ISTA BREEZE 4KW 48V Charge Controller Instructions
- June 13, 2024
- iSTA BREEZE
Table of Contents
ISTA BREEZE 4KW 48V Charge Controller Instructions
4Kw 48v is new generation Charge Controller. This device is not hybrid but it
can be integrated into hybrid system, (important thing is suitable battery and
suitable system).
Solar charger and Wind charger can be connect parallel into same battery
group.
The high-end device can also be used as a monitoring system. It is used to safely and efficiently charge and control your battery with the Wind Generator.
With its discreet appearance, simple operation, with integrated protection functions, this device has high efficiency and low no-load losses. This version of the controller will significantly increase the life and stability of the whole system, especially the batteries
In addition, the control electronics in the control cabinet monitors the system voltage and brakes the wind turbine when a max. Overvoltage
The special features and product information are listed below:
Use of external and high quality (Triacs), solid state components. Increasing thelife of the controller
Microprocessor controlled charge with integrated voltage and current limiting. Electromagnetic brake control.Integrated 3-phase short circuit breakers (brake switch)
Protection against lightning strikes. Protection against overcharging, deep discharge, short circuit, overload.
Integrated display.
The generator is automatically braked gently when the battery is full, modern braking system with external load resistance (Dump Load) to avoid the immediate blocking of the turbine. Increasing the life of the stator.
Parts Descriptions
Reset Button:
This button deactives when generator was on automatic brake
Manuel Brake Button:
- For manual brake, please press “off”mode
- For operation, please press “on” mode
Generator On/Off Switch:
After generator stop (after manuel brake), please press mode 1 (off), and
generator is locked. (Safe braking is achieved in this way)
For active operation, please press mode 0 (on) and then close manual brake button
Lcd Display:
Amper, Watt, Battery Voltage, Brake, Temperature
Diagram
4KW 48V CHARGE CONTROLLER
Nominal Battery Voltage | 48VDC |
---|---|
Max Input Power Wind Turbine | 4 Kw |
Lcd with Display | Amper, Watt, Battery Voltage, Brake, |
Temperature
Charging voltage| 52,8 v
Charging Current Wind Amperes Max| 70 A
Generator On / Off Switch| After generator stop (after manual brake) please
press mode 1 (off) , and generator is locked. (Safe braking is achieved in
this wayFor active operation, please press mode 0 (on) and then close manual
brake button
Manual Brake Button| 1- For manual brake,please press “off” mode2- For
operation, please press “on” mode
Reset Button| This button deactives when generator was on automatic brake
Battery voltage Min| 42 V
Automatic Brake for Wind Turbine (Over heating )| 50 °C breaking / 45°C break
out
Wind Turbine Stop Charging Voltage| 58 V -+1
Wind Turbine Recharge Voltage| 55 V -+1
Cooling| External aluminium cooling fins
Cable Termination| Battery (16mm) – Wind Turbine and dump load
(10mm)- Ground (6mm)
Protection Class| IP 20 (inside area)
Dump Load| 4Kw Braking resistor (The load resistance can
deviate from Picture)
Operational Temperature| Normal: 20– + 55 °C / 35–85%RH Industrial : 30″ + 55
°C / 35–85%RH
Temperature Conpensation| -4Mv°C/2V,-35°C -+80°C , Accuracy +-1°C
Size| 304020 cm
Weight| 12 kg
Recommended Battery Min| Acid &Gel (It can be redesign according to Lithium
batteries