PROMINENCE HOME 51595 Indoor Ceiling Fan Owner’s Manual
- June 8, 2024
- PROMINENCE HOME
Table of Contents
- PROMINENCE HOME 51595 Indoor Ceiling Fan
- PACKAGE CONTENTS
- HARDWARE CONTENTS
- TOOLS REQUIRED
- DIMENSION REFERENCE
- MOUNTING OPTIONS
- SAFETY INSTRUCTIONS
- ASSEMBLY INSTRUCTIONS
- OPERATING INSTRUCTIONS
- TROUBLESHOOTING
- LIMITED LIFETIME WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PROMINENCE HOME 51595 Indoor Ceiling Fan
If a problem cannot be remedied or you are experiencing difficulty in
installation, please contact the service department.
1-877-459-3267 8 a.m.-5 p.m Central,
Monday-Friday
Keeping You Cool Is What We Do Best!
PACKAGE CONTENTS
Unpack your fan and check the contents. You should have the following items:
-
Canopy
-
Canopy Cover
-
Mounting Bracket Screw (x4)
-
Mounting Bracket
-
Downrod
-
Downrod Clip
-
Downrod Pin
-
Yoke Cover
-
Set Screw (x2)
-
Closemount Screw (x3)
-
Motor Assembly
-
Motor Screw (x10)
-
Switch Housing
-
Switch Housing Cap
-
Switch Housing Screw (x3)
-
Light Kit
-
Hex Nut
-
Rubber Washer
-
Finial Cap
-
Finial
-
Glass Bowl
-
Owner’s Manual
-
Hardware Kit
-
Blade Arm (x5)
-
Blade (x5)
-
E26-base LED Bulb (x2)
HARDWARE CONTENTS -
Blade Screw (x15)
-
Blade Washer (x15)
-
Wire Connector (x3)
-
Pull Chain Extension (x2)
-
Secondary Support Screw
-
Support Washer
-
Secondary Spring Washer
-
Plug Button
-
Blade Balancing Kit
Note: Some extra hardware has been included. The quantity listed above is the number required for installation.
HARDWARE CONTENTS
TOOLS REQUIRED
(not included)
-
Tools required for assembly: Electrical tape, Phillips Screwdriver, Pliers, Safety Glasses, Step Ladder, Wire Cutters and Wire Strippers
-
Helpful Tools: AC Tester Light, Tape Measure, and Wiring Handbook
DIMENSION REFERENCE
A. 19.16 in. B. 11.8 in. C. 11.53 in. D. 5.13 in.
MOUNTING OPTIONS
Three Mounting Options
Choose one of the following mounting options:
- Closemount is best suited for ceilings lower than 8 feet. It does not utilize the downrod.
- Downrod Mount is best suited for ceilings 8 ft. or higher. For taller ceilings you may want to use a longer downrod (not included).
- Angled Ceiling Mount is best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance from the ceiling.
- If using the angle mount, check to ensure the ceiling angle is not steeper than 16°.
SAFETY INSTRUCTIONS
READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN
INSTALLING THE FAN AND SAVE INSTRUCTIONS.
CAUTION:
- All set screws of the fan must be checked and retightened where necessary before installation.
- To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning fan. Do not insert foreign objects in between rotating fan blades.
- Before changing the fan direction, turn off the fan and wait for the fan blades to stop completely.
- The safeguards provided by these safety instructions and by the separate installation instructions are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person(s) installing, caring for and operating the fan.
- The fan weight is Net Weight: 17.02 lbs (7,72 kg). Be sure the outlet box (not included) is securely attached to the building structure and is marked “Acceptable
- For Fan Support”. Failure to do so can result in serious injury.
- This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device (if applicable).
- CAN ICES-005 (B) / NMB-005 (B)
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
- This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Please note changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
HKC-US
3350 Player’s Club Parkway, #225
Memphis, TN 38125
1-877-706-3267
WARNING:
- To avoid risk of electric shock, be sure to shut off power at the main fuse or circuit breaker box before installing or servicing this fixture. Turning off the electrical power by using the light switch is not sufficient to prevent electrical shock.
- To reduce the risk of injury, install the fan so that the blades are at least 7 feet (2.1 Meters) above the floor and at least 18 inches (0.5 Meters) from the tip of the blades to the wall.
- To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting screws provided with the outlet box.
