Motif™ Risplendi 250 – Rev. A
© 2023 Blizzard Lighting, LLC

GETTING STARTED

What’s In The Box?

  • Motif™ Risplendi 250
  • Power cable
  • 4x interchangeable lenses
  • This user manual

Optional Accessories (sold separately)
The Motif™ Risplendi 250 allows for an optional full snoot accessory which can enhance the light’s output control by concentrating its beam spread. Contact your authorized Blizzard Lighting dealer for pricing.

  • Black Housing: SNOOT-Motif Risplendi (B)
  • White Housing: SNOOT-Motif Risplendi (W)
  • Space Gray Housing: SNOOT-Motif Risplendi (SG)

Getting It Out Of the Box
Congratulations on purchasing the Motif™ Risplendi 250. Now that you’ve got your fixture, you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition. If anything looks as if it has been damaged in transit, notify the shipper immediately and keep the packing material for inspection. Again, please save the carton and all packing materials. If a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Powering Up!
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
Warning! All fixtures must be connected to circuits with a suitable Ground (Earthing).
Getting A Hold Of Us
If something happens to go wrong, visit blizzardpro.com/support and open a support ticket. We’ll be happy to help, honest.
Disclaimer: The information contained in this document are subject to change without notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions that may appear in this user manual. We reserve the right to update the existing, or create a new document to correct any errors or omissions at any time. You can download the latest version of this document from www.blizzardpro.com.

Author: Date: Last Edited: Date:
J. Thomas 3/20/2023 J. Thomas 6/27/2023

Safety Instructions
Please read these instructions carefully. They include important information about the installation, usage and maintenance of this product.

  • Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide.

  • ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture.

  • This product is intended for indoor use only.

  • To prevent risk of fire or shock, do not expose fixture to rain or moisture.

  • Make sure there are no flammable materials close to the unit while operating.

  • The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.

  • ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type.

  • ALWAYS secure fixture using a safety chain. NEVER carry the fixture by its head. Use its carrying handles.

  • DO NOT operate at ambient temperatures higher than 104°F (40°C).

  • In the event of a serious operating problem, stop using the unit immediately. NEVER try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance
    center.
    Always use the same type spare parts.

  • NEVER connect the device to a dimmer pack.

  • Make sure the power cord is never crimped or damaged.

  • Never disconnect the power cord by pulling or tugging on the cord.

  • Avoid direct eye exposure to the light source while it is on.
    Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please open a support ticket at www.blizzardpro.com/support.

MEET THE MOTIF™ RISPLENDI 250

Main Features

  • Light source: 250W RGBAL COB LED, 100,000 hrs.
  • Built-in color & chase macros via DMX
  • Built-in automated programs via master/slave
  • Color mixing ability in standalone mode
  • 4x light collimating lenses (30°, 45°, 60°, 80°)
  • Convection cooled aluminum housing
  • Dual mounting brackets for positioning flexibility
  • Adjustable LED refresh rates (1200Hz-20KHz)
  • PowerCON® TRUE1™ compatible + hardwire AC connector
  • Emergency power backup connector (42-48V DC, 20W)
  • 5-pin male/female XLR input & output connections

Control

  • Protocol: USITT DMX-512, RDM
  • DMX channels: 5/7/11-channels
  • OLED control menu with 4x touch sensitive buttons
  • Operating modes: DMX512, master/slave, auto

DMX Quick Reference (5-Channel Mode)

Channel What is does…
1 Red Intensity (0 <–> 100%)
2 Green Intensity (0 <–> 100%)
3 Blue Intensity (0 <–> 100%)
4 Amber Intensity (0 <–> 100%)
5 Lime Intensity (0 <–> 100%)

DMX Quick Reference (7-Channel Mode)

Channel What is does…
1 Master Dimmer (0 <–> 100%)
2 Red Intensity (0 <–> 100%)
3 Green Intensity (0 <–> 100%)
4 Blue Intensity (0 <–> 100%)
5 Amber Intensity (0 <–> 100%)
6 Lime Intensity (0 <–> 100%)
7 Strobe (Slow <–> Fast)

DMX Quick Reference (11-Channel Mode)

