladder, Wire Cutters and Wire Strippers
- Helpful Tools: AC Tester Light, Tape Measure, and Wiring Handbook
DIMENSION REFERENCE
MOUNTING OPTIONS
Two Mounting Options
Choose one of the following mounting options:
- Downrod Mount is best suited for ceilings 8 ft. or higher. For taller ceilings you may want to use a longer downrod (not included).
- Angled Ceiling Mount is best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance from the ceiling. If using the angle mount, check to ensure the ceiling angle is not steeper than 10°.
SAFETY INSTRUCTIONS
READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN
INSTALLING THE FAN AND SAVE INSTRUCTIONS.
CAUTION:
- All set screws of the fan must be checked and retightened where necessary before installation.
- To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning fan. Do not insert foreign objects in between rotating fan blades.
- Before changing the fan direction, turn off the fan and wait for the fan blades to stop completely.
- The safeguards provided by these safety instructions and by the separate installation instructions are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person(s) installing, caring for and operating the fan.
- The fan weight is Net Weight: 19.29 lbs (8,75 kg). Be sure the outlet box (not included) is securely attached to the building structure and is marked “Acceptable
- For Fan Support”. Failure to do so can result in serious injury.
- This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device (if applicable).
- CAN ICES-005 (B) / NMB-005 (B)
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
- This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Please note changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
HKC-US
3350 Player’s Club Parkway, #225
Memphis, TN 38125
1-877-706-3267
WARNING:
- To avoid risk of electric shock, be sure to shut off power at the main fuse or circuit breaker box before installing or servicing this fixture. Turning off the electrical power by using the light switch is not sufficient to prevent electrical shock.
- To reduce the risk of injury, install the fan so that the blades are at least 7 feet (2.1 Meters) above the floor and at least 18 inches (0.5 Meters) from the tip of the blades to the wall.
- To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting screws provided with the outlet box.
- The installation has to be in accordance with the national electrical code, ANSI/NFPA 70-1999 and local codes. If you are unfamiliar with the methods of installing electrical wiring, seek the services of a qualified licensed electrician.
- Using a full-range dimmer switch to control fan speed will cause a loud humming noise from the fan. To reduce the risk of fire or electric shock, do NOT use a full-range dimmer switch to control the fan speed.
ASSEMBLY INSTRUCTIONS
-
Turn OFF the electrical power at the main fuse or circuit breaker.
DANGER: Failure to disconnect the power supply prior to installation may result in serious injury or death. -
Loosen all four mounting bracket screws and completely remove the two screws from the round holes in the canopy. Then remove mounting bracket from the canopy and save them for later. Remove the canopy from the mounting bracket. Install the mounting bracket to the outlet box (sold separately) using the screws and washers provided with the outlet box.
WARNING: To reduce the risk of fire electric shock, or personal injury, mount to the outlet box marked “acceptable for fan support” and use the mounting screws and washers provided with the outlet box. -
Remove the ten motor screws from the top of the motor assembly. Secure the blade arm to motor assembly using two motor screws. Securely tighten each blade arm before moving to the next. Drop three blade screws into the holes in each blade arm.
-
Remove the downrod clip and downrod pin from the downrod. Then loosen but do not remove the two set screws in the yoke at the top of the motor assembly.
-
Insert the downrod through the canopy and yoke cover. Feed the wires and braided cable from the fan through the downrod.
-
Slide the downrod into the yoke of the motor assembly, align the holes, then re-install the downrod pin and downrod clip. Secure with the two set screws and slide the yoke cover down until it rests on top of the motor assembly.
Note: With wiring extending out of the downrod, measure 8 inches of lead wire and cut the excess wire with wire cutters (not included). Then strip 1/2” of insulation from the end of each wire.
WARNING: Do not cut braided cable. -
Install the ball end of the downrod into the opening of mounting bracket. Rotate the downrod until the tab in the mounting bracket is seated in the slot in the downrod ball.
WARNING : The fan and/or downrod should not rotate in the mounting bracket, if installed correctly. Failure to align the slot in the downrod ball with the tab on the mounting bracket may result in fan falling causing serious injury or death -
Insert the receiver, antenna first, into the mounting bracket with the flat side facing the ceiling.
