Installation Plan Commercial Tumble Dryers
Installation notes
Installation requirements
Risk of injury or damage to property due to improper installation.
Incorrect installation of the tumble dryer can lead to personal injury or
damage to property.
The tumble dryer must only be installed and commissioned by Miele Customer
Service Department or an authorised dealer.
The tumble dryer must be installed in accordance with all relevant regulations
and standards.
- The dryer must only be operated in a room that has sufficient ventilation and which is frost-free.
- The tumble dryer must not be installed behind a closeable door or a sliding door. The maximum opening angle of the tumble dryer door must not be limited by objects or doors. It must be possible to fully open the tumble dryer door at any time.
Electrical connection
The electrical connection must be established by a qualified electrician.
-
The electrical connection may only be made to an electrical system
provided in accordance with all appropriate local and national legislation, regulations and guidelines. Please also observe the regulations set out by your insurance provider and energy supplier, accident prevention regulations, as well as recognised codes of practice. -
Reliable and safe operation of this tumble dryer is only ensured if it has been connected to the mains electricity supply.
The required supply voltage, power rating and fuse rating can be found on the
data plate on the tumble dryer. Ensure that the supply voltage matches the
voltage quoted on the data plate before establishing the electrical connection
to the tumble dryer.
Connection to a supply voltage other than the one quoted on the data plate can
damage the tumble dryer if the voltage is too high.
- If more than one voltage is specified on the data plate, the tumble dryer can be converted for connection to the relevant input voltage.
This conversion must be performed by the Miele Customer Service Department or by an authorised dealer. During the conversion, the wiring instructions given on the wiring diagram must be followed.
Tip: We recommend connecting the tumble dryer to the power supply via a plug and socket so that it is easier to conduct electrical safety checks (e.g. during maintenance or repair work).
It is advisable to connect the product via a suitably rated plug and
socket in accordance with IE C-60309, otherwise for a hardwired connection an
all pole means of isolation must be installed at the site.
An isolation device is a switch which ensures a contact opening of more than 3
mm. These include circuit breakers, fuses and contactors (IEC/EN 60947).
If the mains supply cannot be permanently disconnected, the isolation device (including plug and socket) must be safeguarded against being switched on either unintentionally or without authorisation.
-
The tumble dryer must not be connected to devices such as timers which would switch it off automatically.
If local regulations require that a residual current device (R C D) is installed, a type B residual current device (sensitive to universal current) must be used. -
After installing the tumble dryer, equipotential bonding must be established. The equipotential bonding must comply with the local and national installation specifications.
Air intake/exhaust air
The tumble dryer may only be operated when the ducting has been connected
properly and the room is sufficiently ventilated.
- Accessory parts may only be fitted when expressly approved by Miele. If other parts are used, warranty, performance and product liability claims will be invalidated.
PDR 914/514, electrically heated
Dimensions
Dimensions quoted in millimetres
Installation
Electrical connection
Electrically heated
_ Installation (standard/UG)
Dimensions quoted in millimetres
_ Installation (on concrete plinth/offshore) 20 1400
Dimensions quoted in millimetres
Technical data
Possible voltage variants
Voltage variant 1
| Standard connection
---|---
Supply voltage| 3N AC 400 V
Frequency| 50/60 Hz
Power rating| 14.1 kW
Fuse rating (on site)| 3×25 A
Minimum cross-section for connection cable| 5×4.0 mm²
Cable gland| M32
Voltage variant 2
| Standard connection
Supply voltage| 3 AC 230 V
Frequency| 50/60 Hz
Power rating| 14.1 Kw
Fuse rating (on site)| 3×35 A
Minimum cross-section for connection cable| 4×6 mm²
Cable gland| M32
Exhaust air
Maximum nominal volume flow rate in extraction mode (PDR 9xx only)| 580 m³/h
Maximum nominal volume flow rate (PDR 5xx only)| 520 m³/h
Maximum permitted pressure loss| 220 Pa
Connector on machine side (external diameter)| 150 mm
Connection pipe provided on site (internal diameter)| 150 mm
Maximum exhaust air temperature| 80 °C
As relative humidity inside the exhaust ducting can be as high as 100 %,
suitable measures must be taken to prevent a back flow of condensate into the
machine.
