Installation Instructions and Owner’s Manual
PWS1 Series
Water Softener Systems
Pre-installation Instructions
Description of the softener
The softener system includes a mineral tank (with gravel, distributor and
softener resin), brine tank (with salt shelf, brine well, brine tank lid and
safety brine valve), and a meter initiated electronic backwashing control
valve with bypass and brine line.
Successful Application
Softeners are designed to remove hardness minerals (calcium and magnesium)
from water by the process of ion exchange. They may also remove small amounts
of “clear water” iron (2 ppm or less). Softeners are not designed to remove
“red water” iron or bacterial iron. If greater levels of iron, “red water” or
iron bacteria are present, an iron filter must precede the softener. Softeners
are not designed to remove particulates. If there is any sediment or turbidity
present in the water, a backwashing filter with appropriate media must precede
the softener. Only specialty tannin softeners are designed to remove tannins
and the yellow to tea color from water. Softeners will not reduce hydrogen
sulfide (“rotten egg” odor).
Time of Regeneration
Periodically the control valve will go through regeneration. Regeneration is
factory preset to 2:00 A.M. The time of regeneration may be changed if needed
(see programming procedures on pages 10-11).
Location Considerations
The proper location to install the softener will ensure optimum performance
and satisfactory water quality. The following factors should be considered in
selecting the location of this system.
- The softener must be installed after the pressure tank (private well system only).
- The softener should be installed after any iron filter and/or other backwashing filter.
- If chlorine is present in the supply water a whole house carbon filter should be installed before the softener.
- The system must not be subject to freezing temperatures
- Ensure that any in-line filter installed prior to the softener does not restrict the flow or pressure required to backwash the softener.
- The system should be installed as close as possible (preferably within 15’) to an adequate floor or laundry drain capable of handling the backwash cycle volume and flow rate (refer to unit specifications on pages 12 – 13). An air gap should be provided between the drain line and plumbing drain.
- All water conditioning equipment should be installed at least 10’ prior to the water heater. Water temperatures exceeding 100°F can damage the internal components of the control valve and mineral tank. An expansion tank may need to be installed in the line to the water heater in order to allow for thermal expansion and comply with local plumbing codes.
- Appliances requiring extended periods of continuous or high flow water use (i.e. geothermal heat pumps, swimming pools, lawn irrigation, outside hose bibs, etc.) should bypass all water conditioning equipment unless the equipment has been specifically designed for that purpose.
General Installation Instructions
GENERAL INSTALLATION & SERVICE WARNINGS
The softener is not designed to support the weight of plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone
anywhere. A silicone lubricant may be used on black “O” Rings, but is not
necessary. Avoid any type of lubricants, including silicone, on red or clear
lip seals.
Do not use pipe dope or other sealants on threads. Teflon® tape must be used
on the threads of the 1″ NPT inlet and outlet and on the threads for the drain
line connection. Teflon® tape is not used on the nut connections or caps
because “O” Ring seals are used.
The nuts and caps are designed to be unscrewed or tightened by hand or with
the special plastic Service Wrench, (CV3193, not included). If necessary,
pliers can be used to unscrew the nut or cap. Do not use a pipe wrench to
tighten nuts or caps. Do not place screwdriver in slots on caps and/or tap
with a hammer.
NOTE: If the plumbing system is used as the ground leg of the electric
supply, continuity should be maintained by installing ground straps around any
non-conductive plastic piping or bypass used in the installation.
Make sure the softener is not installed backwards. The softener will not
function properly if installed backwards and softener resin may be forced into
the water lines. Arrows molded into the valve body indicate the direction of
flow.
Site Requirements
- water pressure — 25-100 psi (1.7 – 6.9 bar)
- water temperature — 33-100°F (0.5-37.7°C)
- electrical — 115/120 V, 60 Hz uninterrupted outlet dry locations only
- the tank should be on a firm level surface
Typical Installation
Detailed Installation Instructions
STEP 1:| Carefully remove all components from packaging. DO NOT DISCARD
PACKAGING until all water softener components and fittings have been located.
---|---
STEP 2:| Using the integrated coupling nuts, attach the bypass valve to
the inlet/outlet of the control valve and put handles in the bypass position
(Figure 2).
STEP 3:| Place unit at desired installation position.
STEP 4:| Shut off water at main supply. Relieve pressure by opening
nearest faucet. On private well systems, turn off power to pump and drain
pressure tank. SHUT OFF POWER OR FUEL SUPPLY TO WATER HEATER.
STEP 5:| Cut main supply line as required to fit plumbing to inlet and
outlet of bypass valve. DO NOT PLUMB INLET AND OUTLET BACKWARDS. Piping
should be supported. Do not apply heat to any fitting attached to the bypass
or control valve.