Channel What is does…
1 Master Dimmer (0 <–> 100%)
2 Red Intensity (0 <–> 100%)
3 Green Intensity (0 <–> 100%)
4 Blue Intensity (0 <–> 100%)
5 Amber Intensity (0 <–> 100%)
6 Lime Intensity (0 <–> 100%)
7 Strobe (Slow <–> Fast)
8 Built-In Programs
9 Auto Speed (Slow <–> Fast)
10 Virtual Color Wheel
11 32-Bit Dimming

Motif™ Risplendi 250 Pin-Up Pictureblizzard MOTIF-RISPLENDI-250 Motif
Risplendi 250 - Risplendi

The Rear Connectionsblizzard MOTIF-RISPLENDI-250 Motif Risplendi 250 -
The Rear Connections

 SETUP

Before replacing the fuse, disconnect the power cord.
ALWAYS replace it with the same type and rating.
Fuse Replacement
Remove the fuse holder from of its housing. Take out the damaged fuse from its holder and replace with exact same type of fuse.
Power Inputs
This fixture comes with a powerCON® TRUE1™ compatible power input and a 3-wire power terminal block connector located under the “Int. Power In” cover plate on the rear of the fixture that can be used for hardwiring power.
Depending on which method you use, adjust the external/internal power switch on the back of the unit to select the proper input source.
Use the table below for reference when using the bare wire:

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow or Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green

Connecting the Fixtures
Fixtures on a serial data link must be daisy chained in one single line. Also, connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the signal.
Data/DMX Cabling
To link fixtures together you’ll need data cables. You should use data-grade cables that can carry a high quality signal.
The data cable should have the following characteristics:

  • 2-conductor twisted pair plus a shield
  • Maximum capacitance between conductors – 30 pF/ft.
  • Maximum capacitance between conductor & shield – 55 pF/ft.
  • Maximum resistance of 20 ohms / 1000 ft.
  • Nominal impedance 100 – 140 ohms

Cable Connectors
Cables must have a male XLR connector on one end and a female XLR connector on the other end. (Duh!)blizzard MOTIF-RISPLENDI-250 Motif Risplendi 250 -
INPUT

A Word on Termination: DMX is a resilient communication protocol, however errors still occasionally occur. Termination reduces signal errors, and therefore best practices include use of a terminator in all circumstances. If you are experiencing problems with erratic fixture behavior, especially over long signal cable runs, a terminator may help improve performance.
To build your own DMX Terminator:
Obtain a 120-ohm, 1/4-watt resistor, and wire it between pins 2 & 3 of the last fixture. They are also readily available from specialty retailers.
CAUTION: Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
3-Pin??? 5-Pin??? Huh?!?
If you use a controller with a 3-pin DMX output connector, you will need to use a 3-pin to 5-pin adapter. If you’d like to build your own, the chart below details a proper cable conversion:

Conductor 3-Pin Female (Output) 5-Pin Male (Input)
Ground/Shield Pin 1 Pin 1
Data 1- (Primary Data) Pin 2 Pin 2
Data 1+ (Primary Data) Pin 3 Pin 3
Data 2- (Optional) Pin 4 – Do Not Use
Data 2+ (Optional) Pin 5 – Do Not Use

Take It To The Next Level: Setting Up DMX Control
Step 1: Connect the male connector of the DMX cable to the female connector (output) on the controller.
Step 2: Connect the female connector of the DMX cable to the first fixture’s male connector (input).
Note: It doesn’t matter which fixture address is the first one connected. We recommend connecting the fixtures in terms of their proximity to the controller, rather than connecting the lowest fixture number first, and so on.
Step 3: Connect other fixtures in the chain from output to input as above. Place a DMX terminator on the output of the final fixture to ensure best communication.

Changing the Lenses
This fixture comes with a pre-installed 80° diffuser lens plus 3x replaceable Fresnel lenses (30°, 45°, and 60°) for a variety of beam angles.
To change the lens, remove the thumbscrew from the lens holder and swivel the holder outwards. Replace the existing lens with the lens of your choice.
Note: The replaceable lenses need to be installed with the circular pattern side of the lens facing outwards.
*When using lenses with narrower beam angles, some chromatic aberration (color separation) may occur. We recommend using the snoot accessory (sold separately) to cut off the beam edge. This may help in certain circumstances.blizzard MOTIF-RISPLENDI-250 Motif Risplendi 250 - narrower

Installing or Removing Brackets

  1. Install or remove the brackets as shown above using the included bolts, washers, and knobs.
  2.  Use the small bracket for vertically mounted fixed installations. You can remove the large bracket in these types of applications, and use the included plastic plugs to cover the bracket screw holes.

