HYTRONIK SAM12-TY Dimmable Sensor Module A

Dimmable Sensor Module with

Bluetooth BW 1 Mesh

SAM12/TY

Tuya Enabled

Product Description

SAM12/TY is a Bluetooth sensor head only with 12VDC input and 5V 1kHz PWM / 0-10V output, it ‘s ready to be integrated into a third-party LED driver, no control base needed. It is suitable for bulkhead, tri-proof, LED panel, linear, pendant, high-bay. Meanwhile, all commissioning and settings can be done via smart.

Features

Use Tuya smart for commissioning
  Grouping luminaires via mesh network
5V 1kHz PWM / 0-10V output
Tri-level dimming control based upon occupancy (also know as corridor function)
Robust HF antenna design wireless interference
Device firmware update over-the-air
5-year warranty

Free smartphone App for set-up and commissioning

Technical Specifications

Bluetooth Transceiver

Operation frequency| 2.4 GHz – 2.483 GHz
Transmission power| Max 4dBm
Range (Typical )| 10~30m
Sensor Data
Operation frequency| 5.8 GHz +/- 75MHz
Transmitting power| <0.2mW
Detection range*| Max installation height: 6m
Max detection range (Ø): 12m
Detection angle| 30° ~ 150°
Input & Output Characteristics
Input| 12VDC
Output| 5V 1kHz PWM / 0-10V output
Stand-by power| <0.3W
Environment
Operation temperature| Ta: -20°C ~ +60°C
IP rating| IP20

  • The detection range is heavily influenced by sensor placement (angle) and different walking paces.
    It may be reduced under certain conditions.
Mechanical Structure & Dimensions

HYTRONIK SAM12-TY Dimmable Sensor Module Dimensions 1   HYTRONIK SAM12-TY Dimmable Sensor Module Dimensions
2   HYTRONIK SAM12-TY Dimmable Sensor Module
Dimensions 4

Wiring Diagram

HYTRONIK SAM12-TY Dimmable Sensor Module Dimensions 5

Functions and Features

1 Tri-level Control (Corridor Function)

Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice before switch-off. The sensor offers 3 levels of light: 100%–>dimmed light (natural light is insufficient) –>off; and 2 periods of selectable waiting time: full light duration and microlight duration; Selectable daylight threshold and freedom of detection area.

With sufficient natural light, the light does not switch on when presence is detected.

With insufficient natural light, the sensor switches on the light automatically when presence is detected.

After full light duration, the light dims to micro brightness if the surrounding natural light is below the daylight threshold.

Light switches off automatically after the microlight duration elapses.

Highlight

1 Robust HF Sensors Design – Anti-interference Technology

HYTRONIK SAM12-TY Dimmable Sensor Module C 5 Hytronik’s microwave motion sensor uses 5.8GHz high frequency (HF) antenna in the product design. With the increasing density of wireless environments such as 5G GSM tower and 5G Wi-Fi coverage, this has created extra challenges for sensor’s operation because the air is shared by all kinds of wireless signals, and transmissions from any device at the similar frequency could potentially cause interference. The effects of interference which can be noticed by users are usually false triggering of sensors (turning on/off erratically), or lights staying on even after hold time etc.
To get around such tough environment, Hytronik has developed a new series of robust HF modules, designed to be loaded with our own special sophiscated software algorithms. These robust HF modules can withstand different types of wireless interferences in the real application. We believe this is the ultimate solution towards demanding installation environments in the future.

HYTRONIK Robust HF Sensors Design A

  1. 5G Router
  2. Anti-interference
  3. Hytronik Microwave Sensor (New Robust Antenna)
  4. 5G GSM tower
  5. Other types of wireless sources (such as Bluetooth, RF etc.)

2 Grouping luminaires via mesh network

  1. Grouping the primary tri-proof light with the secondary tri-proof light with APP setting.
  2. When the primary tri-proof light receives Bluetooth signal, it tranmits to the the secondary tri-proof light so the tri-proof lights switch on at the same time.

*All the settings can be finished on the APP.

HYTRONIK Robust HF Sensors Design B

Detection Pattern

HYTRONIK Robust HF Sensors Design D1

Ceiling mounted detection pattern (m)

HYTRONIK Robust HF Sensors Design D2

Wall mounted detection pattern (m)

Additional Information / Documents
  1. Regarding precautions for Bluetooth product installation and operation, please kindly refer to
    www.hytronik.com/download/knowledge ->Bluetooth Products – Precautions for Product Installation and Operation

  2. Data sheet is subject to change without notice. Please always refer to the most recent release on
    www.hytronik.com/products/Bluetooth 5.0 SIG mesh system ->Partnership

  3. Regarding Hytronik standard guarantee policy, please refer to
    www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy


Subject to change without notice.

Edition: 05 Jul. 2022    Ver. Draft

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HYTRONIK User Manuals

Related Manuals