General information
JAMARA e.K. is not liable for any damage caused to the product itself or through this, provided this is due to improper operation or handling errors. The Customer alone bears the full responsibility for the proper use and handling, including without limitation, the assembly, the charging process, the use and choice of the operation area. Please refer to the operating and user instructions, it contains important information and warnings.
Certificate of Conformity
**** Hereby JAMARA e.K. declares that the product „LiPo 20 Charger 2S/3S, No.
413117“ complies with Directive 2014/30/EU, 2014/35/EU and 2011/65/EU.
The full text of the EU Declaration of Conformity is available at the
following Internet address: www.jamara-shop.com/Conformity
Read the complete instructions and security instructions carefully before
using the model.
Caution! Please fully and carefully read warnings/ safety instructions. These
are for our own security and can avoid accidents/injuries.
Technical data:
Input:| AC 100 – 240V | 50/60Hz | 25W
---|---
Output:| 8,4 V (2S 7,4 V) / 12,6 V (3S 11,1 V)
Battery types/Cells| LiPo / 2S 7,4 V; 3S 11,1 V
Charging current:| 1,6 A | 20 W
Highlights:
- Integrated charge balancer for 2 to 3 lipo cells
- Maximum safety (does not charge deeply discharged cells)
- Charging current up to 20 Watt at 1.6Ampere
- Automatic charge stop when final charge voltage is reached
- Supports 2S;7.4V and 3S;11.1V lithium polymer batteries with XH connector from 1600mAh
- 2 colored status LED‘s
Important notes on the suitability of the battery:
Make sure to use only lithium polymer batteries with XH balancer connector.
Only these may be used with the charger. Other connections and battery types
must not be used (fire hazard due to reverse polarity or overcharging may
result).
Please contact the manufacturer of your battery to find out whether your
battery is suitable. Only LiPo batteries with a capacity of at least 1600mAh
must be used (otherwise there is a risk of fire due to excessive charging
current). If you use batteries with a capacity below 1600mAh, the batteries
must be approved for a charging current of 1600mA (Speedcharging). Please ask
the manufacturer of your battery if your battery meets these requirements.
You may only connect one single battery to the charger at a time. Charging 2
batteries at the same time is NOT allowed and will cause damage to the battery
or charger (fire hazard).
- Power Slot 100 – 240 V
- 2S Balancer
- 3S Balancer
- Status LEDs
All rights reserved. Copyright JAMARA e.K. 2023
Copying or reproduction in whole or part, only with the expressed permission
of JAMARA e.K.
Charging a battery
- Plug the power cord of the charger into a suitable socket. The LEDS light up green and indicate that the charger is ready for charging.
- Now connect the empty battery to the charger. 7.4V 2S batteries to the 3 pin connector or 11.1V 3S batteries to the 4 pin connector. Do not use force and pay attention to reverse polarity. The LEDs change to red after a few seconds and indicate that the battery cells are charging.
Attention:
When connecting a 2S battery, only the first 2 LEDs (Cell1-2) change to red,
LED 3 (Cell 3) will remain green. When 3S batteries are connected, all LEDs
are red (Cell1-3).
As soon as a the battery cell is full, the corresponding LED changes to green.
Because the cells are charged individually in a balanced way, it is possible
that one cell is fully charged earlier than the others. Always leave the
battery on the charger until all connected cells are fully charged (green) to
allow the charger to balance your battery
Detecting a full battery.
When you connect a full battery to the charger, the LEDs will turn red for a
few seconds and then turn green again. This means that the battery is already
fully charged.
Detecting a defective battery.
If the LEDs remain green when an empty battery is connected, there is a defect
in the battery (cell defect or deep discharge). In this case, immediately
disconnect the battery from the charger and use another battery.
Safety Information
- Charging may only be carried out by adults
- Only for indoor use.
- Never expose the charger to dust, dirt, moisture and direct sun light.
- After use always disconnect the charger from the power source and remove any connected batteries.
- Do not open the charger to do repairs. This will void the guarantee and may be dangerous. If the charger is damaged or faulty, return it to our service department for repairs.
- Follow the instructions of the battery manufacturer.
Disposal restrictions
Electrical appliances must not be disposed of in domestic waste and must be disposed of separately. You are obliged to take out the batteries, if possible, and to dispose of the electrical equipment at the communal collection points. Should personal data be stored on the electrical appliance you must remove them by yourself.
Service centre
Mooser T-Trade, Thomas Mooser, Bürgermeister-Koch-Str. 32a, DE-82178 Puchheim,
Tel +49 (0) 89 17929867,
Fax +49 (0) 89 17929869,
info@mooser-t-trade.de,
www.mooser-t-trade.de
JAMARA e.K.
Inh. Manuel Natterer
Am Lauerbühl 5 – DE-88317 Aichstetten
Tel. +49 (0) 75 65/94 12-0
– Fax +49 (0) 75 65/94 12-23
info@jamara.com
www.jamara.com
Service – Tel. +49 (0) 75 65/94 12-777
service@jamara.com
References
- Naslovnica - Net.hr
- t-trade.de is available for purchase - Sedo.com
- jamara.com
- Janus Trade
- Modellbau Zentral - Peter Hofer - Altdorf UR
- Reitter Modellbau & Robotics - Zubehör, Ersatzteile, Bausätze
- Mooser T-Trade: Dein neuer Lieblings-Online-Shop für Plastik Modellbau
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>