SANUVOX BIOSMART Touch Screen For Bio-Wall Instruction Manual

June 13, 2024
SANUVOX

SANUVOX - logo BIOSMART Touch Screen For Bio-Wall
Instruction Manual

BIOSMART Touch Screen For Bio-Wall

SANUVOX BIOSMART Touch Screen For Bio Wall - qr code

BIOSMART SCREEN
TOUCH SCREEN FOR BIO-WALL™
Commercial Model

IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.

NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.

  1. Installation and servicing of UV units or systems (in an air conditioning system or not) can be hazardous. Only trained and qualified service personnel should install, repair or service equipment.

  2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel.

  3. The unit is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
    CAUTION: Unit is not a toy. Keep away from unsupervised children. Do not leave children unattended with the unit.

  4. DO NOT hang onto the UV unit or system.

  5. Some UV units or systems could be heavy: Make sure you have a minimum of 2 people to safely move or install these UV units or systems, and make sure you adopt the most ergonomic position possible (use  UV unit or system handles, if applicable).
    CAUTION: Installing or maintaining heavy equipment, especially overhead, can cause back pain or other injuries.

  6. When installing or servicing an overhead UV unit or system, be careful not to fall off the stepladder. Furthermore, make sure the UV unit or system latches are always in place to prevent falling parts.
    CAUTION: Some parts of some UV units and systems may open suddenly if the UV unit or system is installed high up without its locks.
    6.1.THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE HOT-AIR SIDE OF DUCT-TYPE SYSTEMS.

  7. Units that are obviously damaged must not be operated.

  8. CAUTION: When working on the UV unit or system, observe precautions on the literature, tags and labels attached to the UV unit or system, and all other safety precautions considered as best practices in the  HVAC industry, if applicable.

  9. When applicable, local regulation may comprise more restrictive installation and/or certification requirements.
    The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense.

  10.  Follow all the safety instructions outlined in this document and respect all local and national codes applicable.

  11. All UV units or systems contain a UV-C source. Damage to the housing or unintended use of the UV unit or system may result in harmful UV-C leaks. UV-C may, even in little doses, cause harm to the eyes and skin.

  12. Never expose eyes or skin to an operating UV lamp. Therefore, before installing or performing maintenance on the UV unit or system, TURN OFF AND DISCONNECT the UV unit or system from all power  sources (there may be more than one switch to disconnect) and also disconnect the HVAC system, is applicable.
    CAUTION: Electrical shock may cause injuries or possibly death. FIRST AID INSTRUCTIONS: If injured, consult a doctor.

  13. UV rays may damage certain types of filters (polymer or plastic); please keep the UV unit or system light away from shining directly on plastic.

  14. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

  15. Just like conventional fluorescent lamps, UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use in the same way as any  other fluorescent lamps. Contact and follow the specific instructions of your local and national authorities.
    15.1. Dispose of unit or system according to the specific instructions and standards of your local and national authorities.

  16. Use only specified SANUVOX branded replacement UV lamps for your UV unit or system. Use of any other lamps will void your warranty and can result in damage to the UV unit or system.

  17. Senufo UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS OR IN WET LOCATION unless specified otherwise.

  18. Use of this unit or system supplements, but does not replace, infection control best practices. Users must follow all these practices, particularly with regard to cleaning and disinfecting surfaces.

SAVE THESE INSTRUCTIONS

ABOUT THE PRODUCT

Congratulations on your purchase of the Senufo BioSmart Screen. The BioSmart Screen has been specially designed for use with the BIO-WALL™ UV system.
This option will greatly improve your experience and the reading of information from your Sanuvox BIO-WALL™ system.
Additional functions provided by the display include remote validation of the status of the unit (lamps and ballast) as well as the hours of use of lamps while allowing you to reset the hour counters of each of the  lamps remotely .
Designed and assembled in Montreal, Quebec, Senufo products are meticulously manufactured with the aim of bringing you the best performance on the market and unparalleled air quality.
For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869.

SETUP & INSTALLATION

What you will need
A knife to unpack all the components, a drill with bits, a screwdriver, anchors and suitable screws.
CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Confirm you have access to the necessary power source for the  product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.
What’s included
The BioSmart Screen, a 5 VDC power supply module, a 20′ Ethernet cable and a grommet.SANUVOX BIOSMART Touch Screen For Bio Wall -
included

Setup
When selecting the appropriate location for your BioSmart Screen, ensure that it can be supplied with the necessary current (100-240V @ 50-60Hz). The 5 VDC power supply must be plugged into a conventional  power outlet.
It is always possible for you to obtain (at your expense) an Ethernet cable longer than 6m if necessary. We recommend a cable with a maximum length of 30m.
The location of the screen should preferably be in an accessible place, on a wall and at eye level.
CAUTION: Make sure the unit is plugged in and powered at the correct voltage. Be sure to leave enough space for service and maintenance.