Mounting & Rigging
This fixture may be mounted in any SAFE position pro- vided there is enough room for ventilation.
Mount the fixture using a suitable “C” or “O” type clamp.
The clamp should be rated to hold at least 10x the fixture’s weight to ensure structural stability. Do not mount to surfaces of unknown strength, ensure properly rated rigging is used, and always secure your fixtures with a safety cable.

OPERATING ADJUSTMENTS

The Control Panel
All of the features and different modes possible with this fixture are accessed by using the control panel on the front of the fixture. There are 4 control buttons next to the menu display which allow you to navigate through the various control panel menus.
< MENU>
Is used to navigate to the previous higher-level menu item.
< ENTER>
Is used to select and confirm/store the current selection.
< UP>
Scrolls through menu items and numbers in ascending order.
< DOWN>
Scrolls through menu items and numbers in descending order.

The control panel display shows the menu items you select from the menu map on page #11. When a menu function is selected, the display will show immediately the first available option for the selected menu function.  To select a menu item, press .
Use the and buttons to navigate the menu options. Press the

button to select the menu function currently displayed, or to enable a menu option. To return to the previous option or menu without changing the value, press the button. **Control Panel Menu Structure**
ADDR 001-512 To choose the DMX address
STAT R Red intensity (0% <–> 100%)
G Green intensity (0% <–> 100%)
B Blue intensity (0% <–> 100%)
A Amber intensity (0% <–> 100%)
L Lime intensity (0% <–> 100%)
SHUT Flash / strobe speed (0-255)
PRSC (preset colors) NONE, R, G, B, A, L, RGBAL, YELLOW, PINK, CYAN, ORANGE,

VIO- LET, GOLDEN, 2700K, 3200K, 4000K, 5500K, 6500K, RGBL
SET| CAL| To set global intensity levels of each color + USE: YES/NO
CHMD| 11CH| To run in 11-channel mode
7CH| To run in 7-channel mode
5CH| To run in 5-channel mode
DIM

(dimming)

| LIN| Linear dimming curve
SQR| Square law curve
ISQR| Inverse square law curve
SCUR| S-curve
LIN.| Linear dimming curve (smooth)
SQR.| Square law curve (smooth)
ISQR.| Inverse square law curve (smooth)
SCUR.| S-curve (smooth)
PWM| < ENTER>| 1200Hz, 2400Hz, 4000Hz, 12000Hz, 16000Hz, 20000Hz
DISY| ON| Menu display is on continually
2OFF| Menu display shuts off after 2 minutes of inactivity
Rotate| Normal| Normal
Rotate| Rotate the display 180°
Intensity| < ENTER>| Adjust the menu brightness level 1-100
CTST| CT01-CT10| < ENTER>| R/G/B/A/L adjustments for custom color banks 01-10
AUTO| AT01-AT05| < ENTER>| Auto programs 1-5
ATSP| < ENTER>| Auto Speed
CHS1| < ENTER>| Custom program 1
CHS2| < ENTER>| Custom program 2
CHS3| < ENTER>| Custom program 3
PROG| CHS1-CHS3

Custom programs 1-3.

| SC01-SC25

25 scenes for each custom program.

| R (0-255)| SHUT (strobe, 0-255)
G (0-255)| AUTO (None, AT01-AT05)
B (0-255)| ATSP (speed, 0-255)
A (0-255)| TIME (duration, 0-255)
L (0-255)| WAIT (before fade, 0-255)
USE (use scene, YES/NO)
INFO| SOFT| Vx.x| Software version information
POWER| < ENTER>| Current automated overheat protection level (100%/80%/50%)
TEMP| < ENTER>| Internal temperature in Celsius
RDM U| < ENTER>| RDM Unique ID (UID)
LOAD| ST L| < ENTER>| Restore factory settings
PR L| < ENTER>| Restore factory program settings
SEND| YES/NO| Sync settings between fixtures via DMX

DMX Mode
Allows the unit to be controlled by any universal DMX controller.
Setting the DMX Address:

  1. The default mode for the fixture is DMX, which appears as 001 on the LED readout. To select a different DMX address, using the button, select ADDR, then hit . Use the <UP/DOWN> buttons to select the correct address, then hit to confirm.

