ELATION PROFESSIONAL SIXPAR 300IP LED Fixture User Manual
- June 13, 2024
- ELATION PROFESSIONAL
Table of Contents
SIXPAR 300IP LED Fixture
Product Information: SIXPAR 300IPTM
The SIXPAR 300IPTM is an innovative and reliable ArtNet to DMX
converter. It has been designed to perform reliably for years when
the guidelines in the user manual are followed.
General Information
-
Introduction
-
IP65 Rated – Not suitable for marine and/or coastal environment
installations -
Optional Corrosion-Resistant Coating available
Warranty
ELATION PROFESSIONAL and all affiliated companies disclaim any
and all liabilities for damages, injuries, and economic loss
associated with the use or reliance of any information contained
within the user manual. Please contact ELATION SERVICE USA for
warranty-related inquiries.
Safety Instructions
Please read and understand the instructions in this manual
carefully and thoroughly before attempting to operate the SIXPAR
300IPTM. These instructions contain important information regarding
safety during use and maintenance.
Fixture Overview
The user manual provides detailed information on the fixture’s
installation, DMX channel functions, cleaning and maintenance,
technical specifications, and optional accessories.
Contact Information
ELATION SERVICE USA is available from Monday to Friday, 8:00am
to 5:00pm PST.
- Voice: 323-582-3322
- Fax: 323-832-9142
- E-mail: support@elationlighting.com
E L A T I O N | SIXPAR 300IPTM | user manual
SIXPAR 300IPTM
user manual
www.elationlighting.com
©2015 ELATION PROFESSIONAL all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. ELATION PROFESSIONAL logo and identifying product names and numbers
herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed
includes all forms and matters of copyrightable materials and information now
allowed by statutory or judicial law or hereinafter granted. Product names
used in this document may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged. All non-ELATION brands and
product names are trademarks or registered trademarks of their respective
companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, Netherlands +31
45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu |
info@elationlighting.eu
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this
manual.
Date
Document Version
Software Version
DMX Channel Modes
2/2015
1
1.03
6/7/8/12
Initial release.
Notes
2
SIXPAR 300IPTM User Manual ver 1
CONTENTS
www.elationlighting.com
General Information
4
Warranty
7
Safety Instructions
8
General Guidelines
9
Fixture Overview
10
Fixture Installation
11
Understanding DMX
13
Fixture Menu
16
DMX Channel Functions And Values
19
Cleaning and Maintenance
22
Technical Specifications
23
Optional Accessories
25
3
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable ArtNet to DMX converter on the market today! The SIXPAR 300IPTM has
been designed to perform reliably for years when the guidelines in this
booklet are followed. Please read and understand the instructions in this
manual carefully and thoroughly before attempting to operate this unit. These
instructions contain important information regarding safety during use and
maintenance.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor
environments and has been designed with an enclosure that effectively protects
the ingress (entry) of external foreign objects such as dust and water. The
International Protection (IP) rating system is commonly expressed as “IP”
(Ingress Protection) followed by two numbers (i.e. IP65) where the numbers
define the degree of protection. The first digit (Foreign Bodies Protection)
indicates the extent of protection against particles entering the fixture and
the second digit (Water Protection) indicates the extent of protection against
water entering the fixture. An IP65 rated lighting fixture is one, which has
been designed and tested to protect against the ingress of dust (6) and high-
pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for
marine and/or coastal environment installations. Installing this fixture in a
marine and/or coastal environment may cause corrosion and/or excessive wear to
the interior and/or exterior components of the fixture. Damages and/or
performance issues resulting from installation in a marine and/or coastal
environment will void the manufactures warranty and will NOT be subject to any
warranty claims and/or repairs.
Ensure ALL connections and end caps are properly sealed with a non-conductive
dielectric grease (available at most electrical suppliers) to prevent water
ingress/condensation and/or corrosion.
OPTIONAL CORROSION-RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture.
Please consult your Elation Professional sales representative for details.
