  • The Sunstone Side Burner is an outdoor cooking gas appliance that conforms to ANSI STD Z21.58-2018 and is certified to CSA STD 1.6-2018. It is designed for easy installation and operation, providing optimum performance and longevity.
  • Sunstone Metal Products LLC is the manufacturer of this side burner. They are located at 16004 Central Commerce Dr, Pflugerville, Texas 78660. Their business hours are from Monday to Thursday, 9:00AM to 4:30PM. You can contact their Customer Service Department at (888)-934-9449 or email [email protected] for warranty service or technical support.

Product Usage Instructions

  1. Before operating the Side Burner, read all the instructions
    provided in the manual carefully. Ensure that the Side Burner is installed according to the installation guide. Failure to follow the basic setup instructions may void the warranties.

  2. Keep this manual for future reference.

  3. Make sure there is gas supplied to the Side Burner and check if the LP Tank has been recently refilled.

  4. Prior to contacting customer service, gather the following information:

    • Model Number
    • Date of Purchase
    • Invoice Number
  5. For warranty service, contact SUNSTONE Customer Service Department at (888)-934-9449 or email [email protected].

  6. Never operate the burner unattended. Always be present while using it.

To installer or person assembling burner: Leave this manual with burner for future reference.
To consumer: Keep this manual for future reference. www.sunstonemetalproducts.com
ATTENTION: THE SIDE BURNER MUST BE INSTALLED ACCORDING TO THE INSTALLATION GUIDE. IF YOUR SIDE BURNER INSTALLATION DOES NOT MEET THE BASIC SETUP INSTRUCTIONS ALL WARRANTIES MAY BE VOID. SEE WARRANTY ON LAST PAGE.

Welcome & Congratulations

Congratulations on your purchase of a new Sunstone Side Burner! We are very proud of our product and we are completely committed to providing you with the best service possible. Your satisfaction is our #1 priority. Please read this manual carefully to understand all the instructions about how to install, operate and maintain for optimum performance and longevity. We know you’ll enjoy your new burner and thank you for choosing our product. We hope you consider us for future purchases.

How to Obtain Service

  • Before you call
  • Is there Gas supplied to the Side Burner?
  • Have you recently refilled the LP Tank?
  • Please make sure you have the following information:
  • MODEL NUMBER | DATE OF PURCHASE| INVOICE NUMBER.
  • KEEP A COPY OF THE PRODUCTS ITEMIZED INVOICE FOR YOUR RECORDS
  • For warranty service, contact SUNSTONE Customer Service Department at (888)-934-9449 or email [email protected].

ABOUT COMPANY

  • SUNSTONE METAL PRODUCTS LLC.
  • 16004 Central Commerce Dr, Pflugerville Texas 78660.
  • Business Hours.
  • Mon. to Thur. 9:00AM to 4:30PM
  • Closed Fri/Sat/Sun
  • Tel: 512-487-5116
  • Toll Free: 888-934-9449 (Technical Support Line)
  • Fax: 512-487-7016

SAFETY INSTRUCTION

  • ATTENTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury, or property damage.
  • WARNING: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • VOLTAGE: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate electrical shock.
  • EXPLOSION: Indicates an imminently hazardous situation which, if not avoided, will result in possible explosion and cause death or serious injury.
  • BODILY INJURY: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury, or property damage.
  • HOT SURFACE: Indicates an imminently hazardous hot surface which, if not avoided, will result in serious burn or injury.
  • LIVE CIRCUIT: Indicates a potentially hazard from Live electrical current that if extreme caution is not used, may result in minor or moderate personal injury, or property damage.

START-UP CHECKLIST

Caution: Never operate the burner unattended.

FIRST TIME STARTUP CHECKLIST

  • The burner is free of any debris or obstruction.
  • Installation of the proper gas type and regulator settings.
  • The proper gas connection is complete.
  • Minimum clearances are maintained.
  • All packaging has been removed.
  • All parts and components are properly installed.
  • An installer-supplied manual gas shut-off valve is fully accessible.
  • LP hose is clean and inspected for cuts, wear, abrasions, or leaks.
    Replace if necessary, with a suitable UL, ETL or CSA Listed part with internally threaded connector.

SPECIFICATIONS

Diagram 1SSB

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-3

No. Name Qty Part No.
1 1SSB Hood 1 SB-HOOD
2 Hood Handle 1 P-HANDLE
3 Grate Grids 1 BURNER-GRAT
4 Burner Assembly 1 BURNER-RING
5 Impulse Igniter 1 IMP-IGNITER
6 Gas Chamber 1 BURNER-GC
7 1SSB Gas Manifold 1 SB-MANIFOLD
8 1SSB Valve 1 SB-VALVE LP/NG
9 Igniter Ring 1 IG-RING
10 Control Knob 1 KNOB-L
11 Control Knob Ring 1 KNOB-RING
12 Igniter Box Cab 1 IG-CAP
13 1SSB Igniter Box 1 IG-BOX
14 1SSB Base 1 SB-BASE

Diagram 2CSB

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-4

No. Name Qty Part No.
1 2CSB Hood 1 DB-HOOD
2 Hood Handle 1 P-HANDLE
3 Hood Brackets 2 DB-HOOD-BRK
4 Base Brackets 2 DB-BASE-BRK
5 Grate Grids 2 BURNER-GRAT
6 Gas Chamber 2 BURNER-GC
7 Impulse Igniter 2 IMP-IGNITER
8 2CSB Gas Manifold 1 SB-VALVE LP/NG
9 Igniter Ring 1 IG-RING
10 2CSB Valve 2 DB-VALVE LP/NG
11 Control Knob Ring 2 KNOB-RING
12 Large Knobs 2 KNOB-L
13 Igniter Box Cap 1 IG-CAP
14 2CSB Igniter Box 1 IG-BOX
15 2CSB Control Panel 1 DB-CT-PAN
16 2CSB Base 1 DB-BASE

LOCATING BURNER

INSTALLATION REQUIRMENTS

  1. COMBUSTABLE MATERIALS: For Wood Framed Island Construction it is Extremely important Not to use any wood within 24″ of Side Burner. Wood frame is fine for Bar/Sink areas and or Storage compartments. If your island is mostly wood, just substitute for Metal Studs while within the 24″ of Side Burner. If the island structure is against any Combustible Materials – be sure to provide protection and keep a minimum distance of 12″ away.
  2. ISLAND VENTILATION: For every Gas-Related appliance Grill or Side Burner you are required to have at least Two Air-Vents in the Island, within 24″ of Appliance. Place Two Vents in Low position within 6″ from base on exterior wall when using Liquid Propane and place Two Vents in High position within 6″ below the counters bottom edge for Natural Gas. Do not Build Enclosure under Side Burners, Side burners are meant to Free-Hang from counter top surface.
  3. GAS SAFETY & ACCESS: For either Natural Gas or Liquid Propane type, it is required you have clear access to all interior island Gas-Plumbing, we recommend placing one of Sunstone’s Single Access Vented Doors. Also have at least One Safety-Shut Off Valve Present and within easy access, if this appliance is being installed in a High-Traffic location like for Residential Community, it is important to have installed a Shut-Off Timer set for Auto-Shut off in 20 Minutes.

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-5

Burner Cut-Out
Your Side Burner is SELF-RIMMING, meaning the lip of burner rests on top of the counter edge around the cut-out and is Free-Hanging from counter top. Because of this, there is No Need for any Trim-Kit unlike other side burners in the market.

  1. Maintain 24” Clearance from any Combustible Materials in ANY direction of burner.
  2. If any combustible materials within 24” distance, must have Heat Barrier like Jacket, or other Non-Combustible type like Bricks, Hardy Board, Metal.
  3. Orient the burner so the Prevailing winds are not blowing into the burner, this causes flame disbursement and can extinguish the flame.
    WARNING: Never build shelf or enclose interior space under the BBQ Cut- Out. The Side Burner is Self-Rimming and is supported by the top counter surface on the Back and Sides, the front of burner is designed to Free-Hang. The bottom of Burner needs to be open to allow for proper ventilation.