Setting the DMX Channel Mode:

  1.  To select a DMX channel mode, press the button, then use the <UP/DOWN> buttons until the display reads SET and press the button. Then use the <UP/ DOWN> buttons until the display reaches CHMD, and press . Now press the <UP/ DOWN> buttons again to highlight your desired DMX channel mode, and press the button to confirm.

Slave Mode:

  1. Daisy chain the DMX in/out connections on all fixtures.
  2.  There is nothing else to it! The first fixture in the DMX chain is the master fixture, and the other fixtures down the line will follow it.
    Dimming Mode Settings
    Allows users to set the fixture to use 1 of 4 (x2) dimming curve settings for smoother (and slower) dimming capabilities. In the control panel menu, there are two settings for each curve that are distinguishable from one another by the trailing dot.

blizzard MOTIF-RISPLENDI-250 Motif Risplendi 250 - control
panel

*The curve settings with the trailing dot adds a bit more delay to the curve for a smoother effect.

  1. Use the and <UP/DOWN> buttons to navigate to SET and press , then <UP/DOWN> buttons again to scroll to DIM, and press the button.
  2. Now use the <UP/DOWN> buttons to highlight either LIN (Linear), SQR (Square), ISQR (Inverse Square), SCUR (S-Curve), LIN. (Smooth Linear), SQR. (Smooth Square), ISQR. (Smooth Inverse Square), or SCUR. (Smooth S-Curve), then hit .

Custom Programs
Allows users to create up to 3 customizable, 25 scene programs that are directly accessible via the control panel and also in DMX mode.
Creating A Custom Program:

  1. Use the and <UP/DOWN> buttons to navigate to PROG, and press .
  2. Now use the <UP/DOWN> buttons to highlight your choice of either CHS1, CHS2, or CHS3 and press .
  3. Start with editing scene 1 (SC01), customizing it to your liking by using the choices outlined in the table below. You can insert any of its 5 built-in auto programs (AT01-AT05), and adjust its speed (ATSP 0-255), and also set the duration (in seconds) before moving on to the next scene (TIME 0-255). You can also add a fade in effect to the start of this scene (WAIT 0-255), and/or strobe (SHUT 0-255). Finally, if you want to use this scene in your program, be sure to enable it (USE: YES/NO).
  4.  Repeat the above process to create up to 25 scenes in each of the 3 customizable programs.

R (0-255) – Red Intensity| SHUT (0-255) – Strobe (slow – fast)| USE (YES/NO) Use Scene in Program?
---|---|---
G (0-255) – Green Intensity| AUTO (AT01-AT05) – Auto Programs|

_ _IMPORTANT:__ If USE is set to NO, or TIME is set to 0, the scene will not run!

B (0-255) – Blue Intensity| ATSP (0-255) – Auto Speed (fast – slow)
A (0-255) – Amber Intensity| TIME (0-255) – Scene Time (seconds)
L (0-255) – Lime Intensity| WAIT (0-255) – Fade In (fast – slow)

Running A Custom Program:

  1. To view your newly created lighting masterpiece, use the and <UP/DOWN> buttons to navigate to AUTO, and press .
  2.  Use the <UP/DOWN> buttons to highlight your choice of CHS1, CHS2, or CHS3 and press . These are directly accessible from the built-in program channel in DMX mode.

Auto, Modes, and Auto Speed
Set single or Master/Slaved units to run auto modes at user selectable speeds.
Auto Mode:

  1. Use the and <UP/DOWN> buttons to navigate to navigate to AUTO, and press the button.
  2.  Now use the <UP/DOWN> buttons to highlight any program ranging from AT01-AT05, and press .

Auto Speed:

  1.  Use the and <UP/DOWN> buttons to navigate to AUTO and press , then with the <UP/DOWN> buttons navigate to ATSP, and press the button.
  2.  Make a selection from 0-255, and press to choose a speed (slow <–> fast).

Color Calibration Settings
Allows the user to setup and save 1 customized R/G/B/A/L color balance setting and save it for future use.
This custom setting is global, and it will effect all modes.