- The installation has to be in accordance with the national electrical code, ANSI/NFPA 70-1999 and local codes. If you are unfamiliar with the methods of installing electrical wiring, seek the services of a qualified licensed electrician.
- Using a full-range dimmer switch to control fan speed will cause a loud humming noise from the fan. To reduce the risk of fire or electric shock, do NOT use a full-range dimmer switch to control the fan speed.
ASSEMBLY INSTRUCTIONS
-
Turn OFF the electrical power at the main fuse or circuit breaker.
DANGER: Failure to disconnect the power supply prior to installation may result in serious injury or death. -
Loosen all four mounting bracket screws and completely remove the two screws from the round holes in the canopy. Then remove mounting bracket from the canopy and save them for later. Remove the canopy from the mounting bracket. Install the mounting bracket to the outlet box (sold separately) using the screws and washers provided with the outlet box.
WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to the outlet box marked “acceptable for fan support” and use the mounting screws and washers provided with the outlet box. -
Remove the ten motor screws and five motor blocks from the underside of the motor. Discard the motor blocks but save the motor screws for blade arm installation.
-
CLOSEMOUNT INSTALLATION (Optional) –
- a. Remove the three Phillips-head closemount screws from the top of the motor assembly.
- b. Remove the canopy cover from the bottom of the canopy.
- c. Align the holes in the bottom of the canopy with the screw holes in the top of the motor assembly. The larger holes in the canopy will encompass the three pre-installed screws.
- d. Secure the canopy to the top of the motor assembly with the three closemount screws.
- e. Hang the fan on the hook of the mounting bracket. Proceed to Step 9.
-
DOWNROD MOUNT – Remove the downrod clip and downrod pin from the downrod. Then loosen but do not remove the two set screws in the yoke at the top of the motor assembly.
-
Feed the wires and braided cable coming from the yoke through the yoke cover, canopy, and downrod.
-
Insert the downrod into the yoke and reinstall the downrod pin and downrod clip. Then retighten the two set screws.
Note: With wiring extending out of the downrod, measure 8 inches of lead wire and cut the excess wire with wire cutters (not included). Then strip 1/2” of insulation from the end of each wire.
WARNING: Do not cut braided cable. -
Install the ball end of the downrod into the opening of the mounting bracket. Rotate the downrod until the tab in the mounting bracket is seated in the slot in the downrod ball.
WARNING: The fan and/or downrod should not rotate in the mounting bracket, if installed correctly. Failure to align the slot in the downrod ball with the tab on the mounting bracket may result in fan falling causing serious injury or death.
SECONDARY HANGING SYSTEM
For installation in the United States: Building codes in the U.S.A. do not require installation of a Secondary Hanging System. If desired, the braided cable can be cut and removed using wire cutters (sold separately). Skip to Step 12.
For installation in Canada: In compliance with building codes in Canada, installation of the Secondary Hanging System is required. -
Feed the loop of the braided cable, preassembled to the motor assembly, up through the outlet box mounted in the ceiling.
-
Install secondary support screw, secondary spring washer, and support washer partly into the side of the brace installed in the ceiling. Then lift the braided cable up and over the ceiling brace and place the open loop of the braided cable around the secondary support screw. Note: The ceiling support brace may not be accessible from below. If not, it must be accessed from above. Important: The braided cable must make a complete circle around the support brace to secure the fan.
-
Tighten the secondary support screw securing the braided cable.
-
Use wire connectors to connect the fan wires to the power supply wires according to the wiring diagram and the following instructions:
- Connect the white wire from the fan to the white (neutral) supply wire.
- Connect the black and blue wires from the fan to the black (hot) supply wire.
- Connect the green wire from the downrod and mounting bracket to the bare/green (ground) supply wire. Note: The downrod is not used for closemount installation, so there will only be two green wires to connect.
Note: If a second hot/power wire is available from the outlet box, connect it to the blue (light power) fan wire for separate fan and light switches.
Important: After the connections have been made, the wires should be turned upward and pushed carefully
up into the outlet box. Place the black and white wire connections on opposite sides of the outlet box.
-
Raise the canopy, ensure the two mounting bracket screws are aligned with the J-shaped slots in the canopy. Then turn the canopy in a clockwise direction until the mounting bracket screws are completely engaged in the J-shaped slots. Install the two previously removed mounting bracket screws in the round holes. Securely tighten all mounting bracket screws.
