stopBefore You Begin
Read These Instructions Completely and Carefully

Upgrade Instructions

STEP 1: Disconnect power from the luminaire and follow proper lockout/Tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.
STEP 3: Each fixture is supplied with safety cables. Run the one end of the safety cable through the safety cable connector.
STEP 4: Run the free end of the safety cable through the hole on the top side of the fixture.
STEP 5: Loop the safety cable over/through the structure which will support the weight of the fixture.
STEP 6: Press on the safety cable connector end and insert the safety cable through the connector. Pull the excess amount of wire through the connector. Release the safety cable connector end. Pull on the cable to ensure the safety cable is secure.

VENTURE LIGHTING VRK001 C10 413D Linear Highbay Fixture
-

STEP 7: Each fixture is supplied with 1-10V DC dimming leads.
– If dimming is not needed, nothing needs to be done.
NOTE: Do NOT connect the dimming leads together. This will cause the fixture to not operate as desired.
– If dimming is desired:
a) Connect the “+” supply lead to the “+” connection lead on the fixture.
b) Connect the “-” supply lead to the “-” connection lead on the fixture.
NOTE: The polarity of the dimming leads is important.
Improper connection will cause the fixture to not operate as desired.

Wiring Diagram

VENTURE LIGHTING VRK001 C10 413D Linear Highbay Fixture - Wiring
Diagram

STEP 8: Power can now be restored to the fixture.

WARNING

Risk of fire and electric shock

  • Disconnect power from the luminaire and follow proper lockout/Tagout procedures before beginning installation or maintenance.
    Contact a qualified electrician for installation.

  • Venture Lighting’s LED Linear Highbay Fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

  • Do not make or alter any open holes in a wiring enclosure or electrical component during installation.

  • Do not dismantle the fixture without Venture Lighting’s approval.

CAUTION

  • Suitable for use in damp and dry locations only.
  • Venture Lighting’s LED Linear Highbay Fixture must be operated within an ambient fixture temperature range of -30° to 50°C.

800-451-2606
7905 Cochran Road
Glenwillow, Ohio 44139 USA
E-mail: Venture_Lighting@VentureLighting.com
VentureLighting.comhttp://www.venturelighting.com/
© 2022 Venture Lighting International • Venture Lighting is a registered trademark of Venture Lighting International.
AP0005-B

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

VENTURE LIGHTING User Manuals

Related Manuals