Please follow the steps below to properly use the CTV-1501:

  1. Review the important safety instructions located in the operator’s manual.
  2. Ensure that the outlet hose is connected.
  3. Close the prime valve.
  4. Open the inlet valve.
  5. Close the outlet valve.
  6. Make sure the power switch is in the OFF position.
  7. Connect the inlet hose to the water supply.
  8. Priming the CTV-1501:
    • Turn on the water supply.
    • Submerge the cleaning tool under the surface of the water in the cooling tower basin.
    • Open the prime valve to purge air from the inlet hose.
    • Wait until air bubbles stop.
    • Go back to the machine and turn on the power switch.
    • Partially open the outlet valve.
    • Close the prime valve when a full column of water is flowing.
  9. Begin vacuuming the basin by keeping the cleaning tool under the surface of the water.
  10. If the unit fails to prime, consult the operating and maintenance manual.

Proper Startup Essentials

GOODWAY-CTV-1501-Cooling-Tower-Waterbasin-Vacuum-fig-1

GETTING READY

GOODWAY-CTV-1501-Cooling-Tower-Waterbasin-Vacuum-fig-2

GOODWAY-CTV-1501-Cooling-Tower-Waterbasin-Vacuum-fig-3

PRIMING THE CTV-1501

GOODWAY-CTV-1501-Cooling-Tower-Waterbasin-Vacuum-fig-4

  1. With the water supply turned on, submerge the cleaning tool under the surface of the water in the cooling tower basin.
  2. Open the prime valve to…GOODWAY-CTV-1501-Cooling-Tower-Waterbasin-Vacuum-fig-5
  3. Purge the air from the inlet hose.GOODWAY-CTV-1501-Cooling-Tower-Waterbasin-Vacuum-fig-6
  4. When the air bubbles stop, go back to the machine and turn the power switch on and partially open the outlet valve.
  5. Close the prime valve when a full column of water is flowing. Begin vacuuming the basin, keeping the cleaning tool under the surface of the water. If the unit fails to prime consult the Operating and Maintenance Manual.