CORBETT 356-49-VGL Aimi 12 Light Chandelier Instruction Manual

June 13, 2024
CORBETT

CORBETT 356-49-VGL Aimi 12 Light Chandelier

CORBETT 356-49-VGL Aimi 12 Light Chandelier-product

Product Information

The product is a lighting fixture manufactured by Hudson Valley Lighting, Troy Lighting, Mitzi, and Corbett Lighting. It is designed for indoor use.

Fixture Installation

Before starting the installation process, ensure that the power is turned off at the circuit breaker.

  1. Mounting Plate (A) and Mounting Screws (B): Use the mounting plate and screws to securely attach the fixture to the ceiling or wall.
  2. Safety Cable (N) and Cable Clip (O): Use the safety cable and cable clip to provide additional support for the fixture.
  3. Screw Collar (I) and Collar Loop (H): Connect the screw collar and collar loop to secure the fixture in place.
  4. Nipple (C) and Tooth Washer (D): Use the nipple and tooth washer to connect different parts of the fixture together.
  5. Canopy (J): Attach the canopy to cover the electrical connections.
  6. Chain (K): Adjust the length of the chain according to your preference and attach it to the fixture.
  7. Ground Screw (F): Connect the ground wire to the mounting plate. Never connect the ground wire to the hot wire.
  8. SPT Wire: Connect the wires according to their markings. Never reverse the hot and neutral wires.
  9. Bulb (M) and Socket: Install an 8-watt LED, Type G lamp into the socket. Do not exceed the recommended wattage.

Replacement Parts

  • Hardware Kit: HDW-56
  • Canopy: 56CPY
  • Chain: 56CHN
  • Safety Cable: 56CBL

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.

  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
    MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.

  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM.
    WASH HANDS AFTER USE.

  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.

  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

FIXTURE INSTALLATION

  1. Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.

  2. Attach the SAFETY CABLE (N) to the building structure or brace using CABLE CLIP (0).

  3. Remove the SCREW COLLAR (I) from the COLLAR LOOP (H). Fully thread the NIPPLE (C) onto the COLLAR LOOP (H). Thread the HEX NUT (E) onto the NIPPLE (C) along with TOOTH WASHER (D).
    Then thread the NIPPLE (C) unto the MOUNTING PLATE (A). Adjust the NIPPLE (C) so that the threads of the COLLAR LOOP (H) extends |* beyond the CANOPY (I). Secure using HEX NUT (E).

  4. Open the end link the of the CHAIN (K) and attach to the FIXTURE ASSEMBLY (L) at the desired height.
    Slide the SCREW COLLAR (1) and the CANOPY (I) onto the CHAIN (K). Open the link on other end of the CHAIN (K) then attach unto the COLLAR LOOP (H). Feed the wires through the CHAIN (K), SCREW COLLAR (1), CANOPY (J), COLLAR LOOP (H), NIPPLE (C), and MOUNTING PLATE (A).

  5. Cut off excess wires, and strip the insulation off the end of the leads.

  6. Attach the Ground wire to the ground inside the junction box (Generally green or bare copper wire) or the GROUND SCREW (F) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO ‘HOT’ WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!

  7. Connect the fixture’s SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (G). Starting 1* below the fastener, fightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!

  8. Connect the fixture’s SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!

  9. Push the wires back into the junction box. Lift up the CANOPY (1) up to the ceiling, and screw the SCREW COLLAR (I) onto the COLLAR LOOP (H).

  10. Screw the BULB (M) into the SOCKET of the FIXTURE ASSEMBLY (L). THIS FIXTURE IS RATED FOR8 WATT LED, TYPE G LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!

  11. Restore power to the outlet at the breaker or fuse box.

CORBETT 356-49-VGL Aimi 12 Light Chandelier-fig1

PART(S) REPLACEMENT PART NAME NUMBER
A,B,C,D,E,F,G,H,I HARDWARE KIT HDW-356-49
J CANOPY CPY-356-49
K CHAIN CHN-356-21
N,O SAFETY CABLE CBL-356-32

www.hvlgroup.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CORBETT User Manuals

Related Manuals