VENTURE LIGHTING’S HIGH BAY FIXTURE
USER MANUAL
Before You Begin
Read These Instructions Completely and Carefully
Upgrade Instructions
STEP 1: Disconnect power from the luminaire and follow proper
lockout/Tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and
ballast(s) per local requirements.
STEP 3: Each fixture is supplied with a carabiner (1). Place the
carabiner through the eyelet of the eyebolt (2) on top of the fixture.
STEP 4: Attach the carabiner to a secure structure.
STEP 5: Connect the fixture input leads to the supply wire leads.
STEP 6: Each fixture is supplied with 1-10V DC dimming leads.
– If dimming is not needed, nothing needs to be done.
NOTE: Do NOT connect the dimming leads together.
This will cause the fixture to not operate as desired.
– If dimming is desired:
a) Connect the “+” supply lead to the “+” connection lead on the fixture.
b) Connect the “-” supply lead to the “-” connection lead on the fixture.
NOTE: The polarity of the dimming leads is important.
Improper connection will cause the fixture to not operate as desired.
Wiring Diagram
STEP 7: Loop the safety cable through the opening on the side of the
fixture as shown. Attach the opposite end of the safety cable to a secure
structure. (3)
STEP 8: Power can now be restored to the fixture.
Reflector Installation
- Remove 3 of the screws which hold down the lens (remove every other screw).
- Place the reflector onto the fixture and secure it to the fixture with the 3 longer screws supplied with the reflector.
Lens Installation
Pendant Mount Installation
- Remove the eyebolt from the fixture.
- Secure the pendant bracket to the fixture using the hardware provided.
- Insert the pendant connector into the pendant bracket and secure the pendant connector to the bracket with the hardware provided.
- Screw in the appropriate threaded conduit fitting/pipe and secure with the locking screw.
- Complete the installation of the assembled pendant fixture by following the installation instructions above.
Safety Cable Assembly
WARNING
Risk of fire and electric shock
-
Disconnect power from the luminaire and follow proper lockout/Tagout procedures before beginning installation or maintenance.
Contact a qualified electrician for installation. -
Venture Lighting’s High Bay Fixture installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
-
To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
-
Do not make or alter any open holes in a wiring enclosure or electrical component during installation.
-
Do not dismantle the fixture without Venture Lighting’s approval.
-
If the external flexible cable of the luminaire is damaged, it should only be replaced by the supplier, a service agent or a Venture Lighting approved qualified person.
CAUTION
- Suitable for use in wet locations only.
- Venture Lighting’s High Bay Fixture must be operated within an ambient fixture temperature range of -30° to 50°C.
800-451-2606
7905 Cochran Rd., Suite 300
Glenwillow, Ohio 44139 USA
E-mail:
Venture_Lighting@VentureLighting.com
VentureLighting.com
http://www.venturelighting.com/
© 2022 Venture Lighting International
Venture Lighting is a registered trademark of Venture Lighting International.
AP0001-D
Documents / Resources
|
VENTURE LIGHTING LED Highbay Fixture
50deg
[pdf] User Manual
LED Highbay Fixture 50deg, LED Highbay Fixture, Highbay Fixture, Fixture
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>