SANUVOX P900 Portable UV Air Purifier Instruction Manual

June 13, 2024
SANUVOX

SANUVOX-LOGO

SANUVOX P900 Portable UV Air Purifier

Product Information

Product Name: P900 Portable UV Air Purifier
Model: Residential / Commercial Model
Product Type: UV Air Purifier

Important Safety Instructions

  • Read and follow all instructions contained in the manual before using the product.
  • Read the maintenance instructions before opening the UV unit or system.
  • Never expose eyes or skin to an operating UV lamp.
  • Installation and servicing of UV units or systems can be hazardous. Only trained and qualified service personnel should install, repair or service equipment.
  • Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel.
  • The unit is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge.
  • CAUTION: Unit is not a toy. Keep away from unsupervised children. Do not leave children unattended with the unit.
  • DO NOT hang onto the UV unit or system.
  • Some UV units or systems could be heavy. Make sure you have a minimum of 2 people to safely move or install these UV units or systems, and make sure you adopt the necessary precautions to avoid injuries.
  • CAUTION: Electrical shock may cause injuries or damage to the UV unit or system. Turn off and disconnect the UV unit or system from all power sources before installing or performing maintenance.
  • All UV units or systems contain a UV-C source. Damage to the housing or unintended use of the UV unit or system may result in harmful UV-C leaks. UV-C may cause harm to the eyes and skin.
  • Follow all the safety instructions outlined in this document and respect all local and national codes applicable.
  • Dispose of unit or system according to the specific instructions and standards of your local and national authorities.
  • Sanuvox UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS OR IN WET LOCATION unless specified otherwise.
  • Use only specified SANUVOX branded replacement UV lamps for your UV unit or system. Use of any other lamps will void your warranty and can result in damage to the UV unit or system.

Product Usage Instructions

  1. Before using the UV air purifier, read and understand all the instructions provided in the manual.
  2. Ensure that you have a minimum of 2 people to safely move or install the UV air purifier.
  3. Follow the necessary precautions to avoid injuries while handling the UV air purifier.
  4. Do not hang onto the UV air purifier or system.
  5. If basic maintenance functions such as replacing lamp(s) and/or filter(s) are required, untrained personnel can perform those tasks. However, for any other operations, contact trained service personnel.
  6. Keep the UV air purifier away from unsupervised children and do not leave children unattended with the unit.
  7. Turn off and disconnect the UV air purifier from all power sources before installing or performing any maintenance on the unit.
  8. Avoid exposing your eyes or skin to an operating UV lamp. UV-C emitted by the lamp can cause harm.
  9. Follow all the safety instructions provided in the user manual and comply with local and national codes.
  10. Dispose of the unit or system according to the specific instructions and standards of your local and national authorities.
  11. Do not install the UV air purifier outdoors or in wet locations unless specified otherwise.
  12. Use only specified SANUVOX branded replacement UV lamps for your UV air purifier. Using any other lamps will void your warranty and may result in damage to the unit.

P900
PORTABLE UV AIR PURIFIER
Residential / Commercial Model

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.

  1. Installation and servicing of UV units or systems (in an air conditioning system or not) can be hazardous. Only trained and qualified service personnel should install, repair or service equipment.

  2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel.

  3. The unit is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
    CAUTION: Unit is not a toy. Keep away from unsupervised children. Do not leave children unattended with the unit.

  4. DO NOT hang onto the UV unit or system.

  5. Some UV units or systems could be heavy: Make sure you have a minimum of 2 people to safely move or install these UV units or systems, and make sure you adopt the most ergonomic position possible (use UV unit or system handles, if applicable).
    CAUTION: Installing or maintaining heavy equipment, especially overhead, can cause back pain or other injuries.

  6. When installing or servicing an overhead UV unit or system, be careful not to fall off the stepladder. Furthermore, make sure the UV unit or system latches are always in place to prevent falling parts.
    CAUTION: Some parts of some UV units and systems may open suddenly if the UV unit or system is installed high up without its locks.

  7. Units that are obviously damaged must not be operated.

  8. CAUTION: When working on the UV unit or system, observe precautions on the literature, tags and labels attached to the UV unit or system, and all other safety precautions considered as best practices in the HVAC industry, if applicable.

  9. When applicable, local regulation may comprise more restrictive installation and/or certification requirements.
    The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense.

  10. Follow all the safety instructions outlined in this document and respect all local and national codes applicable.

  11. All UV units or systems contain a UV-C source. Damage to the housing or unintended use of the UV unit or system may result in harmful UV-C leaks. UV-C may, even in little doses, cause harm to the eyes and skin.

  12. Never expose eyes or skin to an operating UV lamp.
    Therefore, before installing or performing maintenance on the UV unit or system, TURN OFF AND DISCONNECT the UV unit or system from all power sources (there may be more than one switch to disconnect) and also disconnect the HVAC system, is applicable.
    CAUTION: Electrical shock may cause injuries or possibly death. FIRST AID INSTRUCTIONS: If injured, consult a doctor.

