PLANET IGS-4215-Series Industrial Managed Gigabit Switch Installation Guide

June 13, 2024
PLANET

PLANET IGS-4215-Series Industrial Managed Gigabit Switch

PLANET-IGS-4215-Series-Industrial-Managed-Gigabit-Switch-
product

Product Information

The Industrial L2/L4 Managed Gigabit Switch is a high-performance network switch designed for industrial use. It is available in multiple models:

  • IGS-4215-4P4T: Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T Managed Switch
  • IGS-4215-4P4T2S: Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
  • IGS-4215-8P2T2S: Industrial 8-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
  • IGS-4215-4UP4T2S: Industrial 4-Port 10/100/1000T 802.3bt PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
  • IGS-4215-8UP2T2S: Industrial 8-Port 10/100/1000T 802.3bt PoE + 2-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch

Product Usage Instructions

Package Contents

When you receive the Industrial Managed PoE+ Switch, please ensure that the package includes the following items:

  • The Industrial Managed PoE+ Switch x 1
  • Quick Installation Guide Sheet x 1
  • RS232 to RJ45 Console Cable x 1
  • Dust Caps (RJ45 and SFP) – quantity varies based on the model
  • DIN-rail Kit x 1
  • Wall Mounting Kit x 1

If any item is missing or damaged, please contact your local reseller for a replacement.

Requirements

To use the Industrial Managed PoE+ Switch, you need the following:

  • Workstations running Windows XP/2003/Vista/7/8/10/2008/10/11, MAC OS X or later, Linux, UNIX, or other platforms compatible with TCP/IP protocols
  • Workstations installed with Ethernet NIC (Network Interface Card)
  • Serial Port Connection (Terminal) – Workstations with COM Port (DB9) or USB-to-RS232 converter
  • Terminal emulator software installed on the Workstations (e.g., Tera Term, PuTTY, Hyper Terminal)
  • Serial cable – one end attached to the RS232 serial port, and the other end attached to the RJ45 console port of the Industrial Managed PoE+ Switch
  • Ethernet Port Connection – Network cables (UTP) with RJ45 connectors
  • PC with a Web browser (recommended: Google Chrome or above) to access the Industrial Managed PoE+ Switch

If the Web interface of the Industrial Managed PoE+ Switch is not accessible, please turn off the anti-virus software or firewall and try again.

Wiring the Power Inputs

Follow the steps below to wire the power inputs of the Industrial Managed PoE+ Switch:

  1. Ensure that the switch is powered off and disconnected from the power source.
  2. Connect the power input cables to the appropriate power terminals on the switch.
  3. If required, ground the device by connecting a grounding wire to the grounding terminal.
  4. Once the power inputs are properly wired, you can proceed to the terminal setup.

For detailed instructions on terminal setup and other features of the Industrial Managed PoE+ Switch, refer to the user manual.

Package Contents

Thank you for purchasing PLANET L2/L4 Managed Gigabit Switch. The descriptions of these models are shown below:

IGS-4215-4P4T| Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T Managed Switch
---|---
IGS-4215-4P4T2S| Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
IGS-4215-8P2T2S| Industrial 8-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
IGS-4215-4UP4T2S| Industrial 4-Port 10/100/1000T 802.3bt PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
IGS-4215-8UP2T2S| Industrial 8-Port 10/100/1000T 802.3bt PoE + 2-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch

  • Industrial Managed PoE+ Switch” is used as an alternative name in this Quick Installation Guide.
  • Open the box of the Industrial Managed PoE+ Switch and carefully unpack it. The box should contain the following items:
  • The Industrial Managed PoE+ Switch x 1
  • Quick Installation Guide Sheet x 1
  • RS232 to RJ45 Console Cable x 1
  • Dust Caps
Model RJ45 Dust Caps SFP Dust Caps
IGS-4215-4P4T 9
IGS-4215-4P4T2S 9 2
IGS-4215-8P2T2S 11 2
IGS-4215-4UP4T2S 9 2
IGS-4215-8UP2T2S 11 2
  • DIN-rail Kit x 1
  • Wall Mounting Kit x 1
  • If any item is found missing or damaged, please contact your local reseller for replacement.

Requirements

  • Workstations running Windows XP/2003/Vista/7/8/10/2008/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP proto-cols.
  • Workstations are installed with Ethernet NIC (Network Interface Card)
  • Serial Port Connection (Terminal)
  • The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
  • The above Workstations have been installed with terminal emulator, such as Tera Term, PuTTY or Hyper Terminal included in Windows XP/2003.
  • Serial cable — one end is attached to the RS232 serial port, while the other ends to the RJ45 console port of the Industrial Managed PoE+ Switch.

Ethernet Port Connection

  • Network cables — Use standard network (UTP) cables with RJ45 connec-tors.
  • The above PC is installed with Web browser.
  • It is recommended to use Google Chrome or above to access the Industrial Managed PoE+ Switch. If the Web interface of the Industrial Managed PoE+ Switch is not accessible, please turn off the anti-virus software or firewall and then try it again.