Step by Step Installation

SANUVOX BIOSMART Touch Screen For Bio Wall - included

  1. Separate the front of the case from the back. Set aside the front of the case that contains the screen.

  2. Depending on the type of surface, please use the appropriate anchors and screws to secure the box to the wall.SANUVOX BIOSMART Touch Screen For Bio Wall - Step1

  3. Aligning the guide grooves on the top of the case, gently push the cover to assemble the two parts of the case.

  4. Prepare to connect the Ethernet cable to the ballast box.
    NOTE: Make sure the power to the ballast box is turned off before following the next steps.SANUVOX BIOSMART Touch Screen For Bio Wall -
Step2

  5. Remove the ballast box cover.

  6. Drill the pre-cut opening of the ballast box housing at the desired location and pass the Ethernet cable through it to then connect it to the Ethernet port of the PCB module.

  7. Then insert the grommet eyelet and fix it around the opening of the ballast box where you passed the Ethernet cable to seal the opening.SANUVOX BIOSMART Touch Screen For Bio Wall - Step3

  8. Connect the Ethernet cable and the power module to the BioSmart Screen.

  9. Connect the other end of the Ethernet cable to the Ethernet port on the display.

  10. Finally, plug the power supply into a conventional power outlet, plugging the DC cable into the BioSmart Screen’s power port.
    Your BioSmart Screen is now ready to operate.

OPERATION

How to Operate your Product

The BioSmart Screen is designed to give you real-time information about the status of the lamps in your BIO-WALL™.

CAUTION: The recommended operating temperature is between 4 to 40°C (40 to 105°F). Using the BioSmart Screen outside of this temperature range may reduce its performance. Touch the touch screen to access the lamp menu.

Different menu icons

| The lamp is on.
---|---
| The lamp has been in operation and has been operating for over 2 years. The lamp should be replaced with a new one.
| The lamp does not work. This or the ballast needs to be replaced.
| The two fans located in the ballast box are stopped. Fans may be clogged with debris or need replacing.
| Exit and return to the previous menu.
| Settings, select the language (French or English).
| Reset the lamp after replacing the old one with a new one.

Lamp Menu
The lamps menu shows you the status of the lamps through an icon for each of the lamps as well as gives you the operation time of the lamps since their commissioning. By pressing directly on the icon of a lamp, you directly access the menu of this lamp.

Lamp Settings Menu
This menu gives you very precise information on the lamp in question, such as the part number, the number it represents in the set of 5 lamps and its operational status. Once you replace a lamp, you can reset the counter to zero.

Admin Menu
From the lamp settings menu, you can access the admin menu by tapping the bottom left screen, then tapping the bottom right screen. In the administrator mode, you can change the lamp type, its length and the type of lamp.

MAINTENANCE

How to Clean your Product
Use a damp cloth with a mild soap or alcohol solution to clean the outside of the screen. Always test the cleaner on a small area before applying to the full surface to be cleaned.
CAUTION: Under no circumstance should water be sprayed or splashed onto the product.

STORAGE
The BioSmart Screen does not require specific storage. It is a permanent unit that works continuously when powered.
CAUTION: Keep away from unsupervised children. This unit is not a toy.
ULTRAVIOLETS
Ultraviolet wavelengths (UV) emitted by Senufo units and systems are identical to ultraviolet produced by the sun. UVC damage nucleic acids (DNA/RNA) of microorganisms, which inactivates them. Unlike  conventional UV lamps on the market, Senufo units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces.
CAUTION: Never expose eyes or skin to an operating UV lamp.
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE
The BioSmart Screen has a power consumption of 4 W.
The BioSmart Screen necessary voltage requirements is 5 VDC.
See product label to confirm power consumption of your specific unit or system.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY.
DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

TROUBLESHOOTING

If your product is not working properly, refer to the following.
What you will need
A Phillips No. 2 screwdriver.

Problem Possible Cause Solution
The screen does not turn on. – The power supply is incorrectly connected or
defective. – Test in another outlet.
Screen shows “SD Card Unmounted”. – SD card is defective. – Replace SD card.

WARRANTY
You should first read all instructions before attempting to use this product.
For this warranty to be valid, keep a copy of the proof of purchase.
BioSmart Screen 1 year

A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty last, so the above limitations or exclusions may not apply to you. This  warranty gives specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of  purchase.
B. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. This warranty does not cover the filters, pre-filters or other accessories (if included), except for material or workmanship defects.
Call us toll-free at 1-888-726-8869 or email: info@sanuvox.com
Please be sure to specify product name.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO  NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

CUSTOMER SERVICE

TO ORDER REPLACEMENT PARTS
PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE
Toll-Free Phone #: 1-888-726-8869
Email: info@sanuvox.com
Website: www.sanuvox.com
Please be sure to specify product name.
Replacement parts for this product
BIOSCREEN BioSmart touch screen for BIO-WALL™
WARNING: Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

REGISTER YOUR WARRANTYhttps://qrco.de/bbnR2e
For any inquiries on a UV unit or system, contact :
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
techsupport@sanuvox.comwww.sanuvox.com
1-888-726-8869

References