ineLs RFWB-20-G On-Wall Button Controller User Manual

June 4, 2024
inELS

ineLs-logo

ineLs RFWB-20-G On-Wall Button Controller

Characteristics

  • The wireless controller is used to control switches and dimmers (lights, gates, garage doors, blinds, etc.).
  • FWB-20/G: two buttons enable control of two units independently.
  • FWB-40/G: four buttons enable control of four units independently.
  • The flat design with a level base makes it ideal for fast installation on any surface (fixation with adhesive or screws in the installation box).
  • When pressing the button, it sends a set signal (ON / OFF, dimming, time switching OFF / ON, blinds up / down).
  • Sending a command is indicated by a red LED.
  • In LOGUS90 switch frame design (plastic, glass, wood, metal, stone).
  • Option of setting light scenes, where with a single press, you can control units of iNELS RF Control.
  • Battery power supply (3V/CR2032 – included in the supply) with a battery life of around 5 years based on the frequency of use.
  • Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that supports this feature.
  • Communication frequency with bidirectional protocol iNELS RF Control.

Control options

RF controlers can control:

  • switches
    RFSA-11B, RFSA-61B, RFSA-62B, RFSA-61M, RFSA-66M, RFSAI-61B, RFSC-11, RFSC-61, RFUS-11, RFUS-61, RFJA-12B

  • dimmers
    RFDA-73/RGB, RFDA-11B, RFDA-71B, RFDEL-71B, RFDEL-71M, RFDSC-11, RFDSC-71, RFDAC-71B

  • lighting
    RF-RGB-LED-550, RF-White-LED-675

Radio frequence signal penetration through various construction materials

ineLs-RFWB-20-G-On-Wall-Button-Controller-fig-1

Insertion and replacement of a battery

RFWB-20 / RFWB-40

  1. Using a screwdriver, carefully pry off the device from the frame.
  2. Gently pull to remove the cover.
  3. Slide the CR2032 battery into the battery holder. Observe the polarity.
  4. Snap on the cover. The LED opening must be located in the upper part (for the RFWB-40, observe the positioning of the left and right cover).
  5. Place the frame on the rear part.
  6. Snap the device with the cover into the prepared frame.

Safe handling

When handling a device unboxed it is important to avoid contact with liquids. Never place the device on the conductive pads or objects, and avoid unnecessary contact with the components of the device.

Technical parameters

  • Comes with plastic frame. No installation into multi-frames.

Attention:
When you install the iNELS RF Control system, you have to keep a minimal distance 1 cm between each unit. Between the individual commands must be an interval of at least 1s.

Indicators, settings
After inserting the battery, the red LED lights up continuously for 3 seconds, and then for 5 seconds, the selected controller function is indicated by fl ashing LED. triple fl ash – standard RFIO operating mode rapid fl ashing – mode of compatibility with older actuators If you do not want to change the function of the controller, you must not press any buttons during this time To switch between RFIO mode and compatibility mode: If you need to change the operating mode of the controller, after inserting the battery, when the LED is constantly lit. Press buttons 1 and 2 simultaneously and hold until the LED starts to signal the changed mode (double fl ash or rapid fl ash). Then the buttons must be released. The selected function mode is stored in memory and after replacing the battery, the controller continues to operate in the same mode. If the controller is used in RFIO mode, then it is necessary to instruct the controller and link to the actuators to switch to learn mode not only the actuator (according to the instructions for the actuator), but also the controller in the following way: Remove the battery from the controller, press some of the buttons several times to discharge the internal capacitors and replace the battery. When the LED lights up, press button 1 and keep it pressed until the controller starts signaling the learning mode with short fl ashing LEDs. Then release the button and the button now works in RFIO learning mode. To end the learning mode, remove the battery, and press some of the buttons several times. and then replace the battery. Now we press any button and the controller will start again in RFIO operating mode.

Warning

The instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. The trouble-free function of the device also depends on transportation, storing, and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting the installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives, and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to the transmissivity of RF signals, observe the correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation in exteriors and humid spaces. They must not be installed into metal switchboards and into plastic switchboards with metal doors – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. the radiofrequency signal can be shielded by an obstruction, interfered, a battery of the transceiver can get fl at, etc., and thus disable the remote control. ELKO EP declares that the RFOWB-20 type of equipment complies with Directives 2014/30/EU, 2011/65/EU, 2015/863/EU, and 2014/35/EU. The full EU Declaration of Conformity is available at: https://www.elkoep.com/controller-rfwb