4
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
UNPACKING Thank you for purchasing the SIXPAR 300IP TM by Elation
Professional®. Every SIXPAR 300IPTM has been thoroughly tested and has been
shipped in perfect operating condition. Carefully check the shipping carton
for damage that may have occurred during shipping. If the carton appears to be
damaged, carefully inspect your unit for damage and be sure all accessories
necessary to operate the unit have arrived intact. In the event damage has
been found or parts are missing, please contact our customer support team for
further instructions. Please do not return this unit to your dealer without
first contacting customer support at the number listed below. Please do not
discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS · Male Edison to IP Female Power Cable 6,6 ft. (2m) · Male 3pin
XLR to IP Female DMX Input Cable 3.3 ft (1m) · Female 3pin XLR to IP Male DMX
Output Cable 3.3 ft (1m) · Manual & Warranty Card
CUSTOMER SUPPORT Elation Professional® provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional®.
ELATION SERVICE USA – Monday – Friday 8:00am to 5:00pm PST
Voice: 323-582-3322
Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30
Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
5
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
WARRANTY REGISTRATION Please fill out the enclosed warranty card to validate
your purchase. All returned service items whether under warranty or not, must
be freight pre-paid and accompany a return authorization (R.A.) number. The
R.A. number must be clearly written on the outside of the return package. A
brief description of the problem as well as the R.A. number must also be
written down on a piece of paper and included in the shipping container. If
the unit is under warranty, you must provide a copy of your proof of purchase
invoice. Items returned without a R.A. number clearly marked on the outside of
the package will be refused and returned at customer’s expense. You may obtain
a R.A. number by contacting customer support at
323-582-3322.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any
repairs yourself; doing so will void your manufactures warranty. Damages
resulting from modifications to this fixture and/or the disregard of safety
and
general user instructions found in this user manual void the manufactures
warranty and are not subject to any warranty claims and/or repairs.
6
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation
Professional® products to be free of manufacturing defects in material and
workmanship for a period of two years (730 days), and Elation Professional®
product rechargeable batteries to be free of manufacturing defects in material
and workmanship for a period of six months (180 days), from the original date
of purchase. This warranty excludes discharge lamps and all product
accessories. This warranty shall be valid only if the product is purchased
within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by
acceptable evidence, at the time service is sought. B. For warranty service,
send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts
replacement) are within the terms of this warranty, Elation Professional® will
pay return shipping charges only to a designated point within the United
States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any
accessories are shipped with the product, Elation Professional® shall have no
liability what so ever for loss and/or or damage to any such accessories, nor
for the safe return thereof. C. This warranty is void if the product serial
number and/or labels are altered or removed; if the product is modified in any
manner which Elation Professional® concludes, after inspection, affects the
reliability of the product; if the product has been repaired or serviced by
anyone other than the Elation Professional® factory unless prior written
authorization was issued to purchaser by Elation Professional®; if the product
is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual. D. This is not a service
contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation
Professional® will replace defective parts at its expense, and will absorb all
expenses for warranty service and repair labor by reason of defects in
material or workmanship. The sole responsibility of Elation Professional®
under this warranty shall be limited to the repair of the product, or
replacement thereof, including parts, at the sole discretion of Elation
Professional®. All products covered by this warranty were manufactured after
January 1, 1990, and bare identifying marks to that effect. E. Elation
Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes
in any products theretofore manufactured. F. No warranty, whether expressed or
implied, is given or made with respect to any accessory supplied with the
products described above. Except to the extent prohibited by applicable law,
all implied warranties made by Elation Professional® in connection with this
product, including warranties of merchantability or fitness, are limited in
duration to the warranty periods set forth above. And no warranties, whether
expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s
and/or dealer’s sole remedy shall be such repair or replacement as is
expressly provided above; and under no circumstances shall Elation
Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this
product. G. This warranty is the only written warranty applicable to Elation
Professional® products and supersedes all prior warranties and written
descriptions of warranty terms and conditions heretofore published.
7
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
SAFETY INSTRUCTIONS
The SIXPAR 300IPTM is an extremely sophisticated piece of electronic
equipment. To guarantee a smooth operation, it is important to follow the
guidelines in this manual. The manufacturer of this device will not accept
responsibility for damages resulting from the misuse of this fixture due to
the disregard of the information printed in this manual. This device falls
under PROTECTION CLASS 1. It’s essential this device be grounded properly.
