ELATION PROFESSIONAL SIXPAR 300IP LED Fixture User Manual

June 13, 2024
ELATION PROFESSIONAL

SIXPAR 300IP LED Fixture

Product Information: SIXPAR 300IPTM

The SIXPAR 300IPTM is an innovative and reliable ArtNet to DMX
converter. It has been designed to perform reliably for years when
the guidelines in the user manual are followed.

General Information

  • Introduction

  • IP65 Rated – Not suitable for marine and/or coastal environment
    installations

  • Optional Corrosion-Resistant Coating available

Warranty

ELATION PROFESSIONAL and all affiliated companies disclaim any
and all liabilities for damages, injuries, and economic loss
associated with the use or reliance of any information contained
within the user manual. Please contact ELATION SERVICE USA for
warranty-related inquiries.

Safety Instructions

Please read and understand the instructions in this manual
carefully and thoroughly before attempting to operate the SIXPAR
300IPTM. These instructions contain important information regarding
safety during use and maintenance.

Fixture Overview

The user manual provides detailed information on the fixture’s
installation, DMX channel functions, cleaning and maintenance,
technical specifications, and optional accessories.

Contact Information

ELATION SERVICE USA is available from Monday to Friday, 8:00am
to 5:00pm PST.

E L A T I O N | SIXPAR 300IPTM | user manual

SIXPAR 300IPTM

user manual

Search

www.elationlighting.com
©2015 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | [email protected]
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | [email protected]

DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.

Date

Document Version

Software Version

DMX Channel Modes

2/2015

1

1.03

6/7/8/12

Initial release.

Notes

2

Search

SIXPAR 300IPTM User Manual ver 1

CONTENTS

www.elationlighting.com

General Information

4

Warranty

7

Safety Instructions

8

General Guidelines

9

Fixture Overview

10

Fixture Installation

11

Understanding DMX

13

Fixture Menu

16

DMX Channel Functions And Values

19

Cleaning and Maintenance

22

Technical Specifications

23

Optional Accessories

25

3

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and reliable ArtNet to DMX converter on the market today! The SIXPAR 300IPTM has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is one, which has been designed and tested to protect against the ingress of dust (6) and high- pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for marine and/or coastal environment installations. Installing this fixture in a marine and/or coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and/or repairs.
Ensure ALL connections and end caps are properly sealed with a non-conductive dielectric grease (available at most electrical suppliers) to prevent water ingress/condensation and/or corrosion.
OPTIONAL CORROSION-RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture. Please consult your Elation Professional sales representative for details.

4

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
UNPACKING Thank you for purchasing the SIXPAR 300IP TM by Elation Professional®. Every SIXPAR 300IPTM has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this unit to your dealer without first contacting customer support at the number listed below. Please do not discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS · Male Edison to IP Female Power Cable 6,6 ft. (2m) · Male 3pin XLR to IP Female DMX Input Cable 3.3 ft (1m) · Female 3pin XLR to IP Male DMX Output Cable 3.3 ft (1m) · Manual & Warranty Card

CUSTOMER SUPPORT Elation Professional® provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional®.

ELATION SERVICE USA – Monday – Friday 8:00am to 5:00pm PST

Voice: 323-582-3322

Fax: 323-832-9142

E-mail: [email protected]

ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET

Voice: +31 45 546 85 30

Fax: +31 45 546 85 96

E-mail: [email protected]

5

SIXPAR 300IPTM User Manual ver 1

Search

www.elationlighting.com
WARRANTY REGISTRATION Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support at 323-582-3322.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any
repairs yourself; doing so will void your manufactures warranty. Damages
resulting from modifications to this fixture and/or the disregard of safety and
general user instructions found in this user manual void the manufactures
warranty and are not subject to any warranty claims and/or repairs.

6

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional® product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional® concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional® factory unless prior written authorization was issued to purchaser by Elation Professional®; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional® will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect. E. Elation Professional® reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional® in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

7

SIXPAR 300IPTM User Manual ver 1

Search

www.elationlighting.com
SAFETY INSTRUCTIONS
The SIXPAR 300IPTM is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. This device falls under PROTECTION CLASS 1. It’s essential this device be grounded properly. Only qualified personnel should perform all electrical connections.
CAUTIONS
UNPLUG POWER BEFORE SERVICING FIXTURE
NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK
· For proper operation, follow the Installation guidelines described in this manual. Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts (brackets) included with this fixture should be used for installation. Any modifications will void the original manufactures warranty and increase the risk of damage and/or personal injury.
· Never look directly into the light source of this fixture to prevent risk of injury to your retina, which may induce blindness. Those suffering from E P I L E P S Y should avoid looking directly into the light source of this unit at all times.
· Always disconnect from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.
· Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating.

