Rubine RCF-NAUSCA54-5B Ceiling Fan User Manual

June 13, 2024
Rubine

RCF-NAUSCA54-5B Ceiling Fan
User ManualRubine RCF NAUSCA54 5B Ceiling Fan

REDEFINE THE WAY OF LIFE
RCF-NAUSCA54 SERIES

RCF-NAUSCA54-5B Ceiling Fan

CEILING FAN

NO PARTS QUANTITY NO PARTS QUANTITY
1 TOP CANOPY X1 7b LED PLATE X1
2 HANGING TUBE CNV RUBBER WHEEL X1 8 LED X1
3 COUPLING COVER xi 9 LAMP COVER xi
4 BOLT AND NUT x2 10 BALANCING KIT X1set
5 FAN MOTOR xi 11 BLADE SCREWS Xi
6 FAN BLADES x5 12 RECEIVER X1
7a BOTTOM COVER xi 13 TRANSMITTER X1

Rubine RCF NAUSCA54 5B Ceiling Fan - Feager

FAN SIZE| VOLTAGE| MAX FAN POWER| MAX LIGHT POWER| MAX SPEED ( RPM)| NETT WEIGHT| GROSS WEIGHT
---|---|---|---|---|---|---
54″| 220-240V / 50Hz| 40W| 24W
( Light model )| 240 ± 10%| 10.5 KG| 11.8 KG
54″| 220-240V / 50Hz| 40W| /| 240 ± 10%| 9.3 KG| 10.3 KG

WARNING
TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE INSTRUCTION MANUAL BEFORE OPERATING THE PRODUCT.

  1. Do not bend the blade during installation, blades balancing or fan cleaning.
  2. To prevent accidents, power switch must be OFF and electrical wiring must be disconnected before ceiling fan installation, dismantling, maintenance or cleaning.
  3. Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning engineers ( ASHRAE ) or the local qualified authorities.
  4. Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden parts.
  5. Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be tightened at all allocated parts.

SAFETY GUIDELINES

  1. Please do not install the ceiling fan at high humidity areas.
  2. Distance between fan blades and ground must be at least 2.5 meter and above.
  3. Do not touch the ceiling fan while it is operating.
  4. For safety purposes, all electrical connections must conform to the national electrical safety codes and earth wire must be installed correctly ( suitable for power supply of 220-240VAC / 50Hz ).
  5. Do not modify the ceiling fan and only use the parts supplied accordingly.
  6. Do not attempt to repair the fan. Always liaise to our authorized service agent if the fan is not functioning well.
  7. This appliance is not intended for use by persons ( including children) with lack of sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the  appliance by a person responsible for their safety.
  8. Children should be supervised to ensure that they do not play with the appliance.
  9.  The ceiling fan electrical wiring must be installed with means for disconnection incorporated in the fixed wiring provided and safety cable must be installed according to the steps in this manual.

INSTALLATION PROCEDURES

STEP 1 ( Refer diagram 1 )

  1.  Before installation, remove the rubber wheel and plastic plug from both side of the hanging tube.Rubine RCF NAUSCA54 5B Ceiling Fan - Feager1 Diagram 1

STEP 2 ( Refer diagram 2 )

  1. Place the lead wire and safety cable separately into both side of plastic plug.
  2. Insert the plastic plug into the motor shaft, position the two holes of plug aligning it to the shaft holes. Place the lead wire and safety cable out the top of hanging tube. Insert the hanging tube into plastic plug and aligning shaft holes  to plastic plug holes. Screw the hanging tube to motor with the previous bolt, washer, nut and R-pin.

Rubine RCF NAUSCA54 5B Ceiling Fan - Feager2

NON-LIGHT MODEL ( RCF-NAUSCA54-5B )

STEP 3 ( Refer diagram 3 )
Connect wiring by plug in connector into position.Rubine RCF NAUSCA54 5B
Ceiling Fan - Feager3

STEP 4 ( Refer diagram 4 )

Unscrew all “pre-assemble blade screw” from fan motor, and fix blade to fan motor by tighten the screw firmly. Repeat this step for all blade.Rubine RCF
NAUSCA54 5B Ceiling Fan - Feager4

LIGHT MODEL ( RCF-NAUSCA54-5BL )

STEP 5 ( Installation Of Light LED )

Rubine RCF NAUSCA54 5B Ceiling Fan - Feager5

a. Remove the 3 mounting screws of the light kit plate on the motor, install the light kit plate with LED assembly on the motorman tighten the screws.