Only qualified personnel should perform all electrical connections.
CAUTIONS
UNPLUG POWER BEFORE SERVICING FIXTURE
NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE SENSITIVE PERSONS MAY SUFFER AN
EPILETIC SHOCK
· For proper operation, follow the Installation guidelines described in this
manual. Only qualified and certified personnel should perform installation of
this fixture and only the original rigging parts (brackets) included with this
fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal
injury.
· Never look directly into the light source of this fixture to prevent risk of
injury to your retina, which may induce blindness. Those suffering from E P I
L E P S Y should avoid looking directly into the light source of this unit at
all times.
· Always disconnect from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug end,
never pull out the plug by tugging the wire portion of the cord.
· Do not operate this fixture if the power cord has become frayed, crimped
and/or damaged. If the power cord is damaged, replace it immediately with a
new one of similar power rating.
8
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
GENERAL GUIDELINES
· NEVER OPEN THIS FIXTURE WHILE IN USE! · Ensure ALL connections and end caps
are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion
and/or electrical short circuit. · During the initial operation of this
fixture, a light smoke or smell may emit from the interior of the fixture.
This is a normal process and is caused by excess paint in the interior of the
casing burning off from the heat associated with the lamp and will decrease
gradually over time. · Please make sure there are NO FLAMMABLE MATERIALS close
to the fixture while operating, to prevent any fire hazard. · Minimum distance
of inflammable materials from the surface 1.6 feet (0.5m). · DO NOT attempt
installation and/or operation without knowledge how to do so. · DO NOT allow
operation by persons who are not qualified to operate this type of fixture.
Most damages are the result of operations by nonprofessionals. · Consistent
operational breaks may ensure the fixture will function properly for many
years to come. · DO NOT shake fixture, avoid brute force when installing
and/or operating fixture. · Always install the fixture with an appropriate
safety cable. When installing the fixture in a suspended environment, always
use mounting hardware that is no less than M10 x 25 mm, also be sure the
hardware is insert in the pre-arranged screw holes in the bracket of the
fixture. · Use the original packaging and materials to transport the fixture
in for service. · DO NOT TOUCH the housing bare-hand during its operation.
Turn OFF the power and allow approximately 15 minutes for the fixture to cool
down before replacing or serving.
9
SIXPAR 300IPTM User Manual ver 1
FIXTURE OVERVIEW
www.elationlighting.com
1. MODE Button 2. UP Button 3. DOWN Button 4. ENTER Button 5. Power IN 6. DMX IN 7. DMX Out 8. Power OUT
10
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) away from any flammable materials,
decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or
installations.
CAUTIONS
· For added protection, mount the fixture in areas outside walking paths,
seating areas, or in areas were unauthorized personnel might reach the
fixture.
· Min/Max ambient operating temperature for this fixture is 5°F to 113°F
(-15°C to 45°C). Do not use the fixture under or above this temperature.
· Before mounting the fixture to any surface, make sure the installation area
can hold a minimum point load of 10 times the weight of the fixture. 210 lbs /
95 kg)
· Fixture installation must always be secured with a secondary safety
attachment, such as an appropriate safety cable.
· Never stand directly below the device when mounting, removing or servicing.
· Ensure ALL connections and end caps are properly sealed with a dielectric
grease (available at most electrical suppliers) to prevent water corrosion
and/or electrical short circuit. POWER LINKING Max number of units that can be
power linked is 5 units @110V and 10 units @240V.
CLAMP MOUNTING The SIXPAR 300IPTM provides a unique integrated Dual Yoke /
Floor Stand. When mounting this fixture to truss be sure to secure an
appropriately rated clamp using an M10 screw fitted through the center hole of
the Dual Yoke / Floor Stand.
11
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
SECURING Regardless of the rigging option you choose for your SIXPAR 300IPTM
always be sure to secure your fixture with a safety cable.
MOUNTING POINTS · Overhead mounting requires extensive experience, including
amongst others
calculating working load limits, installation material being used, and
periodic safety inspection of all installation material and the device. If you
lack these qualifications, do not attempt the installation yourself. Improper
installation can result in bodily injury. · Fixture is fully operational in
the specific mounting positions as illustrated below.