  1. Use the and <UP/DOWN> buttons to navigate to SET and press , then on while CAL, push again.
  2. Use the <UP/DOWN> buttons to highlight either R (Red Level), G (Green Level), B (Blue Level), A (Amber Level), or L (Lime Level) then hit .
  3. Now using the <UP/DOWN> buttons, select the maximum level for each color between 000-255 (000=off), and hit to confirm your choice.
  4. You have now just setup and saved a custom global color calibration setting that you can use at you convenience. To use your custom setting now (or later), press the <UP/DOWN> buttons to reach USE, and press . Then choose either YES or NO and press . When you select YES, it enables this custom color calibration globally, and when choosing NO the fixture will continue to use the default color calibration settings. Your customized settings will be saved for later use even after powering off the fixture. It can be altered to your liking at any time. Just remember to return to this setting to either enable or disable it when needed.

Custom Static Colors & Preset Colors
Allows the user to create and save custom static colors for use in standalone or DMX mode.
Static Color Mixing and Preset Mixed Colors
Important: When finished editing and saving a static color, you must return to (and stay on) any one of the editing screens (0-255) to make the effect stay on continually. If you were only to press to save your final edit, you would again be on the static color/effect selection menu, which from here will result in blackout mode after 1 minute.

  1. Use the and <UP/DOWN> buttons to navigate to STAT and press , then <UP/DOWN> buttons to select R/G/B/A/L, and push to confirm your selection. Then in adjust the values (0-255) to your liking and press to save.
  2. In the same manner, you can select SHUT to add a strobe effect.
  3. You can also select and use the <UP/DOWN> buttons to scroll through and quickly use any of the fixtures built-in preset colors.

Mix and Save Custom Colors (1-10)

  1. Use the and <UP/DOWN> buttons to navigate to CTST and press , then <UP/DOWN> buttons to select a color bank from CT01-CT10, and push to confirm your selection.
  2. Now use the <UP/DOWN> buttons to highlight either R (Red Level), G (Green Level), B (Blue Level), A (Amber Level), or L (Lime Level), then hit .
  3. Finally, using the <UP/DOWN> buttons, select the maximum level for each color between 000-255 (000=off), and hit to confirm your choice(s).
  4. These 10 custom colors can be accessed and edited to your liking at any time, and will be saved even after powering off the fixture.
  5.  Your custom colors and programs are also directly accessible from the built-in program channel in DMX mode.

Fixture Reset Functions
Allows users to reset the fixture to factory default settings, without loosing customized settings, or reset the custom programs exclusively.

  1. Use the and <UP/DOWN> buttons to navigate to LOAD and press , then use the <UP/DOWN> buttons to highlight ST L or PR L, and press .
  2.  Use the <UP/DOWN> buttons to highlight either YES or NO, then press .
  3. The ST L reset function will reset all default values with the exception of those in ADDR (address), CTST (10 custom colors), and PROG (custom scenes and programs).
  4.  The PR L reset function will only reset all customized program settings found in the PROG settings (custom scenes and programs).

Data Sync Feature
Users can transfer their custom settings from one fixture to another via DMX.

  1. Disconnect fixtures from any DMX controllers, and link them together via DMX in/out.
  2. On the sending fixture (DMX out), navigate the main menu using the <UP/DOWN> buttons to reach SEND, and press the button.
  3. Select YES, and press the button to begin the transfer.
  4. Information for ADDR (address), or CAL (global intensity) will not be sent.
  5. After the data has been transferred, the receiving fixture will be automatically be reset.

Fixture Information
These are not editable features, they are for informational purposes only.

  1. Use the and <UP/DOWN> buttons to navigate to INFO and press , then use the <UP/DOWN> buttons to highlight SOFT or POW, and press .
  2. The SOFT information simply displays the current software version installed on the fixture, and POW displays the fixtures current power level setting. Under normal conditions, it will be at 100%… but this fixture has built-in overheat protection that may automatically reduce the output level to 80%, or 50% in high temperature situations.