-
Partially insert the blade screws along with the blade washers through the blade and into the blade arm. Tighten each blade screw with a Phillips screwdriver (not included), starting with the one in the middle. Repeat this step for the remaining blades and blade arms.
-
Install the blade arm to the underside of the motor assembly with previously removed motor screws. Tighten each blade arm completely before moving to the next.
-
Remove the three switch housing screws from the top edge of the switch housing cap. Then, connect the single-pin connectors from the switch housing to the single-pin connectors from the light kit — blue to black and white to white. Then, using the three previously removed switch housing screws, secure the light kit to the switch housing.
-
Install the E26-base bulbs into the sockets on the light kit.
Important: Make sure to allow the bulbs and light kit to cool before replacing the bulbs. -
Remove the preassembled finial, finial cap, hex nut and rubber washer from the light kit. Feed the pull chain coming from the grommet in the light kit through the off-center hole in the glass bowl. Feed the pull chain coming from the center of the light kit through the center hole in the glass bowl. Lift the glass bowl onto the threaded rod at the bottom of the light kit. Secure glass bowl with rubber washer and hex nut. Then attach finial cap and finial. Proceed to Step 22.
-
NO LIGHT KIT OPTION (OPTIONAL)
Remove the light kit from the switch housing cap by removing the hex nut and washer from inside the switch housing cap. Insert plug button into the center of the switch housing cap. -
Remove the three switch housing screws from the top edge of the light kit. Install the switch housing cap to the bottom of the switch housing with the three switch housing screws.
-
Attach the pull chain extension.
-
Attach pull chain extensions to the pull chains. Note: The pull chain in the center of the light kit controls the light.
-
Turn on the electrical power at the main fuse or circuit breaker and the wall switch.
Installation is complete.
OPERATING INSTRUCTIONS
-
Using a ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort.
In warmer weather, push the reverse switch down which will result in downward airflow creating a wind chill effect.
In cooler weather, push the reverse switch up which will result in upward airflow that can help move stagnant, hot air off the ceiling area.
Important: Wait for the fan to stop before moving the reverse switch. The reverse switch must be set either completely up or down in order for the fan to function correctly. If the reverse switch is set in the middle position, the fan will not operate. -
The fan pull chain has four positions to control fan speed. One pull is HIGH, two is MEDIUM, three is LOW and four turns the fan OFF. The light pull chain turns the light ON and OFF.
TROUBLESHOOTING
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 8 a.m. – 5 p.m. Central, Monday – Friday.
LIMITED LIFETIME WARRANTY
To obtain Service, please contact the Service Department:
1-877-706-3267, 8 a.m. – 5 p.m.
Central, Monday – Friday.
Model Name: 52” Ceiling Fan
Model No: 51595 – Espresso
51596 – Brushed Nickel
Set forth below, the manufacturer, Hong Kong China Electric appliance Company (HKC) warrants the fan motor for this ceiling fan to be free from defects in workmanship and material for the life of the product. Also, subject to the limitations below, HKC warrants all ceiling fan parts (“ceiling fan parts” excludes the motor and parts made in whole or in part with glass) to be free from defects in workmanship and material for a period of one year after the date of purchase by the original purchaser at retail. All claims must be made by the original purchaser, whether such purchaser purchased the product through a store or contractor. Ceiling fan part defects must be reported within the first year from the date of purchase. Parts made in whole or in part with glass and the finishes of metal and other surfaces are not warranted. Purchasers are responsible for all costs of removing and reinstalling the product. Any damage to any part caused by ordinary wear and tear, accident, misuse, or improper installation, is not covered by this warranty. HKC assumes no responsibility whatsoever for fan installation. Any service performed by a non-licensed electrician will render the warranty invalid. HKC’s sole responsibility shall be to repair or replace the motor, parts, or product within the terms stated above. HKC shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting directly or indirectly, from any breach of warranty, express or implied, or any other failure of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you. If the original purchaser ceases to own the fan, this warranty is voided. Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part, HKC agrees to replace the defective part without charge, or at its option, to replace the ceiling fan with a comparable or superior model. HKC’s warranties are limited to the written warranties set out in this HKC ceiling fan limited lifetime warranty. All other express and implied warranties, including, without limitation, the implied warranty of fitness for a particular purpose and the implied warranty of merchantability are disclaimed. Some states do not allow the disclaimer of implied warranties, so this disclaimer may not apply to you.