  13. To reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter the plug in any way.

  14. UV rays may damage certain types of filters (polymer or plastic); please keep the UV unit or system light away from shining directly on plastic.

  15. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves 15. Just like conventional fluorescent lamps, UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use in the same way as any other fluorescent lamps.
    Contact and follow the specific instructions of your local and national authorities.

  16. Dispose of unit or system according to the specific instructions and standards of your local and national authorities.

  17. Use only specified SANUVOX branded replacement UV lamps for your UV unit or system. Use of any other lamps will void your warranty and can result in damage to the UV unit or system.

  18. Sanuvox UV units or systems are not waterproof. DO NOT
    INSTALL OUTDOORS OR IN WET LOCATION unless specified otherwise.

  19. Use of this unit or system supplements, but does not replace, infection control best practices. Users must follow all these practices, particularly with regard to cleaning and disinfecting surfaces.

SAVE THESE INSTRUCTIONS
For any inquiries on a UV unit or system, contact :
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
techsupport@sanuvox.com

ABOUT THE PRODUCT
Congratulations on the purchase of the P900. Sanuvox systems are the most advanced air purification systems available, that can help reduce biological and chemical contaminants that circulate throughout the building. Sanuvox systems have been tested by universities, in hospitals and by independant third party laboratories.

The P900 is designed to purify the air of a small room (up to 900 cubic feet), helping reduce chemical and biological contaminants.
The unit is designed for small homes and apartments, and can be used in commercial areas.
For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869.

COMPONENTS

How it Works
Foul air enters the P900 parallel to the UV ‘J’ lamp, thus increasing contact time with the UV light. First, the air goes through an inlet filter that captures particles. After, the UV lamp attacks biological contaminants. Finally, the purifed air circulates through the home.

  • A. Control Panel Display
  • B. Handle Notch (for wall-mounting)
  • C. UV Lamp Access Door
  • D. Stand

SANUVOX-P900-Portable-UV-Air-Purifier-FIG- \(1\)

SETUP & INSTALLATION

What you will need
A utility knife to unpack all components and a Phillips No.2 screwdriver.

CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack,install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

What’s included
The P900 with its UV lamp and a basic installation kit.

SANUVOX-P900-Portable-UV-Air-Purifier-FIG- \(2\)

The installation kit includes: a UV caution decal, a maintenance decal, a stand, an handle and a screw (1) for the handle.

Step by Step Setup & Installation

SANUVOX-P900-Portable-UV-Air-Purifier-FIG- \(3\)

  1. Prepare the P900 for installation. Remove unit from packaging.
    Before plugging the P900, turn it face down and place on soft surface to protect top.

  2. Install stand or handle.
    See Stand and Handle Installation instructions on page 5.

  3. Replace the P900 upright or on wall and plug the purifier in a wall outlet.
    You are now ready to power ON your new P900 and enjoy great air quality.

Step by Step Stand Installation

  1. Loosen the two bottom screws between the two rubber feet.
  2. Slide the stand through the two screws and tighten.

Step by Step Handle Installation

  1. The handle fits into the wall/ handle notch just under the middle rubber foot. Slide the handle in and screw it in place.

OPERATION

How to Operate your Product
The P900 is an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON and enjoy clean air!

CAUTION: The suggested operating temperature range is 10 to 50°C (50 to 122°F). Operating the P900 outside this range will result in decreased performance. For optimal performance, air temperature moving through the unit should be in the range of 15 to 20°C (60 to 70°F).

How to Read the Control Panel Display
The P900 control panel display will give you real time status update about its fan speed and timer settings.

  • A. Up Arrow Button
  • B. LED Display Window
  • C. Power ON/OFF Button
  • D. Down Arrow Button
  • E. Timer Mode LED Indicator
  • F. Fan Speed LED Indicator
  • G. Mode Button

Default Settings

  • When the unit is plugged, all settings are OFF: push the power button to turn on unit.
  • Default fan speed is set to 3, which is considered the optimum performance.
  • Default run time is set to “C” (continuous operation).
  • The fan is always running when the lamp is on.
  • You can then select the P900 fan speed and operating time at any time to suit your individual preferences.
  • During operation, the LEDs and display toggle every 5 seconds between TIME and FAN setting display, showing time remaining and fan speed.
  • Operation will resume at default time/speed whenever unit is turned off and on again.

How to Switch from Default to Timer Mode

  1. While the P900 is powered ON, press the “Mode Button” to switch between settings. When “Timer Mode LED Indicator” flashes, your unit is on “Timer Mode” settings and the numeric digit on the “LED Display Window” corresponds to the time left before shutting down.

  2. Use the up and down arrow buttons to select run time.
    Run time can be set between 1 to 9 hours or to “C” (Continuous operation).

  3. Wait for a short period without touching any buttons for P900 to register new settings. Your unit will then start working with the timer mode activated.
    After the set time has elapsed, lamp, fan and display will turn off.

How to Adjust Fan Speed
1. While the P900 is powered ON, press the “Mode Button” to switch between settings. When “Fan Speed LED Indicator” flashes, numeric digits on the “LED Display Window” corresponds to the unit fan speed.
2. Use the up and down arrow buttons to select fan speed. Variable fan speeds can be set between 1 to 9.