SAFETY CABLE
Always use a Safety Cable whenever installing this fixture in a suspended
environment to ensure the fixture will not drop if the clamp fails.
12
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
UNDERSTANDING DMX
DMX-512 DMX is short for Digital Multiplex. This is a universal protocol used
by most lighting and controller manufactures as a form of communication
between intelligent fixtures and controllers. DMX allows all makes and models
of different manufactures to be linked together and operate from a single
controller. This is possible as long as all the fixtures and the controller
are DMX compliant. A DMX controller sends the DMX data instructions to the
fixture allowing the user to control the different aspects of an intelligent
light. DMX data is sent out as serial data that travels from fixture to
fixture via data “IN” and data “OUT” XLR terminals located on the fixtures
(most controllers will only have output jacks).
DMX LINKING To ensure proper DMX data transmission, always use the SIXPARTM
series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the
end of this manual. When using several DMX fixtures try to use the shortest
cable path possible. Never split a DMX line with a “Y” style connector. The
order in which the fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a starting DMX address of 1
may be placed anywhere in the DMX chain, at the beginning, at the end, or
anywhere in the middle. The DMX controller knows to send data assigned to
address 1 to that fixture no matter where it is located in the DMX chain. The
SIXPAR 300IPTM can be controlled via DMX-512 protocol and the DMX address is
set via the control menu.
DATA CABLE (DMX Cable) REQUIREMENTS (For DMX and Master/Slave Operation) Your
fixture and your DMX controller require a standard 3pin or 5pin XLR connector
for data input and data output (see figure below). Also, remember that a DMX
line must be daisy chained and cannot be split.
13
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
DMX-512 CONTROLLER CONNECTION Connect the provided XLR cable to the female XLR
output of your controller and the other side to the male XLR input of the
SIXPAR 300IPTM. The diagram below illustrates a typical DMX-512 connection
when the fixture is in the 12 Channel Mode. You can chain multiple panels
together through serial linking. Always be sure daisy chain your in and out
data connections, never split or “Y” your DMX connections.
DMX CONTROLLER
Address 1
Address 13
Address 25
DMX-512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs. The use of a terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a line terminator will decrease the possibilities of erratic behavior. Use the SIXPARTM DMX Terminator End Cap listed in the OPTIONAL ACCESSORIES section at the end of this manual.
14
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
DMX ADDRESSING All fixtures should be given a DMX starting address when using
a DMX controller, so the correct fixture responds to the correct control
signal. This digital starting address is the channel number from which the
fixture starts to “listen” to the digital control information sent out from
the DMX controller. The allocation of this starting DMX address is achieved by
setting the correct DMX address on the digital display located on the back of
the fixture.
You can set the same starting address for all fixtures or a group of fixtures,
or set different address for each individual fixture. Be advised that setting
all fixtures to the same DMX address will subsequently control all fixtures in
the same fashion, in other words, changing the settings of one channel will
affect all the fixtures simultaneously.
If you set each fixture to a different DMX address, each unit will start to
“listen” to the channel number you have set, based on the quantity of control
channels (DMX channels) of each fixture. That means changing the settings of
one channel will only affect the selected fixture.
In the case of the SIXPAR 300IPTM, when in the 12 Channel Mode you should set
the starting DMX address of the first unit to 1, the second unit to 13 (1 +
12), the third unit to 25 (13 + 12), and so on.
Note: During start-up the SIXPAR 300IPTM will automatically detect whether a
DMX data signal is being received or not. If the fixture is not receiving a
DMX signal please check the following:
– The 3pin or 5pin XLR input plug (cable with DMX signal from controller) is
not connected or is not inserted completely into the DMX input jack of the
fixture.
– The DMX controller is switched off or defective. – The DMX cable or
connector is defective. – A DMX terminator has been inserted into the last
fixture in your DMX chain.
15
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
FIXTURE MENU
ON-BOARD SYSTEM MENU
The SIXPAR 300IPTM comes with an easy to navigate system menu. The next
sections will cover how to access each menu function.
