Labkotec GA-1 Grease Alarm Device User Guide
- June 12, 2024
- Labkotec
Table of Contents
Measures for a batter tomorrow
Communication Unit
Labcom 220
Warning Device GA-1
DOC001417
Quick Guide
Application example
Please take note
This Quick Guide describes an application example for the communication
unit Labcom 220 and the warning device GA-1. It is not substituting the
instruction manuals for Labcom 220 and GA-1.
Safety instructions, intended use and detailed information of the two devices
are described in each of the corresponding instruction manuals.
Requirements
The Labcom 220 communication unit as well as the GA-1 warning device must be
installed in accordance with the respective instruction manual.
The cable connection between the two devices matches the application example.
The PIN code for the SIM card of the Labcom 220 communication unit must be
disabled. This can be done by means of a mobile phone. Follow the instructions
provided in the mobile phone’s manual to do this.
The application example shows the scheme of the GA-1 warning device, where the
relay switches upon grease alarm, sensor cable breakage or sen-sor defect. The
relay of the warning device switches back as soon as the sensor is no longer
in the alarm state.
Inserting the SIM card
SMS parameter steps and examples
Please take note
The SMS command must use the uppercase and must end with a blank space.
Multiple entries must be separated by a blank space. Mobile phone numbers must
always use the plus sign followed by the country code. SMS text input are
always confirmed with a reply SMS by the Labcom 220 communication unit. If no
confirmation or notification arrives, check the credit balance of the SIM card
or the contract term of your mobile service provider. Parameter setting for
one or multiple user mobile phone numbers Parameter setting for device or
system name Parameter setting for current date and time Parameter
setting for digital input Parameter setting for cyclic status
notification
**** Labkotec Oy reserves the right to make changes at any time and without prior notice. Technical specifications may change at any time because of ongoing improvements done by our Depart-ment of Research and Development. The instal-lation must always be carried out in accordance with the instructions of the manufacturer.
Measures for a batter tomorrow Labkotec Oy
Myllyhaantie 6
FI-33960 Pirkkala
FINLAND
+358 (0)29 006 260
info@labkotec.fi
Labkotec GmbH
info@labkotec.de
Labkotec Sweden
info@labkotec.se
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>