Air intake
Standard connection: air intake from installation site
Recommended free air intake cross-section into the room:| 763 cm²
(equivalent to 3 times the exhaust air cross-section of a machine)
There must be sufficient air intake to the installation site to match the air
outlet volume.
Alternative connection: air intake connection directly from outdoors
Connection sleeve on machine side (internal diameter)| 161 mm
Connection pipe provided on site (external diameter)| 160 mm
Removing the protective cover exposes live parts. For safety reasons, a pipe
must be installed from the tumble dryer’s central fresh air intake (over a
minimum length of 900 mm) and secured with 2 screws.
Equipotential bonding (optional)
Connection with male thread| 10×35 mm
Washers and nuts| M 10
Accessories for quintessential bonding are not supplied and need to be ordered
separately.
Peak-load negotiation (optional)
Supply voltage for control contacts | AC 230 V |
---|---|
Minimum cross-section for connection cable | 5×1.5 mm² |
Miele recommends using a flexible connection cable with an additional
isolation option to establish the connection. The isolator should remain
visible once the tumble dryer has been installed and must be freely
accessible.
Machine data
Machine width, total| 906 mm
Machine height, total| 1400 mm
Machine depth, total| 852 mm
Niche width| 1250 mm
Recommended wall spacing (up to the front edge of the machine)| 1300 mm
Minimum wall spacing (up to the back edge of the lid)| 500 mm
Packaging width| 1090 mm
Packaging height| 1526 mm
Packaging depth| 938 mm
Maximum gross volume| 1560.2 l
Maximum gross weight| 171.7 kg
Maximum net weight| 160.4 kg
Max. floor load in operation| 1779 N
Diameter of exhaust duct| 150 mm
Drum diameter| 850 mm
Diameter of drum opening| 520 mm
Drum depth| 480 mm
Drum volume| 250 l
Diameter of door opening| 520 mm
Maximum door opening angle| 180°
Emission sound pressure level| 51 dB(A) re 20 µPa
Sound power level| 62
Average heat dissipation rate into the room| 3.9 MJ/h
Permissible ambient temperature range| 2–40 °C
Fixing options
Fixing without plinth
| Quantity| Screw size
---|---|---
Tensioning strips| 2|
Wood screws DIN 571 (Ø × length)| 2| 6×40 mm
Plugs (Ø × length)| 2| 10×50 mm
If the tumble dryer is being installed without a plinth, fixing it in place is
recommended. Fastenings for floating screed must be supplied by the customer
on site.
Fixing to concrete plinth
| Quantity| Screw size
Tensioning strips| 2| 6×40 mm
Plugs (Ø × length)| 2| 10×50 mm
If the tumble dryer is being fixed to a concrete plinth on site, fixing in
place is absolutely essential. Fastenings for floating screed must be supplied
by the customer on site.
Fixing to Miele plinth
| Quantity| Screw size
Tensioning strips| 4|
Wood screws DIN 571 (Ø × length)| 4| 8×65 mm
Plugs (Ø × length)| 4| 12×60 mm
If the tumble dryer is being fixed to a Miele plinth (optional accessory
available to purchase separately), fixing in place is absolutely essential.
Fastenings for floating screed must be supplied by the customer on site.
Options/Accessories
Miele plinth (optional accessory available to purchase separately)
Width| 900 mm
Height| 127 mm
Depth| 685 mm
Concrete base (on site)
Minimum width| 900 mm
Recommended height| 100 mm
Minimum height| 50 mm
Minimum depth| 900 mm
The quality of the concrete and its strength must be assessed according to the
machine load. The on-site concrete plinth must be fixed adequately to the
floor.
Miele & Cie. KG
Carl-Miele-Straße 29
33332 Gütersloh
Germany
Telefon: 05241 89-0
Internet: www.miele.com/professional