Note: The receiver will rest directly on top of the downrod.
Note: There is an adhesive sticker on one of the antennas connected to the receiver. For best results, stick the antenna to the ceiling.
SECONDARY HANGING SYSTEM
For installation in the United States: Building codes in the U.S.A. do not require installation of a Secondary Hanging System. If desired, the braided cable can be cut and removed using wire cutters (sold separately). Skip to Step 12.
For installation in Canada: In compliance with building codes in Canada, installation of the Secondary Hanging System is required. -
Feed the loop of the braided cable, preassembled to the motor assembly, up through the outlet box mounted in the ceiling.
-
Install secondary support screw, secondary spring washer, and support washer partly into the side of the brace installed in the ceiling. Then lift the braided cable up and over the ceiling brace and place the open loop of the braided cable around the secondary support screw. Note: The ceiling support brace may not be accessible from below. If not, it must be accessed from above. Important: The braided cable must make a complete circle around the support brace to secure the fan.
-
Tighten the secondary support screw securing the braided cable.
-
Use wire connectors and push-in connectors to connect the receiver and fan wires to the supply wires from outlet box according to the wiring diagram and the following instructions:
- Connect the Green wires from the fan and the mounting bracket to the Bare/Green (ground) supply wire.
- Connect the Blue wire (FOR LIGHT) from the receiver to the Blue fan wire.
- Connect the Black wire (TO MOTOR L) from the receiver to the Black fan wire.
- Connect the White wire (TO MOTOR N) from the receiver to the White fan wire.
- Push the Black (Hot/Power) supply wire into the empty wire hole in push-in wire connector preassembled to the Black wire (AC IN L).
- Push the White (neutral) supply wire into the empty wire hole in push-in wire connector preassembled to the White wire (AC IN N).
Important: After the connections have been made, the connected wires should be turned upward and pushed carefully up into the outlet box. Place the black and white wire connections on opposite sides of the outlet box.
-
Raise the canopy, ensure the two mounting bracket screws are aligned with the J-shaped slots in the canopy. Then turn the canopy in a clockwise direction until the mounting bracket screws are completely engaged in
the J-shaped slots. Install the two previously removed mounting bracket screws in the round holes. Securely tighten all mounting bracket screws. -
Partially insert the three blade screws, preassembled in the blade arms, through the blade and into the medallion. Tighten each blade screw, starting with the one in the middle. Repeat this step for the remaining blades and blade arms.
-
Loosen two and completely remove one light pan screw from the round hole in the light kit. Save the light pan screw for later. Twist the light kit in a counterclockwise direction and remove the light kit from the light pan.
-
Remove one of the three fitter plate screws preassembled to the fitter plate and loosen the other two but do not remove. Feed the 9-pin connector through the center hole in the light pan. Align the slotted holes in the light pan with the loosened screws in the fitter plate. Turn light pan clockwise and replace the previously removed fitter plate screw. Tighten all screws.
-
Connect the single-pin connectors from the light kit –blue to black and white to white. Then, connect the 9-pin connector from the light kit and the fitter plate. Finally, lift the two keyhole slots in the light kit over the two loosened light pan screws. Then, turn the light kit clockwise and re-install the previously removed light pan screw. Tighten all three light pan screws.
-
Lift the glass lens into the light pan and twist in a clockwise direction until it is secure.
-
Remove the battery door from the back of the remote using a flat-head screwdriver (not included). Insert the two CR2032 batteries into the remote; ensure the positive pole of the batteries face up (as pictured) and then replace the battery door.
Note: Your fan and wall control/remote were synced at the factory. If the wall control does not operate the fan, see TROUBLESHOOTING -
If desired, the wall bracket can be installed to the wall using the two mounting screws. Store the remote In the wall bracket when not in use.
-
Turn ON the electrical power at the main fuse or circuit breaker and the wall switch. Installation is complete.
OPERATING INSTRUCTIONS
-
To operate the fan using the remote, press and release the following buttons:
- Fan Off – Turns the power to fan off.