Wiring the Power Inputs

  • The Upper Panel of the Industrial Managed PoE+ Switch indicates a DC inlet power socket and consists of one terminal block connector within 6 contacts. Please follow the steps below to insert the power wire.
  1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1 or 5 and 6 for Power 2.
  2. Tighten the wire-clamp screws for preventing the wires from loosening.
Item Positive (+) Pin Negative (-) Pin
IGS-4215 Series Pin 1/5 Pin 2/6
  1. The wire gauge for the terminal block should be in the range from 12 to 24 AWG.
  2. Please check the wire AWG Ampere specification before connecting PLANET Industrial Managed POE+ Switch.

PWR1 and PWR2 must provide exactly the same DC voltage for power load balance while operating with dual power input.

Grounding the Device

Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device.

Terminal Setup

To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to the RJ45 type of the console port of the Industrial Managed PoE+ Switch.

A terminal program is required to make the software connection to the Industrial Managed PoE+ Switch.

  1. Run terminal program on the OS.
  2. When the following screen appears, make sure that the COM port should be configured as:
  • Baud: 115200
  • Data bits: 8
  • Parity: None
  • Stop bits: 1
  • Flow   control: None

Logging on to the Console

  • Once the terminal is connected to the device, power on the Industrial Managed PoE+ Switch and the terminal will display “running testing procedures”.
  • Then, the following message asks to log in user name and password.
  • The factory default user name and password are shown as follows, and the login screen in Figure 4-3 appears.
  • The following console screen is based on the IGS-4215-8P2T2S. The display of the other IGS-4215 PoE Series is the same as that of the IGS-4215-8P2T2S.
  • Username: admin
  • Password: admin
  • The user can now enter commands to manage the Industrial Managed PoE+ Switch. For a detailed description of the commands, please refer to the following chapters.
  1. For security reason, please change and memorize the new password after this first setup.
  2. Only accept command in lowercase letter under console inter-face.

Configuring IP Address via Console

  • The Industrial Managed PoE+ Switch is shipped with default IP address as follows:
  • IP Address: 192.168.0.100
  • Subnet Mask: 255.255.255.0
  • To check the current IP address or modify a new IP address for the Industrial Managed PoE+ Switch, please use the procedures as follows:

Show the current IP address

  1. At the “IGS-4215-8P2T2S#” prompt, enter “show ip”.
  2. The screen displays the current IP address, subnet mask and gateway as shown in Figure 4-4.
    • Configuration of the IP Address
  3. At the “IGS-4215-8P2T2S #” prompt, enter “configure”.
  4. At the “IGS-4215-8P2T2S (config)#” prompt, enter the following command and press as shown in Figure 4-5.
    • IGS-4215-8P2T2S (config)# ip address 192.168.1.100 mask 255.255.255.0
    • IGS-4215-8P2T2S (config)# ip default-gateway 192.168.1.254
    • The previous command would apply the following settings for the Industrial Managed PoE+ Switch.
  5. Repeat Step 1 to check if the IP address has changed.
  • If the IP is successfully configured, the Industrial Managed PoE+ Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed PoE+ Switch through the new IP address.

Storing Current Switch Configuration

  1. At the “IGS-4215-8P2T2S#” prompt, enter “copy running-config startup-config” as shown in Figure 4-6.

If you are not familiar with console command or the related parameter, enter “?” anytime in console to get the help descrip-tion.

Sarting Web Management

  • The following shows how to start up the Web Management of the Industrial Managed PoE+ Switch. Note the Industrial Managed PoE+ Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
  • For example, the default IP address of the Industrial Managed PoE+ Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.

Logging in to the Industrial Managed PoE+ Switch

  1. Use Google Chrome or above Web browser and enter IP address https://192.168.0.100 to access the Web interface.
  2. When the following dialog box appears, please enter the default user name and password “admin”. The login screen in Figure 5-2 appears.
    • Default   Username: admin
    • Default Password: admin
  3. After entering the password, the main screen appears as Figure 5-3 shows.

The following web screen is based on the IGS-4215-8P2T2S. The display of the other IGS-4215 PoE Series is the same as that of the IGS-4215-8P2T2S.

The Switch Menu on the left of the Web page lets you access all the commands and statistics the Industrial Managed PoE+ Switch provides.

Now, you can use the Web management interface to continue the Switch management. Please refer to the user’s manual for more.
Saving Configuration via Web
To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot.

  1. Click the Save icon on the top Switch Menu bar.
  2. Press the “Apply” button to save running configuration to start up configuration.

Recovering Back to Default Configuration

IP Address has been changed or admin password has been forgotten

  • To reset the IP address to the default IP Address “192.168.0.100” or reset the login password to default value, press the hardware-based reset button on the front panel for about 10 seconds.
  • After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx.

Customer Support

  • Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.

PLANET online FAQs:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PLANET User Manuals

Related Manuals