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-6

Ruby Series Burner Island Cut-Out Dimensions

  ITEM NO. WIDTH DEPTH HEIGHT
2CSB – LP/NG 12” 20-1/4” 8”
1SSB – LP/NG 10” 16-1/8” 4”

Installing in Open Area
ATTENTION: Take special precaution when installing burner in open Breezy area, check the direction of Prevailing Wind, if back of burner is facing any oncoming wind or breeze, be sure to protect the back of burner and erect a partition wall.

Windy Area
Positioning your Side Burner in your backyard is more often thought of as how it is pleasing to the eye, but more important than this is how it functions correctly. Unlike an indoor appliance, your burner must combat many outside weather influences in all manner of weather-related instances, most severely is Wind.

  1. If wind or breeze is in the direction of back of burner, you must erect partition wall of 8” height. If this is not done, you must use burner with hood open or when the hood is closed stand near the area to burner and monitor if the burner overheats.
Installing Under Structure

Overhead Structure Definition:
Structure built above Appliance that is sometimes attached to the home’s exterior outside wall or roof and there is a Minimum of “Two” adjacent sides which are open to outside exposure.

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-18

Enclosed Island Definition:
Any Appliance that is installed into “Enclosed” structure with Two or more sides walled off, either into an outdoor home’s patio structure, against any home exterior wall or under any Eaves of the home.

*Clearances to Non-Combustible Construction:**
A minimum of 4” to 6” clearance from the back of the burner to non-combustible construction is required for the purpose of allowing the lid to open fully. It is desirable to allow at least 6” rear and side clearance to construction above the cooking surface for counter space.

Installing Under Structure

  • ATTENTION: All Gas Burner Installations MUST HAVE MINIMUM TWO AIR-FLOW VENTS, either in ELEVATED POSITION for Natural Gas or LOWERED POSITION for Liquid Propane. Your Warranty may be VOID if island does not meet basic setup requirements.
  • BODILY INJURY: Failure to maintain required clearances creates a fire hazard that may result in property damage or serious personal injury.

Clearances to Combustible Construction:**

  • Minimum of 24” from the sides and rear of burner must be maintained to adjacent vertical combustible construction, above the counter top level. You should take in account that there is a large volume of heat, and smoke that will exhaust from the rear of the burner. This may discolor or damage unprotected areas, do not install under unprotected combustible construction without using a fire safe ventilation system.
  • A 24” minimum clearance must be maintained under the counter top to combustible construction. The clearance can be modified by a use of an insulated jacket.

** DEFINITION OF COMBUSTIBLE MATERIAL – Any materials of a building structure or decorative structure made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that are capable of transferring heat or being ignited and burned. Such material shall be considered combustible even though flame-proofed, fire-retardant treated, surface-painted, or plastered.
WARNING: NEVER BUILD YOUR OUTDOOR KITCHEN ISLAND USING COMBUSTIBLE MATERIALS, MAINTAIN 24” DISTANCES FROM BURNER. USING A BURNER JACKET IS NOT A SURE BET TO PROTECT COMBUSTIBLE MATERIALS, NEITHER IS THE USE OF HARDY-BOARD.

GAS INSTALLATION

Propane Tank Connections
IMPORTANT: Before connecting burner to gas source, make sure BBQ Burner control knobs are in “OFF”position. Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating label agrees with that of the supply.
All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. The installation of this appliance must conform with local codes or, in the absence of local codes, with either National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A 119.2/ NFPA 1192M, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.

LP Tank Removal, Transport and Storage

  • Turn OFF all control knobs and LP tank valve. Turn coupling nut counterclockwise by hand only -do not use tools to disconnect. Lift LP tank wire upward off LP tank collar, then lift LP tank up and off of support bracket. Install safety cap onto LP tank valve. Always use cap and strap supplied with valve. Failure to use safety cap as directed may result in serious personal injury and/or property damage.
  • A disconnected LP tank that is in storage or being transported must have a safety cap installed. Do not store an LP tank in enclosed spaces such as a carport, garage, porch, covered patio or other building. Never leave an LP tank inside a vehicle which may become overheated by the sun.

The cylinder must be arranged for vapor withdrawal. It must also include a collar to protect the cylinder valve. A safety relief device having direct communication with the vapor space of cylinder must be provided. This will expel high pressure gas if the cylinder is overfilled or overheated which could result in fire or explosion.

  • All LP gas cylinders used with this appliance shall be constructed and marked in accordance with the specifications for LP gas cylinders of the U. S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable; and shall be provided with a listed overfilling prevention device.
  • Read labels on the LP Gas Supply Cylinder.
  • New cylinders are always shipped empty for safety.
  • Allow only qualified LP gas dealers to fill or repair your LP gas supply cylinder.
  • Inform the gas dealer if it is a new or used cylinder to be filled.
  • After filling, have the gas dealer check for leaks and to see that the relief valve remains free to function.
    WARNING: If you have a Side Yard Propane Tank, you MUST have additional Medium Pressure Regulator located at the Burner. If you do not serious bodily harm may result or damage to the burner and island structure from HIGH Heat extremes.

Hose and Regulator
The Type 1 connection system has the following features:

  • The system will not allow gas to flow until a positive connection has been made.
    NOTE: The cylinder control valve must be turned off before any connection is made or removed.

  • The system has a thermal element that will shut off the flow of gas in the event of a fire.

  • The system has a flow limiting device which, when activated, will limit the flow of gas to 10 cubic feet per hour.

  • NEVER use burner without leak testing.
    Propane vapors are heavier than air. For this reason, they may accumulate in low-lying areas such as basements, crawl spaces, ditches, or along floors. However, air currents can sometimes carry propane vapors elsewhere within a building

LP (Propane) Gas Supply Connection & Disconnection

LP Tank Connection

  1. The tank valve should be in the “OFF” position. If not, turn the knob clockwise until it stops.
  2. Make sure all burner valves are in the “OFF” position.
  3. Always connect the gas supply regulator as follows: Insert the regulator inlet into the tank valve and turn the coupling nut clockwise until the coupler tightens up (see picture). Do not over tighten the coupler. Turn the main tank valve on and turn the burner control valves on the unit to the “HIGH”position for about 20 seconds to allow the air in the system to purge before attempting to light the burners.

LP Tank Disconnection

  1. Turn the burner valves off.
  2. Turn the tank valve off. (Turn clockwise to stop).
  3. Detach the regulator assembly from the tank valve by turning them quick coupling nut Counterclockwise.

Natural Gas Installation
Natural Gas Burners are designed to operate on Natural Gas ONLY, at a pressure regulated at 4” water column (W.C.) when equipped with the correct natural gas orifices on the valves and a NG regulator on the supply line regulated at the residential meter.

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-9

Natural Gas Supply Connection and Disconnection

  1. Make sure all burner valves are in the “OFF” position.
  2. To connect-push back sleeve of socket, insert Plug release sleeve. Push Plug until sleeve snaps forward locking Plug in Socket. (THIS TURNS GAS AUTOMATICALLY).
  3. To disconnect: Push sleeve back and pull out plug. (THIS AUTOMATICALLY SHUTS OFF GAS)
  4. Connected hose assembly shall be of adequate length and capacity for intended application. Final assembly must be tested for leaks.

Leak Test
WARNING: Always perform a leak test before lighting the burner to prevent a possible fire or explosion. Never store a spare propane cylinder in the vicinity of this Burner, or in the vicinity of any other potential heat source. Never attempt to attach this burner to the self-contained LP gas system. Do not use burner until leak testing.

  • Before Testing
    DO NOT smoke while leak testing. Extinguish all open flames. Never leak test with an open flame or risk of serious harm to self or others.

  • Mix Solution
    Prepare a leak testing solution of soapy water by mixing in a spray bottle one-part liquid soap to one-part water. You can also use mild detergent or liquid soap and water.

Leak Testing Procedure

  • Perform a leak test at least once a year whether the gas supply cylinder has been disconnected or not. In addition, whenever the gas cylinder is connected to the regulator or whenever any part of the gas system is disconnected or replaced, perform a leak test.
  • As a safety precaution, remember to always leak test your burner outdoors in a well-ventilated area. Never smoke or permit sources of ignition in the area while doing a leak test. Do not use a flame, such as a lighted match to test for leaks. Use a solution of soapy water.
    1. Make sure all the control knobs are in the OFF position.
    2. Turn on the gas.
    • On natural gas systems, turn the shut off valve to the burner.
    • On LP systems, turn the propane tank valve knob counter clockwise one turn to open.
    1. Apply the leak-testing solution by spraying it on joints of the gas delivery system. Blowing bubbles in the soap solution indicates that a leak is present.
    2. Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer. Do not attempt to repair the cylinder valve if it is damaged. The cylinder must be replaced.

Liquid Propane Leak Testing Procedure

  • Test connection from LP Tank to Regulator

  • Test connection from burner to LP Hose

Natural Gas Leak Testing Procedure

  • If unable to stop gas leak, turn gas off

  • Test connection next to NG regulator

  • Test connection from gas line to adapter

  • Test Quick Disconnect

BURNER STARTUP

Attention & Warnings

  • WARNING: When Lighting the Burner. DO NOT RELEASE KNOB, GAS WILL CONTINUE TO FLOW.
  • WARNING: Keep any electrical supply cords and the fuel supply hose away from any heated surfaces.
  • CAUTION: Inspect the hose before using the burner. If there is excessive abrasion or wear, or if the hose is cut, it must be replaced prior to the outdoor cooking gas appliance being put into operation. The replacement hose assembly shall be that specified by the manufacturer. Ensure the area around the barbecue is clear of flammable substances such as gasoline, yard debris, wood, etc. Ensure there is no blockage of the airflow through the vent space located below the face of the unit.
  • WARNING: OUTDOOR USE ONLY: NEVER operate burner in enclosed areas, as this could lead to gas accumulating from a leak, causing an explosion or a carbon monoxide buildup which could result in injury or death. NOT FOR USE BY CHILDREN. If these instructions are ignored, a hazardous fire or explosion could result in physical injury, death or property damage!
  • WARNING:
1. DO NOT Store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

CALIFORNIA PROPOSITION 65
WARNING: The burning of gas cooking fuels generates some byproducts which are on the list of substances which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these substances, always operate this unit according to the Use and Care Manual, ensuring you provide good ventilation when cooking with gas.