DMX Values In-Depth (5/7/11-Channel Modes)

5CH 7CH 11CH Value What It Does
1 1 000 <–> 255 Dimmer (0% <–> 100%)
1 2 2 000 <–> 255 Red Intensity (0% <–> 100%)
2 3 3 000 <–> 255 Green Intensity (0% <–> 100%)
3 4 4 000 <–> 255 Blue Intensity (0% <–> 100%)
4 5 5 000 <–> 255 Amber Intensity (0% <–> 100%)
5 6 6 000 <–> 255 Lime Intensity (0% <–> 100%)
7 7   Strobe
      000 <–> 005 No strobe
      006 <–> 020 Non-synchronous strobe (slow <–> fast)
      021 <–> 060 Synchronous strobe (slow <–> fast)
      061 <–> 100 Electronic sine wave (slow <–> fast)
      101 <–> 140 Random strobe (slow <–> fast)
      141 <–> 180 Opening pulse (slow <–> fast)
      181 <–> 220 Closing pulse (slow <–> fast)
      221 <–> 255 Electronic square wave (slow <–> fast)
8   Built-In Programs
      000 <–> 005 No Function
      006 <–> 010 Custom color 1 (CT01 in menu settings)
      011 <–> 015 Custom color 2 (CT02 in menu settings)
      016 <–> 020 Custom color 3 (CT03 in menu settings)
      021 <–> 025 Custom color 4 (CT04 in menu settings)
      026 <–> 030 Custom color 5 (CT05 in menu settings)
      031 <–> 035 Custom color 6 (CT06 in menu settings)
      036 <–> 040 Custom color 7 (CT07 in menu settings)
      041 <–> 045 Custom color 8 (CT08 in menu settings)
      046 <–> 050 Custom color 9 (CT09 in menu settings)
      051 <–> 055 Custom color 10 (CT10 in menu settings)
      056 <–> 060 Auto 1
      061 <–> 065 Auto 2
      066 <–> 070 Auto 3
      071 <–> 075 Auto 4
      076 <–> 080 Auto 5
      081 <–> 110 Reserved
      111 <–> 115 Red
      116 <–> 120 Green
      121 <–> 125 Blue
      126 <–> 130 Amber
      131 <–> 135 Lime
      136 <–> 140 RGBAL
      141 <–> 145 Yellow
      146 <–> 150 Pink
      151 <–> 155 Cyan
      156 <–> 160 Orange
      161 <–> 165 Violet
      166 <–> 170 Golden
      171 <–> 175 2700K White
      176 <–> 180 3200K White
      181 <–> 185 4000K White
      186 <–> 190 5500K White
      191 <–> 195 6500K White
      196 <–> 200 RGBL
      201 <–> 220 No Function
      221 <–> 225 Custom program 1 (CH01 in menu settings)
      226 <–> 230 Custom program 2 (CH02 in menu settings)
      231 <–> 235 Custom program 3 (CH03 in menu settings)
      236 <–> 255 No Function

DMX Values In-Depth (5/7/11-Channel Modes), continued

5CH 7CH 11CH Value What It Does
9 000 <–> 255 Auto Speed (slow <–> fast)
10   Virtual Color Wheel
      000 <–> 010 No Function
      011 Blue
      012 <–> 050 Blue (+ green)
      051 Cyan
      052 <–> 090 Cyan (- blue)
      091 Green
      092 <–> 130 Green (+ red)
      131 Yellow
      132 <–> 170 Yellow (- green)
      171 Red
      172 <–> 210 Red (+ blue)
      211 Magenta
      212 <–> 250 Magenta (- red)
      251 <–> 255 Blue
11   Dimming Mode
      000 <–> 010 Default (as set in the LED menu)
      011 <–> 020 Linear curve
      021 <–> 030 Square law curve
      031 <–> 040 Inverse square law curve
      041 <–> 050 S-curve
      051 <–> 060 Linear curve (smooth)
      061 <–> 070 Square law curve (smooth)
      071 <–> 080 Inverse square law curve (smooth)
      081 <–> 090 S-curve (smooth)
      091 <–> 255 Default (as set in the LED menu)

Troubleshooting

Symptom Solution
No Light Output Check power connection and ensure that the fixture is

operating under the correct working mode.
Dim Output| Check the overheat protection level in the menu. If it has been triggered, ensure that the fixture has sufficient ventilation.
Chase Speed Too Fast/Slow| Verify that the speed adjustment settings are correct.
Loss of DMX Control| Check the DMX and the power connections to make sure that they are connected.