8

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
GENERAL GUIDELINES
· NEVER OPEN THIS FIXTURE WHILE IN USE! · Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion and/or electrical short circuit. · During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time. · Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating, to prevent any fire hazard. · Minimum distance of inflammable materials from the surface 1.6 feet (0.5m). · DO NOT attempt installation and/or operation without knowledge how to do so. · DO NOT allow operation by persons who are not qualified to operate this type of fixture. Most damages are the result of operations by nonprofessionals. · Consistent operational breaks may ensure the fixture will function properly for many years to come. · DO NOT shake fixture, avoid brute force when installing and/or operating fixture. · Always install the fixture with an appropriate safety cable. When installing the fixture in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw holes in the bracket of the fixture. · Use the original packaging and materials to transport the fixture in for service. · DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before replacing or serving.

9

Search

SIXPAR 300IPTM User Manual ver 1

FIXTURE OVERVIEW

www.elationlighting.com

1. MODE Button 2. UP Button 3. DOWN Button 4. ENTER Button 5. Power IN 6. DMX IN 7. DMX Out 8. Power OUT

10

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) away from any flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.
CAUTIONS
· For added protection, mount the fixture in areas outside walking paths, seating areas, or in areas were unauthorized personnel might reach the fixture.
· Min/Max ambient operating temperature for this fixture is 5°F to 113°F (-15°C to 45°C). Do not use the fixture under or above this temperature.
· Before mounting the fixture to any surface, make sure the installation area can hold a minimum point load of 10 times the weight of the fixture. 210 lbs / 95 kg)
· Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
· Never stand directly below the device when mounting, removing or servicing. · Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion and/or electrical short circuit. POWER LINKING Max number of units that can be power linked is 5 units @110V and 10 units @240V.
CLAMP MOUNTING The SIXPAR 300IPTM provides a unique integrated Dual Yoke / Floor Stand. When mounting this fixture to truss be sure to secure an appropriately rated clamp using an M10 screw fitted through the center hole of the Dual Yoke / Floor Stand.

11

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
SECURING Regardless of the rigging option you choose for your SIXPAR 300IPTM always be sure to secure your fixture with a safety cable.
MOUNTING POINTS · Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. · Fixture is fully operational in the specific mounting positions as illustrated below.

SAFETY CABLE
Always use a Safety Cable whenever installing this fixture in a suspended environment to ensure the fixture will not drop if the clamp fails.

12

SIXPAR 300IPTM User Manual ver 1

Search

www.elationlighting.com
UNDERSTANDING DMX
DMX-512 DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant. A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light. DMX data is sent out as serial data that travels from fixture to fixture via data “IN” and data “OUT” XLR terminals located on the fixtures (most controllers will only have output jacks).
DMX LINKING To ensure proper DMX data transmission, always use the SIXPARTM series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual. When using several DMX fixtures try to use the shortest cable path possible. Never split a DMX line with a “Y” style connector. The order in which the fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain, at the beginning, at the end, or anywhere in the middle. The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain. The SIXPAR 300IPTM can be controlled via DMX-512 protocol and the DMX address is set via the control menu.
DATA CABLE (DMX Cable) REQUIREMENTS (For DMX and Master/Slave Operation) Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector for data input and data output (see figure below). Also, remember that a DMX line must be daisy chained and cannot be split.

13

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
DMX-512 CONTROLLER CONNECTION Connect the provided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the SIXPAR 300IPTM. The diagram below illustrates a typical DMX-512 connection when the fixture is in the 12 Channel Mode. You can chain multiple panels together through serial linking. Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections.

DMX CONTROLLER

Address 1

Address 13

Address 25

DMX-512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs. The use of a terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a line terminator will decrease the possibilities of erratic behavior. Use the SIXPARTM DMX Terminator End Cap listed in the OPTIONAL ACCESSORIES section at the end of this manual.