- Light On/Off – Turns the light on and off. Press and hold to dim or brighten lights (for dimmable bulbs only).
- High Speed – Turns on fan at high speed.
- Light Delay – Light stays on for 60 seconds to allow for safe exit from room. Tap Light Delay once to activate. Fan light blinks once to confirm Light Delay is active. Press any button to cancel.
- Medium Speed – Turns on fan at medium speed.
- Variable Breeze – Simulates a breeze in nature. Press and hold button to activate. Press any fan speed button to cancel.
- Low Speed – Turns on fan at low speed.
- Home Shield – Simulates occupancy while away from home. Fan remains off and the light randomly turns on for a minimum of five times and a maximum of 20 minutes. The light remains off for 60 minutes between events. Press and hold button to activate. Light will blink twice to confirm Home Sheild is active. Press any button to cancel.
- LED indicator should illuminate when any remote button is pressed. If not, replace the DC3V, CR2032 batteries.
-
LEARN – Syncs remote to receiver (see TROUBLESHOOTING for instructions).
Note : To access LEARN button, remove battery door from back of the remote using a flat-head screwdriver. -
To control the fan via WiFi remote, download the Fansio® app to your smartphone. Load the app and follow the in-app instructions to sync with the remote. You will need your personal WiFi network name and password.
Note: The remote receiver is compatible with 2.4 gHz only and will not work with 5.0 gHz routers. -
Using a ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort.
- In warmer weather , push the reverse switch left which will result in downward airflow creating a wind chill effect.
- In cooler weather, push the reverse switch right which will result in upward airflow that can help move stagnant, hot air off the ceiling area.
- Important: Wait for the fan to stop before moving the reverse switch. The reverse switch must be set either completely left or right in order for the fan to function correctly. If the reverse switch is set in the middle position, the fan will not operate.
TROUBLESHOOTING
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 8 a.m. – 5 p.m. Central, Monday – Friday.
LIMITED LIFETIME WARRANTY
To obtain Service, please contact the Service Department:
1-877-706-3267, 8 a.m. – 5 p.m.
Central, Monday – Friday.
Model Name : 52” Ceiling Fan
Model No: 51639 – Matte Black
51640 – Pewter 51641 – Blue
Set forth below, the manufacturer, Hong Kong China Electric appliance Company
(HKC) warrants the fan motor for this ceiling fan to be free from defects in
workmanship and material for the life of the product. Also, subject to the
limitations below, HKC warrants all ceiling fan parts (“ceiling fan parts”
excludes the motor and parts made in whole or in part with glass) to be free
from defects in workmanship and material for a period of one year after the
date of purchase by the original purchaser at retail. All claims must be made
by the original purchaser, whether such purchaser purchased the product
through a store or contractor. Ceiling fan part defects must be reported
within the first year from the date of purchase. Parts made in whole or in
part with glass and the finishes of metal and other surfaces are not
warranted. Purchasers are responsible for all costs of removing and
reinstalling the product. Any damage to any part caused by ordinary wear and
tear, accident, misuse, or improper installation, is not covered by this
warranty. HKC assumes no responsibility whatsoever for fan installation. Any
service performed by a non-licensed electrician will render the warranty
invalid. HKC’s sole responsibility shall be to repair or replace the motor,
parts, or product within the terms stated above. HKC shall not be liable for
any loss or damage of any kind, including any incidental or consequential
damages resulting directly or indirectly, from any breach of warranty, express
or implied, or any other failure of this product. Some states do not allow the
exclusion or limitation of incidental or consequential damages so this
limitation may not apply to you. If the original purchaser ceases to own the
fan, this warranty is voided. Should the purchaser encounter a problem with
your fan related to defects in workmanship or materials within the warranty
period associated with the defective part, HKC agrees to replace the defective
part without charge, or at its option, to replace the ceiling fan with a
comparable or superior model. HKC’s warranties are limited to the written
warranties set out in this HKC ceiling fan limited lifetime warranty. All
other express and implied warranties, including, without limitation, the
implied warranty of fitness for a particular purpose and the implied warranty
of merchantability are disclaimed. Some states do not allow the disclaimer of
implied warranties, so this disclaimer may not apply to you.