CORBETT 415-23-GL Pandora Gold Leaf Chandelier Instruction Manual
- June 13, 2024
- CORBETT
Table of Contents
CORBETT 415-23-GL Pandora Gold Leaf Chandelier
Product Information
The product is a lighting fixture manufactured by Hudson Valley Lighting Group. It is part of the Corbett collection. The product includes various parts such as mounting plate, mounting screws, screw collar, collar loop, hex nut, nipple, chain, canopy, ground screw, SPT wire, wire nut, bulb, and glass drop. Each part has a specific replacement part name and number for easy identification.
Product Usage Instructions
- Fixture Installation:
- Mount the fixture on a heavy-duty junction box rated for a minimum of 90lbs.
- Use the provided mounting plate (A) and secure it with the mounting screws (B).
- Attach the screw collar (I) to the collar loop (H).
- Connect the nipple (C) to the mounting plate (A) using a tooth washer (D) and secure it with a hex nut (E).
- Attach the canopy (J) to the nipple (C) using a chain (K), screw collar (I), collar loop (H), and hex nut (E).
- Grounding:
- Connect the ground wire to the provided ground screw (F) on the mounting plate (A). Never connect the ground wire to the hot wire to avoid serious injury or death.
- Wiring:
- Ensure there are no exposed wires or strands that could cause a dangerous short circuit.
- Connect the SPT wire with no writings to the wire nut (G).
- Never reverse the hot and neutral wires to avoid serious injury or death.
- Bulb Installation:
- Insert a 60-watt type B lamp into the socket of the fixture assembly (L). Do not exceed the recommended wattage.
- Glass Replacement:
- Refer to the glass schedule page for specific glass drop replacements (A, B, C) and their corresponding numbers (GLS-5-A, GLS-5-B, GLS-5-C).
INSTRUCTIONS
WARNING/CAUTION
- DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE.
- READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
- TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES.
- THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
- CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM.
- WASH HANDS AFTER USE.
- UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON.
- MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE.
- HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED.
- SEE WARRANTY FOR EXCEPTIONS.
- PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.
FIXTURE INSTALLATION
- Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on heavy duty junction box rated for a minimum 90lbs. The junction box must be securely mounted to the structure of the building.
- Remove the SCREW COLLAR (1) from the COLLAR LOOP (H). Fully thread the NIPPLE (C) onto the COLLAR LOOP (H). Thread the HEX NUT (E) onto the NIPPLE (C) along with TOOTH WASHER (D). Then thread the NIPPLE (C) unto the MOUNTING PLATE (A). Adiust the NIPPLE (C) so that the threads of the COLLAR LOOP (H) extends 1/4″ beyond the CANOPY (J). Secure using HEX NUT (E).
- Open the end link the of the CHAIN (K) and attach to the FIXTURE ASSEMBLY (L) at the desired height. Slide the SCREW COLLAR (I) and the CANOPY (J) onto the CHAIN (K). Open the link on other end of the CHAIN (K) then attach unto the COLLAR LOOP (H). Feed the wires through the CHAIN (K), SCREW COLLAR (I), CANOPY (J), COLLAR LOOP (H), NIPPLE (C), and MOUNTING PLATE (A).
- Cut off excess wires, and strip the insulation off the end of the leads.
- Attach the Ground wire to the ground inside the junction box (Generally green or bare copper wire) or the GROUND SCREW (F) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
- Connect the fixture’s SPT Neutral (SP WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (G). Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
- Connect the fixture’s SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
- Push the wires back into the junction box. Lift up the CANOPY (J) up to the ceiling, and screw the SCREW COLLAR (I) onto the COLLAR LOOP (H).
- Screw the BULB (M) into the SOCKET of the FIXTURE ASSEMBLY (L). THIS FIXTURE IS RATED FOR 60 WATT TYPE B LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
- Aftach the GLASS to the FIXTURE ASSEMBLY (L). (See the GLASS SCHEDULE PAGE)
- Restore power to the ouflet at the breaker or fuse box.
Pandora 415-23 Installation Instructions
PART(S) | REPLACEMENT PART NAME | NUMBER |
---|---|---|
A,B,C,D,E,F,G,H,I | HARDWARE KIT | HDW-415-23 |
K | CHAIN | CHN-415-23 |
J | CANOPY | CPY-415-23 |
PART(S) | REPLACEMENT PART NAME | NUMBER |
--- | --- | --- |
A | GLASS DROP A | GLS-415-23-A |
B | GLASS DROP B | GLS-415-23-B |
C | GLASS DROP C | GLS-415-23-C |
Pandora 415-23 Glass Schedule