14

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture.
You can set the same starting address for all fixtures or a group of fixtures, or set different address for each individual fixture. Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion, in other words, changing the settings of one channel will affect all the fixtures simultaneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of control channels (DMX channels) of each fixture. That means changing the settings of one channel will only affect the selected fixture.
In the case of the SIXPAR 300IPTM, when in the 12 Channel Mode you should set the starting DMX address of the first unit to 1, the second unit to 13 (1 + 12), the third unit to 25 (13 + 12), and so on.
Note: During start-up the SIXPAR 300IPTM will automatically detect whether a DMX data signal is being received or not. If the fixture is not receiving a DMX signal please check the following:
– The 3pin or 5pin XLR input plug (cable with DMX signal from controller) is not connected or is not inserted completely into the DMX input jack of the fixture.
– The DMX controller is switched off or defective. – The DMX cable or connector is defective. – A DMX terminator has been inserted into the last fixture in your DMX chain.

15

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
FIXTURE MENU
ON-BOARD SYSTEM MENU
The SIXPAR 300IPTM comes with an easy to navigate system menu. The next sections will cover how to access each menu function.
LCD CONTROL PANEL DISPLAY
The (4) button control panel (see image below) located on back of the fixture allows you to access the main menu and make all necessary adjustments to the SIXPAR 300IPTM. During normal operation, pressing the MODE button will navigate through the different function menus. Once you reach a desired menu, press the ENTER button to select that menu. The variable field that can be adjusted within the selected menu will begin to flash. Using the UP or DOWN buttons, adjust the field until the desired value is displayed. For example, the CHANNEL CH: menu variable field can be set to 06, 07, 08, or 12. Pressing the ENTER button once will confirm your selected value. Exit at any time without making any adjustments by pressing the MODE button.

INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON, the display shows the following information:

Update Wait…

SIXPAR 300IP

300IP V1.03
Fixture Software Version (Greater than or equal to)

16

SIXPAR 300IPTM User Manual ver 1

Search

www.elationlighting.com

LCD CONTROL PANEL LOCKOUT When the Display ON menu is set to OFF1, the LCD display will turn OFF after 30 seconds and the (4) button Control Panel will be LOCKED. To unlock the (4) button LCD control panel follow these steps:
1. When locked, the display will show: LOCKED* 2. Press UP, then the display will change to: LOCKED** (one * disappears) 3. Press DOWN, then the display will change to: LOCKED** (two disappear) 4. Press UP, then the display will change to: LOCKED (three disappear) 5. Press DOWN, then the display will change to: LOCKED (4 * disappear) 6. Press ENTER, then the display will change to LOCKED and then become unlocked.

MENU CHANNEL DMX MODE SLAVE MODE Display ON
Internal Programs
DimCurve NO DMX

ELATION© SIXPAR 300 IPTM

SYSTEM MENU

Specifications are subject to change without any prior written notice.

OPTIONS / VALUES

DESCRIPTION

CH: 06, 07, 08, 12

DMX Channel Mode

ADDR: 001 ~ 512

DMX Address Setting

SALVE MODE

Set Fixture A Slave Unit

ON

LCD Display Always ON

OFF

LCD Display OFF after 30 seconds

OFF1

LCD Display OFF After 30 Seconds and LOCKED

1.MANUAL

Manual Color Adjustment

R00-99

Adjust RED Brightness (00-99)

G00-99

Adjust GREEN Brightness (00-99)

B00-99

Adjust BLUE Brightness (00-99)

W00-99

Adjust WHITE Brightness (00-99)

A00-99

Adjust AMBER Brightness (00-99)

U00-99

Adjust UV Brightness (00-99)

S00-99

Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)

2.CHANGE

30 Color Chase Macro

SP01-99

Adjust SPEED 01 SLOW – 99 FAST

S00-99

Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)

3.CHANG6

6 Color Chase Macro

SP01-99

Adjust SPEED 01 SLOW – 99 FAST

S00-99

Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)

4.FADE

Color Fade Macro

SP01-99

Adjust SPEED 01 SLOW – 99 FAST

S00-99

Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)

Standard, Stage, TV, Architec, Theatre

Set Dimming Curve

Blackout

NO Output

Hold

Hold Last Setting

Fade

Fade

17

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com DIMMING CURVES The DimCurve menu allows you to select one of the following preset dimming curves: Standard, Stage, TV, Architec, or Theatre. (See diagram below for more details)
Dimmer

18

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com

DMX CHANNEL FUNCTIONS AND VALUES

ELATION© SIXPAR 300IPTM
DMX Channel Values / Functions (12 DMX Channels)

Specifications are subject to change without any prior written notice.

MODE / CHANNEL 6 CH 7 CH 8 CH 12 CH

1

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

8

8

VALUE

FUNCTION

0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-31 32-95 96-127 128-159 160-191 192-223 224-255

RED Red (0-100%) GREEN Green (0-100%) BLUE Blue (0-100%) WHITE White (0-100%) AMBER
Amber (0-100%) U. V. U. V. (0-100%) MASTER DIMMER Dimmer (0-100%) STROBE LED OFF (NO STROBE) Strobe Effect SLOW to FAST LED ON (NO STROBE) Strobe Pulse Effect In Sequences SLOW to FAST LED ON (NO STROBE) Random Strobe Effect SLOW to FAST LED ON (NO STROBE)

19

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com

6 CH

ELATION© SIXPAR 300IPTM

DMX Channel Values / Functions (12 DMX Channels)

Specifications are subject to change without any prior written notice.

MODE / CHANNEL

VALUE

FUNCTION

7 CH

8 CH

12 CH

COLOR MACROS

0-3

OFF

4-7

RED

8-11

GREEN

12-15

BLUE

16-19

WHITE

20-23

AMBER

24-27

UV

28-31

RED + GREEN

32-35

RED + BLUE

36-39

RED + WHITE

40-43

RED + AMBER

44-47

RED + UV

48-51

GREEN + BLUE

52-55

GREEN + WHITE

56-59

GREEN + AMBER

60-63

GREEN + UV

64-67

BLUE + WHITE

68-71

BLUE + AMBER

9

72-75

BLUE + UV

76-79

WHITE + AMBER

80-83

WHITE + UV

84-87

AMBER + UV

88-91

RED + GREEN + BLUE

92-95

RED + GREEN + WHITE

96-99

RED + GREEN + AMBER

100-103

RED + GREEN + UV

104-107

RED + BLUE + WHITE

108-111

RED + BLUE + AMBER

112-115

RED + BLUE + UV

116-119

RED + WHITE + AMBER

120-123

RED + WHITE + UV

124-127

RED + AMBER + UV

128-131

GREEN + BLUE + WHITE

132-135

GREEN + BLUE + AMBER

136-139

GREEN + BLUE + UV

140-143

GREEN + WHITE + AMBER

144-147

GREEN + WHITE + UV

148-151

GREEN + AMBER + UV

20

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com

ELATION© SIXPAR 300IPTM

DMX Channel Values / Functions (12 DMX Channels)

Specifications are subject to change without any prior written notice.

MODE / CHANNEL

VALUE

FUNCTION

6 CH 7 CH 8 CH 12 CH

COLOR MACROS (continued)

152-155 BLUE + WHITE + AMBER

156-159 BLUE + WHITE + UV

160-163 BLUE + AMBER + UV

164-167 WHITE + AMBER + UV

168-171 RED + GREEN + BLUE + WHITE

172-175 RED + GREEN + BLUE + AMBER

176-179 RED + GREEN + BLUE + UV

180-183 RED + GREEN +WHITE + AMBER

184-187 RED + GREEN + WHITE + UV

188-191 RED + GREEN + AMBER + UV

192-195 RED + BLUE + WHITE + AMBER

196-199 RED + BLUE + WHITE + UV

9

200-203 RED + BLUE + AMBER + UV

204-207 RED + WHITE + AMBER + UV

208-211 GREEN + BLUE + WHITE + AMBER

212-215 GREEN + BLUE + WHITE + UV

216-219 GREEN + BLUE + AMBER + UV

220-223 GREEN + WHITE + AMBER + UV

224-227 BLUE + WHITE + AMBER + UV

228-231 RED + GREEN + BLUE + WHITE + AMBER

232-235 RED + GREEN + BLUE + WHITE + UV

236-239 RED + GREEN + BLUE + AMBER + UV

240-243 RED + GREEN + WHITE + AMBER + UV

244-247 RED + BLUE + WHITE + AMBER + UV

248-251 GREEN +BLUE + WHITE + AMBER + UV

252-255 RED + GREEN + BLUE + WHITE + AMBER + UV

COLOR CHASE MACROS

00-20 NO Function

21-40 30 Color Chase 10
41-60 6 Color Chase

61-80 Color Fade Chase

81-255 NO Function

COLOR CHASE MACROS SPEED 11
00-255 Chase Speed of CHANNEL 10 – SLOW to FAST

DIMMING MODES

0-20

STANDARD

21-40 STAGE

12

41-60 TV

61-80 ARCHITECTURAL

81-100 THEATER

101-255 NO Function

21

Search

SIXPAR 300IPTM User Manual ver 1

www.elationlighting.com
CLEANING AND MAINTENANCE

C

A

U

T

I

O

N

Disconnect power before cleaning or maintenance.