STEP 6:| Use the provided polyethylene tubing (NO VINYL TUBING) to run
drain line from control valve drain fitting (Figure 2) to floor drain or sump
pit capable of handling the backwash rate of the softener (refer to
specifications on Page 12 – 13). THE DISCHARGE END OF THE DRAIN LINE MUST BE
FIRMLY SECURED! There must be an air gap at the end of the drain line to
prevent siphoning of wastewater and meet plumbing code. Total length of drain
line should be 15’ or less. AVOID OVERHEAD DRAINS.
STEP 7:
Connect one end of the 3/8” brine line to the control valve quick connect
brine refill elbow (Figure 2, Page 5). Insert the other end of the brine line
through the hole in the brine tank and into the quick connect fitting on the
top of the safety brine valve (Figure 3). Remove the quick connect collet
retainer clip (if included) before inserting the brine line into each fitting,
press the tube in very firmly and replace the retainer clip behind the collet.
NOTE: THE BRINE TUBING SHOULD BE INSERTED 5/8” INTO THE FITTING. DO NOT
PUT SALT INTO THE BRINE TANK AT THIS TIME. STEP 8:
If desired, install overflow tubing (not provided) from overflow elbow on
brine tank (Figure 3) to floor drain. Tubing must be lower than the overflow
elbow at all times. DO NOT CONNECT DRAIN LINE FROM SOFTENER CONTROL VALVE TO
BRINE TANK OVERFLOW. DO NOT CONNECT BRINE TANK DRAIN LINE TO THE SOFTENER
DRAIN LINE.
STEP 9:
Plug the transformer into an un-switched electrical outlet. Ensure the control
valve is in “Service” mode (display will alternate between time, gallons
remaining, days remaining and flow rate).
STEP 10:
Place the bypass valve in the “Service” position (refer to Figure 4a, Page 8)
and open main supply valve or turn on power to pump on private well systems.
Allow the unit to fill with water and pressurize, then place the bypass valve
in the “Bypass” position.
STEP 11:
Add water in the brine tank to slightly above the top level of the salt grid
(approx. 5 – 6 gallons for units without a salt grid). DO NOT ADD SALT TO THE
BRINE TANK AT THIS TIME.
STEP 12:
With the bypass valve in the “Bypass” position (refer to Figure 4a, Page
8), press and hold the REGEN button until the motor starts. Then use the REGEN
button to advance the control valve to the BACKWASH cycle to release pressure
and purge air from the mineral tank.
STEP 13:
Refer to Figure 4, Page 8 for bypass valve operation. Rotate the INLET knob of
the bypass valve slowly to the “Service” position (Figure 4a). If any air
spurts or any softener resin is expelled to the drain, stop turning the knob
until only water flows to the drain, then continue turning the knob fully to
the “Service” position.
STEP 14:
When all air has been purged from the system and only water is running to the
drain, turn the OUTLET knob of the bypass valve to the “Service” position
also. Allow the system to backwash for a few minutes or until the drain water
runs clear.
STEP 15:
Using the REGEN button, advance the control valve to the REGENERANT DRAW DN
(downflow brine draw) cycle. Verify that the water level in the brine tank is
slowly dropping (less than ½ gpm). Allow water level to drop below the top of
the salt grid before continuing. If the water level does not drop, refer to
page 21 for Troubleshooting. After verifying water level is dropping, use the
REGEN button to advance past the BACKWASH 2, RINSE AND 5 second FILL cycle to
the normal service display.
ADD SALT TO BRINE TANK NOW. Any type of water softener salt may be used.
STEP 16:
Check for leaks and correct as necessary.
STEP 17:
Turn power or fuel supply back on to water heater.
STEP 18:
Press and hold the NEXT and UP buttons together until the screen changes to
input the adjusted hardness level water (refer to Installer Settings, Page 10,
for details), then press NEXT repeatedly until the time of day is displayed.
STEP 19:
Press the CLOCK button to set the current time of day. (Page 10, note AM and
PM).
Bypass Valve
The bypass valve is used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1″ full flow bypass valve incorporates four positions including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building. Be sure to install bypass valve onto main control valve, before beginning plumbing or make provisions in the plumbing system for a bypass. The bypass body and rotors are glass filled Noryl® and the nuts and caps are glass filled polypropylene. All seals are self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal “O” Rings can easily be replaced if service is required. The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles. The handles identify the direction of flow. The plug valves enable the bypass valve to operate in four positions.
-
Normal Operation Position: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener or filter. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig. 4a).
-
Bypass Position: The inlet and outlet handles point to the center of the bypass. The system is isolated from the water pressure in the plumbing system. Untreated water is supplied to the building (Fig. 4b).