LCD CONTROL PANEL DISPLAY
The (4) button control panel (see image below) located on back of the fixture
allows you to access the main menu and make all necessary adjustments to the
SIXPAR 300IPTM. During normal operation, pressing the MODE button will
navigate through the different function menus. Once you reach a desired menu,
press the ENTER button to select that menu. The variable field that can be
adjusted within the selected menu will begin to flash. Using the UP or DOWN
buttons, adjust the field until the desired value is displayed. For example,
the CHANNEL CH: menu variable field can be set to 06, 07, 08, or 12. Pressing
the ENTER button once will confirm your selected value. Exit at any time
without making any adjustments by pressing the MODE button.
INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON, the display shows the following information:
Update Wait…
SIXPAR 300IP
300IP V1.03
Fixture Software Version (Greater than or equal to)
16
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
LCD CONTROL PANEL LOCKOUT When the Display ON menu is set to OFF1, the LCD
display will turn OFF after 30 seconds and the (4) button Control Panel will
be LOCKED. To unlock the (4) button LCD control panel follow these steps:
1. When locked, the display will show: LOCKED* 2. Press UP, then the
display will change to: LOCKED** (one * disappears) 3. Press DOWN, then the
display will change to: LOCKED** (two disappear) 4. Press UP, then the
display will change to: LOCKED (three disappear) 5. Press DOWN, then the
display will change to: LOCKED (4 * disappear) 6. Press ENTER, then the
display will change to LOCKED and then become unlocked.
MENU CHANNEL DMX MODE SLAVE MODE Display ON
Internal Programs
DimCurve NO DMX
ELATION© SIXPAR 300 IPTM
SYSTEM MENU
Specifications are subject to change without any prior written notice.
OPTIONS / VALUES
DESCRIPTION
CH: 06, 07, 08, 12
DMX Channel Mode
ADDR: 001 ~ 512
DMX Address Setting
SALVE MODE
Set Fixture A Slave Unit
ON
LCD Display Always ON
OFF
LCD Display OFF after 30 seconds
OFF1
LCD Display OFF After 30 Seconds and LOCKED
1.MANUAL
Manual Color Adjustment
R00-99
Adjust RED Brightness (00-99)
G00-99
Adjust GREEN Brightness (00-99)
B00-99
Adjust BLUE Brightness (00-99)
W00-99
Adjust WHITE Brightness (00-99)
A00-99
Adjust AMBER Brightness (00-99)
U00-99
Adjust UV Brightness (00-99)
S00-99
Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
2.CHANGE
30 Color Chase Macro
SP01-99
Adjust SPEED 01 SLOW – 99 FAST
S00-99
Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
3.CHANG6
6 Color Chase Macro
SP01-99
Adjust SPEED 01 SLOW – 99 FAST
S00-99
Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
4.FADE
Color Fade Macro
SP01-99
Adjust SPEED 01 SLOW – 99 FAST
S00-99
Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
Standard, Stage, TV, Architec, Theatre
Set Dimming Curve
Blackout
NO Output
Hold
Hold Last Setting
Fade
Fade
17
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com DIMMING CURVES The DimCurve menu allows you to select
one of the following preset dimming curves: Standard, Stage, TV, Architec, or
Theatre. (See diagram below for more details)
Dimmer
18
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
DMX CHANNEL FUNCTIONS AND VALUES
ELATION© SIXPAR 300IPTM
DMX Channel Values / Functions (12 DMX Channels)
Specifications are subject to change without any prior written notice.
MODE / CHANNEL 6 CH 7 CH 8 CH 12 CH
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
6
7
7
7
8
8
VALUE
FUNCTION
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-31 32-95 96-127 128-159 160-191 192-223 224-255
RED Red (0-100%) GREEN Green (0-100%) BLUE Blue (0-100%) WHITE White (0-100%)
AMBER
Amber (0-100%) U. V. U. V. (0-100%) MASTER DIMMER Dimmer (0-100%) STROBE LED
OFF (NO STROBE) Strobe Effect SLOW to FAST LED ON (NO STROBE) Strobe Pulse
Effect In Sequences SLOW to FAST LED ON (NO STROBE) Random Strobe Effect SLOW
to FAST LED ON (NO STROBE)
19
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
6 CH
ELATION© SIXPAR 300IPTM
DMX Channel Values / Functions (12 DMX Channels)
Specifications are subject to change without any prior written notice.