CLEANING Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. · Clean the external lens surface at least every 20 days with a soft cloth to avoid
dirt/debris accumulation. Never use alcohol, solvents, or ammonia based cleaners.

MAINTENANCE Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.

Please refer to the following points during routine inspections: · A detailed electric check by an approved electrical engineer every 3 months, to
make sure the circuit contacts are in good condition and prevent overheating. · Be sure all screws and fasteners are securely tightened at all times. Lose screws
may fall out during normal operation resulting in damage or injury. · Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s). · Inspect all moving parts and make sure there are no signs of wear and rotate/move without imbalances. · Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.

22

SIXPAR 300IPTM User Manual ver 1

Search

www.elationlighting.com
TECHNICAL SPECIFICATIONS
FEATURES IP65 Rated 15° Beam 25° Field Angles 5 Variable Dimming Curve Modes Dual Yoke / Floor Stand Multiple Unit Power Linking RDM – Remote Device Management Rugged Die-Cast Aluminum Exterior Flicker Free Operation for TV and FILM
SOURCE (18) 12W 6-in-1 RGBAW+UV LEDs 100,000 Hour Average LED Life
EFFECTS Electronic Strobe Color and Chase Macros Electronic Dimming: 0% – 100% 5 Variable Dimming Curve Modes
CONTROL / CONNECTIONS (4) DMX Channel Modes (6 / 7 / 8 / 12) (4) Button Touch Control Panel LCD Menu Display IP DMX and Power In/Out
SIZE / WEIGHT Length: 14.4″ (365mm) Width: 6.2″ (157mm) Vertical Height: 14.4″ (365mm) Weight: 21.6 lbs. (9.5 kg)
ELECTRICAL / THERMAL AC 110-250V – 50/60Hz 220W Max Power Consumption Power Linking: 5pcs @110V / 10pcs @240V 5°F to 113°F (-15°C to 45°C)
APPROVALS / RATINGS CE | IP65**

**Optional Corrosion-Resistant Coating may be available for this fixture. Please consult an Elation sales representative for details. Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

23

Search

SIXPAR 300IPTM User Manual ver 1

PHOTOMETRIC DATA

www.elationlighting.com

DIMENSIONAL DRAWINGS

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

24

SIXPAR 300IPTM User Manual ver 1

Search

www.elationlighting.com

OPTIONAL ACCESSORIES

ORDER CODE

ITEM

TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp

SIXPAR300/GFH

Gel Frame and Holder Kit

SIXPAR/BD300

Barn Door (Gel Frame Holder Kit Required – Not Included)

EWD001

EWDMX IP Wireless IP65 DMX Transceiver

SIXPAR/2MDLC

6.6 ft. (2m) IP Data Link Cable

SIXPAR/2MPLC

6.6 ft. (2m) IP Power Link Cable

SIXPAR/3MDLC

9.8 ft. (3m) IP Data Link Cable

SIXPAR/3MPLC

9.8 ft. (3m) IP Power Link Cable

SIXPAR/5MDLC

SPECIAL ORDER ITEM 16.4 ft. (5m) IP Data Link Cable

SIXPAR/5MPLC

SPECIAL ORDER ITEM 16.4 ft. (5m) IP Power Link Cable

SIXPAR/10MDLC SPECIAL ORDER ITEM 32.8 ft. (10m) IP Data Link Cable

SIXPAR/10MPLC

SPECIAL ORDER ITEM 32.8 ft. (10m) IP Power Link Cable

SIXPAR/20MDLC SPECIAL ORDER ITEM 65.6 ft. (20m) IP Data Link Cable

SIXPAR/20MPLC

SPECIAL ORDER ITEM 65.6 ft. (20m) IP Power Link Cable

SIXPAR/DIAC

Data IN IP Adapter Cable

SIXPAR/DOAC

Data OUT IP Adapter Cable

SIXPAR/PIAC

Power IN IP Adapter Cable

SIXPAR/POAC

Power OUT Adapter Cable

SIXPAR/TERMINATOR DMX Terminator End Cap

25

Search

SIXPAR 300IPTM User Manual ver 1

Search

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELATION PROFESSIONAL User Manuals