GOODWAY - logo RAM-5 Quick Start GuideGOODWAY RAM-5 Speed Feed
Gun

Proper Startup Essentials

GOODWAY RAM-5 Speed Feed Gun - Startup

  1. Attach the dolly to the base by laying the machine flat and tightening the screws by hand.

  2. Thread the guide tube assembly and the air lines on to the side of the machine. Make sure the drain box is vertical.

  3. The two air lines need to be connected above the shaft outlet. The air line without the tag on the left, the air line with the “Forward” label on the right.
    GOODWAY RAM-5 Speed Feed Gun - Startup 4

  4. Once the machine is plugged in and the GFCI has been reset, walk the gun assembly out so it is not coiled, feed the cable into the side of the machine and out the guide tube assembly by pulling the trigger on the gun. Do this before  the cable has been connected to the manifold and a brush has been attached to the end of the cable.

  5. Insert shaft male coupling into shaft manifold then push shaft nut into locking collar to lock in place.GOODWAY RAM-5 Speed Feed Gun - Startup 6

  6. Attach a water hose to the machine and turn the water supply on.
    GOODWAY RAM-5 Speed Feed Gun - Startup 7

  7. Attach the brush to the shaft by sliding the quick connect coupling towards the cable and placing the brush into the fitting. Measure out the length of cable you will need and tighten the shaft stop (Note: brush should extend out the  back of the HEX tube only as far as the brush stem). Refer to manual for proper length.

GOODWAY - logo

HVAC & FACILITY MAINTENANCE SOLUTIONS
GOODWAY® TECHNOLOGIES CORPORATION
420 West Avenue, Stamford, CT 06902 USA
Tel: 203-359-4708 · Toll-Free Tel: 800-243-7932
Fax: 203-359-9601 · Toll-Free Fax: 800-359-9625
Email: goodway@goodway.com
Visit: www.goodway.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals