ARROW DLX-45563-VPSB Pressure Injectable ard Blue Advance Instruction Manual

June 13, 2024
Arrow

ARROW DLX-45563-VPSB Pressure Injectable and Blue Advance

Product Information

  • Product Name : ADVANCE
  • Features: Antimicrobial, Antithrombogenic
  • Model : DLX-45563-VPSB
  • Catheter Size: 6 Fr.
  • Lumen: Single lumen
  • Catheter Length: 55 cm
  • Guide Wire: Nitinol spring-wire guide, .018 inch dia., 45 cm length, with straight soft tip on one end and straight stiff tip on the other
  • Contents:
    • 1 GlideThruTM Peel-Away Sheath: 6 Fr. x 2-3/4 (7 cm) Radiopaque over 6 Fr. Dilator
    • 1 Spring-Wire Guide, Nitinol, Marked: .018 (0.46 mm) dia. x 17-3/4 (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer

Product Usage Instructions

  1. Prepare the patient and gather all necessary equipment.
  2. Ensure the catheter is sterile and intact.
  3. Choose the appropriate size of the catheter based on the patient’s needs.
  4. Insert the GlideThruTM Peel-Away Sheath into the desired insertion site.
  5. Gently advance the sheath while holding the dilator in place.
  6. Once the sheath is in place, remove the dilator.
  7. Insert the spring-wire guide into the sheath, ensuring the straight soft tip is inserted first.
  8. Advance the spring-wire guide to the desired location, using the arrow advancer for guidance.
  9. Once the guide wire is in place, remove the sheath.
  10. Proceed with the intended medical procedure using the guide wire as needed.
  11. After the procedure, remove the guide wire carefully.

Note : Please refer to the complete user manual for detailed instructions and safety precautions. Always follow proper aseptic techniques during catheter insertion and removal.

Pressure Injectable Arrowg+ard Blue Advance® Three-Lumen PICC pre-loaded with Arrow® VPS Precision™ Stylet

Contents

  • Three Lumen TaperFree® Catheter‡‡‡ with Arrowg+ard Blue Advance® Antimicrobial/Antithrombogenic Protection1: 6 Fr. (2.11 mm OD) x 55 cm, Pressure Injectable, Contamination Guard, Arrow® VPS Precision™ Stylet, Tuohy-Borst Adapter, Stiffening Stylet (0.36 mm dia x 75 cm with straight distal tip) and T-Port Connector
  • 1: GlideThru™ Peel-Away Sheath: 6 Fr. x 2-3/4″ (7 cm) Radiopaque over 6 Fr. Dilator
  • 1: Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer
  • 1: Injection Needle: SafetyGlide™2 25 Ga. x 5/8″ (1.60 cm) RW
  • 1: Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  • 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
  • 1: Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  • 1: Syringe: 5 mL Luer-Lock
  • 4: 10 mL Luer-Lock Pre-Filled Saline Syringe
  • 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
  • 1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution
  • 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with
  • Hi-Lite Orange™ Tint
  • 3: Dust Cap: Non-Vented
  • 1: SharpsAway® Disposal Cup
  • 1: SharpsAway® II Locking Disposal Cup
  • 1: Catheter Trimmer
  • 1: Towel: 24″ x 36″ (61 cm x 91 cm)
  • 1: Maximal Barrier Drape™ with two 13 cm (5″) x 15 cm (6″) fenestrations
  • 1: Safety Scalpel: #11
  • 1: Sterile Procedure Sign1: Patient ID Card
  • 1: Patient Information Booklet
  • 1: Medication Label: 1% Lidocaine
  • 2: Paper Tape Measure
  • 1: Tourniquet
  • 1: Foam Electrodes (3 per pack)
  • 10: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
  • 10: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  • 1: Surgical Apparel: Impervious Gown
  • 1: Dressing: I.V. Advanced 8.5 cm x 11.5 cm
  • 1: Dressing: BIOPATCH®4
  • 1: Transducer Cover with Gel and Rubber Bands
  • 1: Surgical Apparel: Mask with Eye Shield
  • 1: Dressing: STATLOCK®5 PICC Plus Catheter Stabilization Device
  • 1: Surgical Apparel: Bouffant Cap
  • 1: Surgical Apparel: Mask
  • 1: Tape: Steri-Strip®6
  • 1Licensed under US Patent No. 7,329,412 and 11,219,706.
  • 2A trademark of Becton, Dickinson and Company.
  • 3A registered trademark of CareFusion or one of its subsidiaries.
  • 4A registered trademark of Johnson & Johnson Corporation.
  • 5A registered trademark of C. R. Bard, Inc.
  • 6A registered trademark of 3M Company.

INSTRUCTIONS

  • Priming volumes are approximate and are done without accessories.
  • Flow rate values are approximate and are determined using deionized water at 100 cm head height.
  • Pump flow rates are determined at a maximum pump pressure of 10 psig and represent approximate flow capabilities.
  • Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.

MR Safe
Not made with natural rubber latex.
Store between 20 – 25°C (68 – 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.

Contraindications : The Pressure Injectable Arrowg+ard Blue Advance antimicrobial/anti-thrombogenic catheter is contraindicated:

  • For patients with known hypersensitivity to chlorhexidine
  • In the presence of device-related infection in the intended insertion vessel or catheter pathway
  • In the presence of thrombosis in the intended insertion vessel or catheter pathway

LBL071557 R00 (2023-05)