Product Usage Instructions

  1. Attach the MOUNTING PLATE (A) unto the junction box using the MOUNTING SCREWS (B). Ensure that the junction box is securely mounted to the building structure.
  2. Attach the Ground wire (Green) to the ground inside the outlet box or the GROUND SCREW (C) on the MOUNTING PLATE (A). Never connect the ground wire to the hot wire to avoid serious injury or death.
  3. Connect the white fixture lead to the neutral wire in the outlet box. Use an approved fastener (WIRE NUT) (D) to fasten the wires together. Wrap the connection with electrical tape starting 1 inch below the fastener to seal the end and prevent short circuits.
  4. Connect the black fixture leads to the hot wire in the junction box. Fasten the joined wires as done in the previous step. Ensure hot and neutral wires are not reversed to avoid serious injury or death.
  5. Attach the FIXTURE ASSEMBLY (G) to the MOUNTING PLATE (A) and secure with the SET SCREWS (E).
  6. Screw the ROD (F) to the FIXTURE ASSEMBLY (G) of the fixture.
  7. Screw the BULB (H) into the SOCKET of the fixture. Use only watt type B lamps and do not exceed the recommended wattage.
  8. Place the SHADE (I) over the BULB (H) of the fixture.
  9. Restore power to the outlet at the breaker or fuse box.

Note: For replacement parts, refer to the Hardware Kit (HDW-H759101) or Shade (SHD-H759101).

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

Installation Instructions

HUDSON-VALLEY-H759101-Banyan-Wall-Sconce-FIG-1

PART(S) REPLACEMENT PART NAME NUMBER
A,B,C,D,E HARDWARE KIT HDW-H759101
I SHADE SHD-H759101

FIXTURE INSTALLATION

  1. Attach the MOUNTING PLATE (A) unto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
  2. Attach the Ground wire (Green) to the ground inside the outlet box Generally green or bar copper wire) or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
  3. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT (D). Starting I” below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
  4. Connect the black fixture leads to the hot Generally black wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
  5. Attach the FIXTURE ASSEMBLY (G) to the MOUNTING PLATE (A) and secure with the SET SCREWS (E).
  6. Screw the ROD (F) to the FIXTURE ASSEMBLY (G) of the fixture.
  7. Screw the BULB (H) into the SOCKET of the fixture. THIS FIXTURE IS RATED FOR 8 WATT TYPE B LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
  8. Place the SHADE (I) over the BULB (H) of the fixture.
  9. Restore power to the outlet at the breaker or fuse box.