HINKLEY 13200BU Ryden LED Outdoor Wall Mount Instruction Manual
- June 12, 2024
- HINKLEY
Table of Contents
- HINKLEY 13200BU Ryden LED Outdoor Wall Mount
- Product Information
- Product Usage Instructions
- ASSEMBLY INSTRUCTION
- SAFETY WARNING
- I.S. 18 wiring grounding instructions
- wiring instructions
- IS200 Caulking Instructions
- ABOUT COMPANY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HINKLEY 13200BU Ryden LED Outdoor Wall Mount
Product Information
- Product Name: HINKLEY
- Item No: 13204-13200
- Manufacturer: HINKLEY
- Address: 33000 Pin Oak Parkway, Avon Lake, OH 44012
- Contact: 800.446.5539 / 440.653.5500
- Website: hinkley.com
Product Usage Instructions
Mounting Instructions:
- Find a clear area in which you can work.
- Secure threaded rod (B) to mounting strap (A).
- Thread on one hex nut (F) onto the threaded rod (B).
- Thread on the other two hex nuts (F) onto the threaded rod (B) on the other side of the mounting strap (A) – Drawing 1.
- Secure mounting strap (A) to junction box (J) using screws (C).
- Make wiring connections using IS-18.
- Use knob (D) to secure backplate (E) to threaded rod (B).
- Glass can now be installed.
Electrical Connections:
- Indoor Fixtures:
1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist-on connector – see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Refer to the grounding instructions below to complete all electrical connections.
- Outdoor Fixtures:
1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist-on connector – see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
4. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
Safety Warning:
Read wiring and grounding instructions (I.S. 18) and any additional
directions. Turn power supply off during installation. If new wiring is
required, consult a qualified electrician or local authorities for code
requirements.
ASSEMBLY INSTRUCTION
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
- Secure threaded rod (B) to mounting strap (A)
- Thread on one hex nut (F) onto the threaded rod (B)
- Thread on the other two hex nuts (F) onto the threaded rod (B) on the other side of the mounting strap (A) – Drawing 1
- Secure mounting strap (A) to junction box (J) using screws (C)
- Make wiring connections using IS-18
- Use knob (D) to secure backplate (E) to threaded rod (B)
- Glass can now be installed
SAFETY WARNING
READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS. Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete installation of this fixture.
- Lamp fixture using appropriate medium base bulb (G)
- Place glass (F) over bulb (G)
- Secure glass ring (K) using knobs (L)
- Fixture can now be powered on
I.S. 18 wiring grounding instructions
SAFE TY WARNI NG: READ WIRIN G AND GROUNDING INSTRUCTIO NS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A ) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Dra w ings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conduc tor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
-
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M ) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw. -
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2. -
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.
IS200 Caulking Instructions
-
After securing fixture to the wall it is recommended that the gap between the wall and the fixture backplate be sealed on the top and both sides, with a good quality waterproof caulk or silicone sealant (NOT INCLUDED) – see Drawing 1.
-
After securing fixture in place it is recommended that the gap between the mounting top and fixture base be seal ed with any good quality waterproof caulk or silicone sealant (not incl uded). It is also recomm ended that a small bead of caulk or sealant be put under the ball kn obs used to mount fixture – see Drawing 2.