A APPLICATION & SAFETY INSTRUCTION
APPLICATION:
- The powerCON system is certified as a connector with breaking capacity according IEC / EN / UL / CSA-C22.2 No. 60320-1.
- It is intended for use as an appliance coupler and interconnection coupler.
- It serves to supply power to an appliance and from an appliance to other equipment.
- To be installed by qualified person only.
Connector Combination & Keyways:
With the two non-interchangeable types of connectors (A type and B type) it is impossible to produce a short circuit. Mating connectors (combination) are identified by mechanical keyways and by color.
-
APPLIANCE INLET
-
APPLIANCE OUTLET
Approval based:| IEC/EN 60320-1| UL 60320-1 CAN/CSA-C22.2 No.
60320-1
---|---|---
Rating:| 250 V ac / 16 A| 127 V ac / 20 A
Wire size:| 1.5 – 2.5 mm2| 16 – 12 AWG
Cable O.D.:| -S:| 6.0 – 12.0 mm (0.24 – 0.47″)| 6.0 – 12.0 mm (0.24 –
0.47″)
-L:| 10.0 – 16.0 mm (0.39 – 0.63″)| 10.0 – 16.0 mm (0.39 – 0.63″)
CABLE LIST
Cable: IEC/EN 60320-1 | 3 x 1.5 mm2 | 3 x 2.5 mm2 |
---|---|---|
H07RN-F | -S | -L |
H05RN-F | -S | – |
H05VV-F | -S | -S |
Cable: UL 60320-1, CAN/CSA-C22.2 No. 60320-1 | 16/3 AWG | 14/3 AWG |
--- | --- | --- |
SOOW | -S | -L |
SJOOW | -S | -S |
SJTOOW | -S | -S |
ASSEMBLY INSTRUCTION I Locking 3 pole powerCON
B ASSEMBLY INFORMATION
Place the bushing (1) and chuck (2) over the cable.
Important: Chuck and Bushing cannot be placed over the cable after the assembly of the insert.
Prepare cable as shown.
(3) For easier assembly please use a cable lubricant.
-
IEC/EN 60320-1
-
UL60320-1
CAN/CSA-C22.2 No. 60320-1
-
IEC/EN 60230-1
-
**UL60320-1
CAN/CSA-C22.2 No. 60320-1
**
Slide the cable into the contacts and clamp with the screw with Torx size T8.
Typical Wiring| IEC/EN 60230-1| UL60320-1 CAN/CSA-C22.2 No.
60320-1
---|---|---
L P| brown| black
N P| blue| white
P| green/yellow| green
Position chuck (1) on insert (2).
Slide insert (2) with chuck (1) together into housing (3).
Important: Align the chuck by positioning the nose into keyway.
Slide bushing (4) over chuck (1).
Hold the connector with the NEUTRIK tool (5) and tighten bushing with the
NEUTRIK tool (6) as shown.
For an exact mounting position use a torque wrench with 27 mm (1 1/8 inch) hex
bit (7) and tighten it with 2.5 Nm (22 inch pound / 1.8 lb-ft).
NEUTRIK tool Information:
(5)| HTLACA|
(6)| HTLACB|
C DISASSEMBLY INFORMATION
FOR DISASSEMBLY!
- Use the Neutrik tool HTLACB.
- Position the tool on the surfaces and open the clamping sleeve.
D SAFETY INFORMATION
CAUTION
To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no freedangling cable windings etc.).
SAFETY WARNING
For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear.
E More Information on the www.neutrik.com
https://www.neutrik.com/products/audio/powercon
Neutrik AG LI
Neutrik USA Inc. USA
Neutrik UK Ltd. UK
Neutrik Vertriebs GmbH DE/NL/AT/DK
T: +423 / 237 24 24 F: +423/232 53 93
T: +1 704 / 972 3050 F: +1 704/438 9202
T: +44 1983 / 811 441 F: +44 1983/811 439
T: +49 8131 / 280 890 F: +49 8131/280 830
Neutrik France FR
Neutrik Tokyo Ltd. JP
Neutrik Hong Kong Ltd . HK
T: +33 1/4131 6750 F: +33 1/4131 0511
T: +81 3/3663 4733 F: +81 3/3663 4796
T: +852/2687 6055 F: +852/2687 6052
Draft. Nr.: BDA 639 V1 I Update: 2022-11-16 I Data subject to change without
prior notice. 2022 NEUTRIK . NEUTRIK are registered trademark of Neutrik AG.
ALL RIGHTS RESERVED. © ® ®
http://www.neutrik.com/
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>