MODE / CHANNEL
VALUE
FUNCTION
7 CH
8 CH
12 CH
COLOR MACROS
0-3
OFF
4-7
RED
8-11
GREEN
12-15
BLUE
16-19
WHITE
20-23
AMBER
24-27
UV
28-31
RED + GREEN
32-35
RED + BLUE
36-39
RED + WHITE
40-43
RED + AMBER
44-47
RED + UV
48-51
GREEN + BLUE
52-55
GREEN + WHITE
56-59
GREEN + AMBER
60-63
GREEN + UV
64-67
BLUE + WHITE
68-71
BLUE + AMBER
9
72-75
BLUE + UV
76-79
WHITE + AMBER
80-83
WHITE + UV
84-87
AMBER + UV
88-91
RED + GREEN + BLUE
92-95
RED + GREEN + WHITE
96-99
RED + GREEN + AMBER
100-103
RED + GREEN + UV
104-107
RED + BLUE + WHITE
108-111
RED + BLUE + AMBER
112-115
RED + BLUE + UV
116-119
RED + WHITE + AMBER
120-123
RED + WHITE + UV
124-127
RED + AMBER + UV
128-131
GREEN + BLUE + WHITE
132-135
GREEN + BLUE + AMBER
136-139
GREEN + BLUE + UV
140-143
GREEN + WHITE + AMBER
144-147
GREEN + WHITE + UV
148-151
GREEN + AMBER + UV
20
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
ELATION© SIXPAR 300IPTM
DMX Channel Values / Functions (12 DMX Channels)
Specifications are subject to change without any prior written notice.
MODE / CHANNEL
VALUE
FUNCTION
6 CH 7 CH 8 CH 12 CH
COLOR MACROS (continued)
152-155 BLUE + WHITE + AMBER
156-159 BLUE + WHITE + UV
160-163 BLUE + AMBER + UV
164-167 WHITE + AMBER + UV
168-171 RED + GREEN + BLUE + WHITE
172-175 RED + GREEN + BLUE + AMBER
176-179 RED + GREEN + BLUE + UV
180-183 RED + GREEN +WHITE + AMBER
184-187 RED + GREEN + WHITE + UV
188-191 RED + GREEN + AMBER + UV
192-195 RED + BLUE + WHITE + AMBER
196-199 RED + BLUE + WHITE + UV
9
200-203 RED + BLUE + AMBER + UV
204-207 RED + WHITE + AMBER + UV
208-211 GREEN + BLUE + WHITE + AMBER
212-215 GREEN + BLUE + WHITE + UV
216-219 GREEN + BLUE + AMBER + UV
220-223 GREEN + WHITE + AMBER + UV
224-227 BLUE + WHITE + AMBER + UV
228-231 RED + GREEN + BLUE + WHITE + AMBER
232-235 RED + GREEN + BLUE + WHITE + UV
236-239 RED + GREEN + BLUE + AMBER + UV
240-243 RED + GREEN + WHITE + AMBER + UV
244-247 RED + BLUE + WHITE + AMBER + UV
248-251 GREEN +BLUE + WHITE + AMBER + UV
252-255 RED + GREEN + BLUE + WHITE + AMBER + UV
COLOR CHASE MACROS
00-20 NO Function
21-40 30 Color Chase 10
41-60 6 Color Chase
61-80 Color Fade Chase
81-255 NO Function
COLOR CHASE MACROS SPEED 11
00-255 Chase Speed of CHANNEL 10 – SLOW to FAST
DIMMING MODES
0-20
STANDARD
21-40 STAGE
12
41-60 TV
61-80 ARCHITECTURAL
81-100 THEATER
101-255 NO Function
21
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
CLEANING AND MAINTENANCE
C
A
U
T
I
O
N
Disconnect power before cleaning or maintenance.
CLEANING Frequent cleaning is recommended to insure proper function, optimized
light output, and an extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
environments can cause greater accumulation of dirt on the fixture’s optics. ·
Clean the external lens surface at least every 20 days with a soft cloth to
avoid
dirt/debris accumulation. Never use alcohol, solvents, or ammonia based
cleaners.