MAINTENANCE

How to Replace Lamp(s)
Replacing lamp on the P900 is quick and easy. Simply turn off the power source, remove and dispose of old lamp, replace with new Sanuvox branded UV lamp, turn power source back on. See below for detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

Step by Step Lamp Replacement

  1. Unplug P900 from wall outlet.
    Turn face down and place on soft surface to protect top of unit.
    CAUTION: Before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources.

  2. Remove the 4 screws from the lamp access door. Then remove lamp access door.
    NOTE: There is a micro switch / cut-off switch to cut power to the P900 when the lamp access door is removed.

  3. Once the lamp access door is removed hold the old lamp by the ceramic socket and remove the white plug from the old lamp.

  4. Press the lamp clamp to release the old lamp, and slowly remove the old lamp.

  5. Prepare the UV lamp for installation. Remove lamp from packaging.
    Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve.

  6. Press the lamp clamp and insert the new lamp. Release lamp clamp to secure lamp in place.

  7. Holding the ceramic base, attach the plug to the new lamp. The plug will fit in one direction only. It may be necessary to rotate the plug 90° to attach it.

  8. Replace the lamp access door and secure it with its 4 screws.

  9. Replace the P900 upright or on wall and plug the purifier in a wall outlet.

How to Clean your Product

For optimal performance, the lamp(s) and filter(s) should be kept free of dust and residue deposit. Clean when necessary with mild soap or alcohol. To clean the unit exterior, use a damp cloth with general purpose detergent. Always spot test the cleaner to make sure it does not damage the surface.

CAUTION: Under no circumstance should water be sprayed or splashed onto the product.

Step by Step Inlet Filter Cleaning

  1. Detach the two thumbscrews on the top of the filter frame with a non-magnetic 5/16″ nutdriver. Then, remove the filter frame.

  2. Remove the plastic inlet grill.

  3. Remove the aluminum filter and clean it.
    NOTE: The filter can be washed in a mild detergent, soap and water.

  4. When filter is dry, reinstall it on the inlet posts.

  5. Replace the plastic grill.

  6. Replace the filter frame. Reattach the thumbscrews: place them with your finger and tighten them with the nutdriver.

STORAGE
The P900 does not require specific storage. It is a portable unit that works continuously when ON, or automatically when selecting proper settings (fan speed and timer).

CAUTION: Keep away from unsupervised children. This unit is not a toy.

ULTRAVIOLETS
Ultraviolet wavelengths (UV) emitted by Sanuvox units and systems are identical to ultraviolets produced by the sun. UVC damage nucleic acids (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market,Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces.

CAUTION: Never expose eyes or skin to an operating UV lamp. Excessive exposure to ultraviolet radiation is associated with different types of skin cancer, sunburn, accelerated skin aging, as well as cataracts and other eye diseases. The severity of the effect depends on the wavelength, intensity, and duration of exposure.

ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE
The P900 has a power consumption of 33W. The product is rated at 120V to 240V, and 50 Hz to 60 Hz.
See product label to confirm power consumption of your specific unit or system.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY.
DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

TROUBLESHOOTING

If your product is not working properly, refer to the following.

What you will need
A Phillips No. 2 screwdriver, a non-magnetic 5/16″ nutdriver and spare parts.

SANUVOX-P900-Portable-UV-Air-Purifier-FIG- \(15\)

Step by Step Verification of Motor Wire Connection

  1. Unplug P900 from wall outlet.
    Turn face down and place on soft surface to protect top of unit.
    CAUTION: Before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources.

  2. On the back of the P900, unscrew the 8 screws along the sides (4 on the left, and 4 on the right) to open the unit.

  3. Once unscrewed, lift the cover to open the unit.
    Look at the top to see if the motor connection is properly connected.

WARRANTY

You should first read all instructions before attempting to use this product.
For this warranty to be valid, keep a copy of the proof of purchase.

UV lamp 3 years (residential), 2 years (commercial)
Ballast 3 years
Electronic components 3 years
  • This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
    SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
    Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

  • At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

  • This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

  • This warranty does not cover the filters, pre-filters or other accessories (if included), except for material or workmanship defects.

Call us toll-free at 1-888-726-8869 or email: info@sanuvox.com
Please be sure to specify product name.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

CUSTOMER SERVICE
TO ORDER REPLACEMENT PARTS
PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE
Toll-Free Phone #: 1-888-726-8869
Email: info@sanuvox.com
Website: www.sanuvox.com
Please be sure to specify product name.

Replacement parts for this product

BST120/240GL Ballast with input of 120 / 230VAC, 50 / 60Hz
LMPRGJ65 T6 6.5″ UV ‘J’ lamp
FTR-7 Metal inlet filter
FTR-8 Inlet grill
ELC-MTR-8 Motor assembly

WARNING: Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

www.sanuvox.com
1-888-726-8869

REGISTER YOUR WARRANTY ONLINE AT
www.sanuvox.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals