CORBETT 356-21-VGL Three Light Semi Flush Mount Instruction Manual
- June 13, 2024
- CORBETT
Table of Contents
CORBETT 356-21-VGL Three Light Semi Flush Mount
Product Information
The product is a lighting fixture manufactured by Hudson Valley Lighting Group, which includes brands such as Troy Lighting, Mitzi, and Corbett Lighting. It comes with various parts and hardware for installation and assembly.
- Mounting Plate (A): Used to mount the fixture.
- Mounting Screws (B): Screws used for attaching the mounting plate.
- Screw Collar (I): A collar that holds the fixture in place.
- Collar Loop (H): A loop used in conjunction with other parts for assembly.
- Nipple (C): A threaded pipe used to connect different parts of the fixture.
- Hex Nut (E): A nut used for securing parts.
- Tooth Washer (D): A washer used in conjunction with a nipple.
- Canopy (J): The decorative cover that conceals the electrical connections.
- Chain Link (K): A link used for hanging the fixture.
- Fixture Assembly (L): The fully assembled lighting fixture.
- Bulb (M): The recommended type of bulb for the fixture is an 8-watt LED, type G lamp.
Product Usage Instructions
- Begin by attaching the mounting plate (A) to the desired location using the provided mounting screws (B).
- Connect the nipple (C) to the mounting plate (A) and secure it using a collar loop (H).
- Attach the screw collar (I) to the nipple (C) and tighten it securely.
- Connect the canopy (J) to the collar loop (H) using a hex nut (E).
- Assemble the fixture by connecting the chain link (K), collar loop (H), nipple (C), and mounting plate (A).
- Secure the fixture assembly (L) to the canopy (J) using the screw collar (I).
- Ensure proper electrical safety by connecting the ground wire using a ground screw (F). Never connect the ground wire to the hot wire to avoid serious injury or death.
- Make electrical connections by following proper wiring guidelines. Use SPT wire with no writings for neutral connections and SPT wire with writings for hot connections. Use wire nuts (G) for secure connections.
- Double-check for any exposed wires or strands that could cause a dangerous short circuit.
- Install the recommended 8-watt LED, type G lamp (M) into the socket of the fixture assembly (L). Do not exceed the recommended wattage.
For any replacement parts, refer to the provided part numbers:
- Canopy: HDW-56CPY-56
- Chain Link: HDW-56CHN-56
WARNING/CAUTION
-
DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
-
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN. -
CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM.
-
WASH HANDS AFTER USE.
-
UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY
-
DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
-
PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.
FIXTURE INSTALLATION
-
Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
-
Remove the SCREW COLLAR (I) from the COLLAR LOOP (H). Fully thread the NIPPLE (C) onto the COLLAR LOOP (H). Thread the HEX NUT (E) onto the NIPPLE (C) along with TOOTH WASHER (D).
Then thread the NIPPLE (C) unto the MOUNTING PLATE (A). Adjust the NIPPLE (C) so that the threads of the COLLAR LOOP (H) extends 1″ beyond the CANOPY (J). Secure using HEX NUT (E). -
Insert the COLLAR LOOP (H) into the CANOPY (J) and secure using the SCREW COLLAR (I).
-
Open the CHAIN LINK (K) and attach to the FIXTURE ASSEMBLY (L) and COLLAR LOOP (H). Feed the wires through the CHAIN LINK (K) , COLLAR LOOP (H), NIPPLE (C), and MOUNTING PLATE (A).
-
Remove the SCREW COLLAR (I) from the COLLAR LOOP (H) then let the SCREW COLLAR (I) and CANOPY (J) slide through the CHAIN LINK (K).
-
Cut off excess wires, and strip the insulation off the end of the leads.
-
Attach the Ground wire to the ground inside the junction box (Generally green or bare copper wire) or the GROUND SCREW (F) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
-
Connect the fixture’s SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (G).
Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT! -
Connect the fixture’s SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
-
Push the wires back into the junction box. Lift up the CANOPY (J) up to the ceiling, and screw the SCREW COLLAR (I) onto the COLLAR LOOP (H).
-
Screw the BULB (M) into the SOCKET of the FIXTURE ASSEMBLY (L). THIS FIXTURE IS RATED FOR 8 WATT LED, TYPE G LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
-
Restore power to the outlet at the breaker or fuse box.
PART(S) | REPLACEMENT PART NAME | NUMBER |
---|---|---|
A,B,C,D,E,F,G,H,I | HARDWARE KIT | HDW-356-21 |
J | CANOPY | CPY-356-21 |
K | CHAIN LINK | CHN-356-21 |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>