Make sure the DMX address setting is correct. Check to see if the channel mode setting is correct.

No Power| Verify that the power cord and circuit are functioning.
Blown Fuse| Check power cords and circuit for damage.
Fixture Not Responding / Responding Errati- cally| Make sure all connectors are seated properly and securely. Use only DMX cables and/or check cables for defects. Install a DMX signal terminator. Reset fixture(s).

APPENDIX

Keeping Your Motif™ Risplendi As Good As New
The fixture you’ve received is a rugged, tough piece of pro lighting equipment, and as long as you take care of it, it will take care of you. That said, you’ll need to take care of it if you want it to operate as designed. You should keep the fixture clean, especially if you are using it in an environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled drinks. Cleaning the optics routinely with a suitable glass cleaner will greatly improve the quality of light output. Keeping the fans free of dust and debris will keep
the fixture running cool and prevent damage from overheating. In transit, keep the fixtures in cases. You wouldn’t throw a prized guitar,  drumset, or other piece of expensive gear into a gear trailer without a case, and similarly, you shouldn’t even think about doing it with your shiny new light fixtures.
Common sense and taking care of your fixtures will be the single biggest thing you can do to keep them running at peak performance and let you worry about designing a great light show, putting on a great concert, or maximizing your client’s satisfaction and “wow factor.” That’s what it’s all about, after all!
Returns (Gasp!)
We’ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back, or sending a unit in for service. But, like any complex piece of equipment designed and built by humans, once in a while, something doesn’t go as planned. If you find yourself with a fixture that isn’t behaving like a good little fixture should, you’ll need to obtain a Return Authorization (RA).
Don’t worry, this is easy. Just visit www.blizzardpro.com/support and open a support ticket, and we’ll issue you an RA. Then, you’ll need to send the unit to us using a trackable, pre-paid freight method. We suggest using USPS Priority or UPS. Make sure you carefully pack the fixture for transit, and whenever possible, use the original box & packing for shipping. When returning your fixture for service, be sure to include the following:

  1. Your contact information (Name, Address, Phone Number, Email address).
  2. The RA# issued to you
  3. A brief description of the problem/symptoms. We will, at our discretion, repair or replace the fixture. Please remember that any shipping damage which occurs in transit to us is the customer’s responsibility, so pack it well!

Shipping Issues
Damage incurred in shipping is the responsibility of the shipper, and must be reported to the carrier immediately upon receipt of the items. Claims must be made within seven (7) days of receipt.Tech Specs!

Tech Specs!

Weight & Dimensions

Width| 7.9″ (200 mm)
Depth| 7.9″ (200 mm)
Height| Fixture: 10.9″ (277 mm), w/short bracket: 13.7″ (347 mm)
Weight| 15 lbs. (6.8 kg)
Power
Operating Voltage| 100-240V, 50/60Hz
Power Consumption| 204W, 1.81A, PF: .98
Fuse| 3A, 250V
Light Source
LED| 250W RGBAL COB LED, 100,000 hours
Optical
Luminous Intensity| Lux/m| 2.5-meters| 5-meters| 7.5-meters
35°| 5,976| 1,822| 815
45°| 5,722| 1,640| 734
60°| 4,296| 1,059| 489
80°| 1,759| 488| 226
Thermal
Max. Operating Temp.| 104 degrees F (40 degrees C) ambient
Control
Protocol| USITT DMX-512, RDM
DMX Channels| 5/7/11-channel DMX modes
Data| 5-pin XLR In/Out
Other Operating Modes| Standalone, Master/Slave, Auto Mode


Warranty

| 2-year limited warranty, does not cover malfunction caused by

damage to LEDs. Visit www.blizzardpro.com/warranty.

DISCLAIMER: The power connector fitted to the fixture and fixture cord are designed for compatibility with products manufactured by Neutrik AG, Neutrik USA and their related entities, however they are not manufactured by, affiliated with or endorsed by Neutrik AG, Neutrik USA, or any related entity. Neutrik® and powerCON® are registered trademarks of Neutrik AG.blizzard
MOTIF-RISPLENDI-250 Motif Risplendi 250 - Neutrikblizzard MOTIF-RISPLENDI-250 Motif Risplendi 250 -