Burner Safety

  • For Household Outdoor Use Only – DO NOT use indoors or in any type of enclosed area such as a garage, shed or breezeway. Keep clear of trees and shrubs. The side burners are not intended for installation in or on recreational vehicles, portable trailers, boats or any other moving installation. Not for commercial use. The area surrounding your new side burner should be kept clean and free from flammable liquids and other combustible materials such as mops, rags or brooms, as well as solvents, cleaning fluids, and gasoline.
  • To reduce the risk of serious or fatal injury from breathing toxic fumes and from explosion and fire as a result of leaking gas, use only outdoors in an open area with good ventilation. Do not obstruct the flow of combustion and ventilation air. Never use the side burner in windy conditions. If located in a consistently windy area (oceanfront, mountaintop, etc.) a wind break will be required. Always adhere to the specified clearances listed.
  • Do not leave the side burner unattended while cooking. Do not use natural gas in a unit designed for liquid propane gas or vice versa. Do not use fuel such as charcoal briquettes on the side burner. Keep children and pets away from hot burner. DO NOT allow children to use or play near the side burner. Never attempt to repair or replace any part of the side burner yourself unless specifically recommended in this manual. All other services should be performed by a qualified service technician.
  • Never lean over an open burner. Do not place clothing or other flammable material on or near the burner. Do not wear loose-fitting clothes or long sleeves while using the side burner as some fabrics can be highly flammable. Have an ABC fire extinguisher accessible. Never attempt to extinguish a grease fire with water or other liquids. Never use aluminum foil on the burner grids, this can alter airflow for proper combustion and also build up heat in the control area causing the knobs and igniter to melt. When using the side burner, do not touch the burner grid or immediate surroundings as these areas become extremely hot and can cause burns. DO NOT allow grease or other hot material dripping from the burner onto valve, hose or regulator, turn off gas supply immediately. After the side burner has cooled, determine the cause and correct it. After cleaning the valve, hose and regulator, perform a leak test before continuing use. Do not heat any unopened glass or metal container of food on the side burner. Pressure may build up and cause the container to burst, possibly resulting in serious personal injury or damage to the side burner.
  • Keep any electrical supply cords away from water or heated surfaces. Electrical cords should be placed away from walkways to avoid tripping hazard. Keep gas supply lines as short as possible. Never move the side burner when hot. DO NOT use while under the influence of drugs or alcohol. DO NOT store a spare gas cylinder under or near your side burner. In the event that a burner goes out, turn burner knobs to the full OFF position. Do not attempt to use the side burner until the gas has had time to dissipate. Do not use side burner until leak check has been made. Turn off the cylinder valve when your side burner is not in use. Ensure the control knobs are in the “OFF” position when not in use.

Lighting Instructions

SUNSTONE-2CSB-LP-NG-Side-Burner-fig-17

NOTE: To light gas burner with a gas lighter, make sure the burner has been leak tested and burners are properly located. Insert long-necked gas lighter through the cooking grid placing near a burner side. Turn the closest burner knob on to “HIGH”setting to release gas. Turn on the button on gas lighter, burner should light immediately. Adjust burners to desired cooking temperature.

Care & Maintenance

ANNUAL CLEANING OF BURNER HOUSING
Burn-off the burner after use will keep it ready for instant use, however, once a year you should give the entire burner a thorough cleaning to keep it in top operating condition.

  1. Shut off gas supply at source and disconnect fuel line. Protect fuel line fitting.
  2. Remove and clean the cooking grids.
  3. Brush the inside and bottom of the burner with a stiff wire brush, and wash down with a mild soap.
  4. Check electrode.
  5. Reconnect to gas source and observe burner flame for correct operation.
    IMPORTANT: You should NOT line the bottom of the burner housing with aluminum foil, sand or any other grease absorbent substance. Grease will not be able to drip into the drip tray and a grease fire may occur.

MAINTENANCE GUIDELINES

  1. Keep outdoor cooking gas appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
  2. Do not obstruct the flow of combustion and ventilation of air flow.
  3. Keep the ventilation opening(s) of the cylinder enclosure free and clear from debris.
  4. Visually check burner flames. Burner flames should be blue and stable with no yellow tips, excessive noise, or lifting.
  5. Clean outdoor cooking gas appliance, including special surfaces, with recommended cleaning agents, if necessary.
  6. Check and clean burner for insects and insect nests. A clogged tube can lead to a fire beneath the burner.

RUST-BROWN MARKS:
When this type of staining occurs, it is unlikely that rusting of the stainless steel itself causes the marks. Similar marks can be found with both porcelain and plastic sinks. The rust marks are the result of small particles of “ordinary-steel”which have become attached to the surface; these have subsequently rusted in the damp environment. The most common source of such particles is from “wire wool” scouring pads, but contamination may also occur from carbon steel utensils and old cast iron water supply pipes. These brown marks are only superficial stains, which will not harm the Burner; they should be removable using a soft damp cloth and a multi-purpose cream cleanser. Occasionally, it may be necessary to resort to a proprietary stainless-steel cleanser, to return the surface of the Burner to its original condition. To avoid re-occurrence of any “rust-staining”it is essential that the source of the contamination be eliminated.