Rubine RCF NAUSCA54 5B Ceiling Fan - Feager6

b. Plug the light kit LED wires connector into the LED socket above the LED light source board, and make sure it is firmly plugged in place.Rubine RCF
NAUSCA54 5B Ceiling Fan - Feager7

c. Align the bayonet of the light cover with the bayonet of the lamp plate and support it upward. After it is in place, rotate the lamp shade clockwise until it is clamped.

PRODUCT DIMENSION DIAGRAM

Rubine RCF NAUSCA54 5B Ceiling Fan - PRODUCT

Dimension RCE-NAUSCA54
A 150mm
B 350mm
C 305mm
D 1371mm

RF TRANSMITTER

Rubine RCF NAUSCA54 5B Ceiling Fan - Feager8

1 0 LED Indicator Light
2 To switch fan direction from forward to reverse and vice versa.
3 Increase the fan speed from speed 1 to speed 6.
4 Increase the fan speed from speed 7 to speed 9.
5 Switch off the ceiling fan.
6 Turn ON / OFF the LED lamp & Change the LED.
7 LED color temperature conversion, press this button LED to white light (

For light model only ) .
8| | LED color temperature conversion, press this button LED to neutral light ( For light model only ) .
9| | LED color temperature conversion, press this button LED to yellow light ( For light model only ) .
10| | Sleep Mode (auto reduce and maintain at speed 2 after 1 hour from initial speed

Rubine RCF NAUSCA54 5B Ceiling Fan - icon9

This fan is operated using remote control.

Note – In the event of Transmitter ( Remote Control ) / Receiver cannot be control, please follow the “Remote Control Pairing Procedure” as below :

  1. Insert 2 units of AAA battery into the remote control.
  2. Switch on the ceiling fan ( Power Supply ).
  3. Press the OFF button on the remote control within 30 seconds after power “Switch On” and hold for about 5 seconds until you hear a “Beep” sound. Pairing completed.

Precaution

  1. Last Memory Function – this function records the last function mode when power has been disconnected and the fan will maintain as last function used upon power is restored.(This function does not include LED lights)
  2. Battery – remove the battery from the transmitter ( remote control ) when left unused for more than 5 days to prevent battery leaking to damage the transmitter.
  3. function – to change the direction of rotation ( R / F function ), the fan needs to come to complete stop before the reverse function take effect.
  4. Only 2 remote can be paired with a given fan at any time.

IMPORTANT

DO NOT CONNECT THIS CEILING FAN REMOTE CONTROL TO DIMMER SWITCH OR WALL REGULATOR.

Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of gypsum board ceilings, and all parts must be locked.

WRONG INSTALLATION

Do not install ceiling fan under dome, slanted ceiling, too high or low distance as it will cause turbulence air flow and inefficient low air performance circulation.
a ) Ceiling Fan must be mounted above 2.5m from the floor 1m from the wall to the blade.

b ) Avoid fixing inside a dome ceiling.

c ) Avoid Installing on a deep tray ceiling.

d ) Avoid installing on a slanted ceiling.

Our Warranty

2yrs
Warranty| FOR FAN MOTOR ONLY
---|---
2yrs
Warranty| FOR RECEIVER ONLY
1yr
Warranty| FOR ALL PARTS tacos Accessors»

6 mths Warranty Extension

Online Registration

  1. log on to www.rubine.com.my
  2. Click on ‘Support’, followed by ‘Product Warranty Registration’ to proceed. You’re required to sign up as a member.
  3. You’ll receive a notification of warranty registration confirma­tion via email.
  4. Please keep your on line warranty certificate for reference/future warranty claim.

Customer Care

AFTER-SALES SERVICE:
Tel : 03-6279 8899
Email: ftcrm@fiamma.com.my| OPERATION HOURS:
09:00am – 05:00pm
(Monday Friday, except public holiday)
---|---

rubine.com.my

FIA MMA TRADING SDN BHD 3so476-P
0A member opt rame Hoiauoos foray
2-1, Wisma Fiamma, No.20, Jalan 7A/62A, Bandar
Mangalore, 52200 Kuala Lumpur. Tel: 03-6279 8943

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals