ABB MO132-32 Manual Motor Starter Magnetic Only User Manual

June 13, 2024
ABB

ABB MO132-32 Manual Motor Starter Magnetic Only

General Information

  • Extended Product Type MO132-32
  • Product ID 1SAM360000R1015
  • EAN 4013614400308
  • Catalog Description MO132-32 Manual Motor Starter Magnetic Only 32 A
  • Long Description
    • The MO132-32 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 32.0 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 30 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switchposition indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3- phase bus bars, power in-feed blocks are available as accessory.

Ordering

  • Minimum Order Quantity 1 piece
  • Customs Tariff Number 85362010

Popular Downloads

  • Data Sheet, Technical 2CDC131035D0202
  • Information Instructions and 2CDC131034M6801 Manuals
  • Instructions and 2CDC131060M0202  Manuals (Part 2)
  • Time-Current 1SAM300515F0008
  • Characteristic Curve 1SAM300507F0001 1SAM300507F0003
  • I²t Characteristic 1SAM300508F0001 1SAM300508F0003
  • Cut-off Current Characteristic
  • CAD Dimensional Drawing 2CDC001079B0201
  • Dimension Diagram 1SAM300402F0002

Dimensions

  • Product Net Width 45 mm
  • Product Net Height 97.8 mm
  • Product Net Depth / Length 86.55 mm
  • Product Net Weight 0.31 kg

Technical

  • Rated Service Short- (230 V AC) 30 kA
  • Circuit Breaking (400 V AC) 30 kA
  • Capacity (Ics)
    • (440 V AC) 30 kA
    • (500 V AC) 10 kA
    • (690 V AC) 3 kA
  • Rated Ultimate Short- (230 V AC) 50 kA
  • Circuit Breaking (400 V AC) 50 kA
  • Capacity (Icu)
    • (440 V AC) 30 kA
    • (500 V AC) 10 kA
    • (690 V AC) 3 kA
  • Rated Instantaneous  Short-Circuit Current Setting (Ii) 400 A
  • Setting Range None
  • Rated Operational Power (400 V) Three Phase 15 kW
  • Rated Operational Power (400 V) Three Phase 15 kW
  • Rated Operational voltage Main Circuit 690 V AC
  • Rated Operational 32 A Current (Ie)
  • Rated Operational 32 A
  • Rated Operational 32 A
  • Rated Frequency (f)
    • Main Circuit 50 Hz
    • Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp) Main Circuit 6 kV
  • Rated Insulation Voltage 690 V
  • Power Loss at Rated Operating Conditions per Pole 3.1 W
  • Number of Poles 3
  • Conventional Free-air Thermal Current (Ith) Main Circuit 32 A
  • Degree of Protection Housing IP20 Main Circuit Terminals IP10
  • Pollution Degree 3
  • Electrical Durability 50000 cycle
  • Mechanical Durability 100000 cycle
  • Terminal Type Screw Terminals
  • Connecting Capacity Main Circuit
    • Flexible with Ferrule 1/2x 0.75 … 6 mm²
    • Flexible with Insulated Ferrule 1/2x 0.75 … 6 mm²
    • Flexible 1/2x 1 … 2.5 mm²
    • Flexible 1/2x 2.5 … 6 mm²
    • Rigid 1/2x 1 … 2.5 mm²
    • Rigid 1/2x 2.5 … 6 mm²
  • Tightening Torque Main Circuit 2 N·m
  • Wire Stripping Length Main Circuit 10 mm
  • Recommended Screw driver Pozidriv 2
  • Mounting Position 1 … 6
  • Mounting on DIN Rail
    • TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    • TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Minimum Mounting Distance
    • Electrical Conductive Board, Horizontal – Up to 400 V 0 mm
    • Electrical Conductive Board, Horizontal – Up to 690 V 1.5 mm
    • Electrical Conductive Board, Vertical 75 mm
    • Other Device Same Type, Horizontal 0 mm
    • Other Device Same Type, Vertical 150 mm
  • Actuator Type Rotary Handle
  • Contact Position ON / OFF / TRIP
  • Standards
    • IEC/EN 60947-1
    • IEC/EN 60947-2
    • IEC/EN 60947-4-1
    • UL 60947-1
    • UL 60947-4-1
  • Remarks For overload protection of the motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA

ABB MO132-32 Manual Motor Starter Magnetic Only 1 ABB MO132-32 Manual Motor Starter Magnetic Only 2

Environmental

ABB MO132-32 Manual Motor Starter Magnetic Only 3

Certificates and Declarations
ABB MO132-32 Manual Motor Starter Magnetic Only 4

Container Information
ABB MO132-32 Manual Motor Starter Magnetic Only 5 ABB MO132-32 Manual Motor Starter Magnetic Only 6

Classifications
ABB MO132-32 Manual Motor Starter Magnetic Only 7

Accessories

ABB MO132-32 Manual Motor Starter Magnetic Only 8 ABB MO132-32 Manual Motor Starter Magnetic Only 9 ABB MO132-32 Manual Motor Starter Magnetic Only 10

Categories

  • Low Voltage Products and Systems → Circuit Breakers → Manual Motor Starters
  • Low Voltage Products and Systems → Control Products → Manual Motor Starters → Manual Motor Starters

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>