PITTING:
Another form of corrosion, which occasionally occurs in stainless steel, is pitting of the surface. The reason for this corrosive attack can usually be attributed to certain household products.

BLEACHES:
Most common domestic bleaches & sterilizing solutions contain chlorine in the form of sodium hypochlorite. If used in concentrated form, bleaches can attack the stainless steel, causing pitting of the surface. They should always be used to the strengths prescribed by the manufacturer and should be thoroughly rinsed off with clean water immediately after use. All cleaning agents containing hypochlorite are unsuitable for long term contact with stainless steel, even when used in the highly diluted form, they can give pitting under certain conditions.

FOODSTUFFS:
In general, stainless steel is fully resistant to all foodstuffs in common use. Only in isolated cases, such as when concentrated salt and vinegar mixtures remain in contact with the steel for long periods can any surface marking result.

SUNSTONE SIDE BURNER WARRANTY

“ALL WARRANTIES ARE VOID IF BURNER IS NOT INSTALLED ACCORDING TO SUNSTONE’S BASIC INSTALLATION GUIDELINES

WARRANTY ON PARTS

  • MAIN BURNERS: LIMITED LIFTIME
  • COOKING GRATES: LIMITED LIFETIME
  • FIREBOX & COMPONENTS: LIMITED LIFETIME
  • VALVES, KNOBS, LIGHTS & ALL OTHER PARTS: 1 YEAR WARRANTY

LIMITED LIFETIME WARRANTY
Brass burner, Cooking Grids, Stainless Steel Housings (including liners, frames, ovens and barbecue faces), to be free from defects in material and workmanship when subjected to normal domestic use and service for the lifetime of the original purchaser. This warranty does not include discoloration, surface corrosion, Burn Through and scratches which may occur during regular use.

LIMITED ONE-YEAR WARRANTY
All other burner components including knobs, valves, tubing, light assembly, and covers are warranted to be free from defects in material and workmanship for a period of one year from the original date of purchase. LIMITATIONS &

EXCLUSIONS

  1. SIDE BURNER warranty applies only to the original purchaser and may not be transferred.
  2. SIDE BURNER warranty is in lieu of all other warranties expressed or implied and all other obligations or liabilities related to the sale or use of its burner products.
  3. SIDE BURNER warranty shall not apply and SUNSTONE METAL PRODUCTS LLC. Is not responsible for damage resulting from misuse, abuse, alteration of or tampering with the appliance, accident, hostile environment, flare-up fires, improper installation, or installation not in accordance with the instructions contained in the User Manual, or the local codes.
  4. SUNSTONE METAL PRODUCTS LLC. shall not be liable for incidental, consequential, special or contingent damages resulting from its breach of this written warranty or any implied warranty.
  5. Some states do not allow limitations on how long an implied warranty lasts, or the exclusions of or limitations on Consequential damages. This warranty gives you specific legal rights and you may have other rights, which vary from state to state.
  6. No one has the authority to add to or vary SIDE BURNER warranty, or to create for SUNSTONE METAL PRODUCTS LLC. any other obligation or liability in connection with the sale or use of its products.

WHAT IS NOT COVERED & INTERNET PURCHASE DISCLAIMER

  1. Shall not be responsible for and shall not pay for the following Installation or start-up.
  2. Service by an unauthorized service provider;
  3. Damage or repair due to service by an unauthorized service provider or use of unauthorized parts.
  4. Damage caused by accidents, abuse, alteration, misuse, installation that is not in accordance with the instructions contained in the User Manual, or local codes.
  5. To correct normal adjustments or settings, due to improper installation, commissioning or local gas supply properties.
  6. Shipping and handling costs, export duties, or installation cost.
  7. The cost of service calls to diagnose trouble; or Removal or re-installation cost.