MAINTENANCE Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
Please refer to the following points during routine inspections: · A detailed
electric check by an approved electrical engineer every 3 months, to
make sure the circuit contacts are in good condition and prevent overheating.
· Be sure all screws and fasteners are securely tightened at all times. Lose
screws
may fall out during normal operation resulting in damage or injury. · Check
for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing
could allow for dust to enter into the fixture. Damaged rigging points or
unsecured rigging could cause the fixture to fall and seriously injure a
person(s). · Inspect all moving parts and make sure there are no signs of wear
and rotate/move without imbalances. · Electric power supply cables must not
show any damage, material fatigue or sediments. Never remove the ground prong
from the power cable.
22
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
TECHNICAL SPECIFICATIONS
FEATURES IP65 Rated 15° Beam 25° Field Angles 5 Variable Dimming Curve Modes
Dual Yoke / Floor Stand Multiple Unit Power Linking RDM – Remote Device
Management Rugged Die-Cast Aluminum Exterior Flicker Free Operation for TV and
FILM
SOURCE (18) 12W 6-in-1 RGBAW+UV LEDs 100,000 Hour Average LED Life
EFFECTS Electronic Strobe Color and Chase Macros Electronic Dimming: 0% – 100%
5 Variable Dimming Curve Modes
CONTROL / CONNECTIONS (4) DMX Channel Modes (6 / 7 / 8 / 12) (4) Button Touch
Control Panel LCD Menu Display IP DMX and Power In/Out
SIZE / WEIGHT Length: 14.4″ (365mm) Width: 6.2″ (157mm) Vertical Height: 14.4″
(365mm) Weight: 21.6 lbs. (9.5 kg)
ELECTRICAL / THERMAL AC 110-250V – 50/60Hz 220W Max Power Consumption Power
Linking: 5pcs @110V / 10pcs @240V 5°F to 113°F (-15°C to 45°C)
APPROVALS / RATINGS CE | IP65**
**Optional Corrosion-Resistant Coating may be available for this fixture. Please consult an Elation sales representative for details. Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
23
SIXPAR 300IPTM User Manual ver 1
PHOTOMETRIC DATA
www.elationlighting.com
DIMENSIONAL DRAWINGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
24
SIXPAR 300IPTM User Manual ver 1
www.elationlighting.com
OPTIONAL ACCESSORIES
ORDER CODE
ITEM
TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp
SIXPAR300/GFH
Gel Frame and Holder Kit
SIXPAR/BD300
Barn Door (Gel Frame Holder Kit Required – Not Included)
EWD001
EWDMX IP Wireless IP65 DMX Transceiver
SIXPAR/2MDLC
6.6 ft. (2m) IP Data Link Cable
SIXPAR/2MPLC
6.6 ft. (2m) IP Power Link Cable
SIXPAR/3MDLC
9.8 ft. (3m) IP Data Link Cable
SIXPAR/3MPLC
9.8 ft. (3m) IP Power Link Cable
SIXPAR/5MDLC
SPECIAL ORDER ITEM 16.4 ft. (5m) IP Data Link Cable
SIXPAR/5MPLC
SPECIAL ORDER ITEM 16.4 ft. (5m) IP Power Link Cable
SIXPAR/10MDLC SPECIAL ORDER ITEM 32.8 ft. (10m) IP Data Link Cable
SIXPAR/10MPLC
SPECIAL ORDER ITEM 32.8 ft. (10m) IP Power Link Cable
SIXPAR/20MDLC SPECIAL ORDER ITEM 65.6 ft. (20m) IP Data Link Cable
SIXPAR/20MPLC
SPECIAL ORDER ITEM 65.6 ft. (20m) IP Power Link Cable
SIXPAR/DIAC
Data IN IP Adapter Cable
SIXPAR/DOAC
Data OUT IP Adapter Cable
SIXPAR/PIAC
Power IN IP Adapter Cable
SIXPAR/POAC
Power OUT Adapter Cable
SIXPAR/TERMINATOR DMX Terminator End Cap
25
SIXPAR 300IPTM User Manual ver 1
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>