-
Diagnostic Position: The inlet handle points toward the control valve and the outlet handle points to the center of bypass valve. Untreated supply water is allowed to flow to the system and to the building, while not allowing water to exit from the system to the building (Fig. 4c) . This allows the service technician to draw brine and perform other tests without the test water going to the building.
NOTE: The system must be run through a rinse cycle before returning the bypass valve to the normal position. -
Shut Off Position: The inlet handle points to the center of the bypass valve and the outlet handle points away from the control valve. The water is shut off to the building. The water treatment system will depressurize upon opening a tap in the building. A negative pressure in the building combined with the softener being in regeneration could cause a siphoning of brine into the building. If water is available on the outlet side of the softener it is an indication of water bypassing the system (Fig. 4d)
General Operation
USER DISPLAYS
When the system is operating, one of several displays may be shown. Pressing
NEXT will alternate between the displays. One of the displays is the current
time of day. The second display shows days to a regen/gallons remaining. Days
To A Regen is the number of days left before the system goes through a
regeneration cycle. Capacity remaining is the number of gallons that will be
treated before the system goes through a regeneration cycle. The third display
is current flow in gal/min. The user can scroll between the displays as
desired by pushing NEXT or display will scroll automatically. When water is
being treated (i.e. water is flowing through the system) the word “GPM”
flashes on left side of display when other than flow rate is displayed. User
screens will continuously scroll, switching views every 3 seconds. If the
screens are manually scrolled, this screen will remain constant for 5 minutes
then continue to scroll. The conditional screens will take precedence over the
scrolling and the conditional conditions will apply. To manually reduce
capacity, press down button while capacity remaining or days to a regen is
displayed. MANUAL REGENERATION
Sometimes there is a need to regenerate the system sooner than when the system
calls for it, usually referred to as manual regeneration. There may be a
period of heavy water usage because of guests or a heavy laundry day. To
initiate a manual regeneration at the preset delayed regeneration time, press
and release “REGEN”. The words “REGEN TODAY” will flash in left corner of
display as it scrolls through displays to indicate that the system will
regenerate at the preset delayed regeneration time. If you pressed the “REGEN”
button in error, pressing the button again will cancel the request. To
initiate a manual regeneration immediately, press and hold the “REGEN” button
for five seconds. The system will begin to regenerate immediately. The request
cannot be cancelled. You must cycle all the way through the cycles to make it
stop. PLEASE NOTE: This will reset the meter. Note: If the salt tank does not
contain salt, fill with salt and wait at least two hours before regenerating.
If two regenerations are desired within 24 hour period, press /release REGEN
button. REGEN TODAY will flash on screen. Press and hold REGEN button until
valve initiates an immediate regeneration.
Installer Settings
A) SET THE TIME OF DAY
-
Press the “CLOCK” button
a. The upper left of the display will show “TIME HOUR”
b. The lower left of the display will show “SET”
c. The hour and AM or PM will flash -
Press the UP or DOWN buttons (triangle pointing up or down) until the correct combination of hour and “AM” or “PM” is reached to match the current time.
-
Press the “NEXT” button
a. The upper left of the display will show “TIME MINUTES”
b. The lower left of the display will show “SET”
c. The minutes will flash -
Press the UP or DOWN buttons until the minutes match the current time. If you need to go back to the HOUR screen press the “REGEN” button.
-
Press the “NEXT” button to return to the main screen.
Power Loss – Lithium battery on circuit board provides up to 2 years of
time clock backup during power outages. If the power is out when battery is
depleted, only time of day needs to be reset, all other values are stored in
non-volatile memory. When time of day is flashing, replace lithium coin type
2032 battery. Battery back-up feature will be activated after 24 hours of
power.
B) Enter Programming: The manufacturer has preset the unit so gallons
between regenerations are automatically calculated after hardness is entered.
-
Hardness: Press “NEXT” and UP (triangle pointing up) buttons simultaneously for 3 seconds.
a. The upper left of the display will show “WATER HARDNESS”
b. The lower left of the display will show “SET”
c. A number will flash (default 20) followed by “GR” (grains). -
Based on water analysis results (obtained either from a lab or in-field testing). Set the amount of hardness in grains per gallon using the UP or DOWN (triangle pointing up or down) buttons. The allowable range is from 1 to 150 in 1 grain increments.
Note: Increase the grains per gallon if soluble (“clear water”) iron and/or manganese is present (1 ppm iron = 3 gpg hardness and 1 ppm manganese = 5 gpg hardness). -
Regeneration Days Override: Press the “NEXT” button
a. The upper left of the display will show “DAYS BETWEEN REGEN”
b. The lower left of the display will show “SET”
c. A number will flash (default 14) -
Using the UP or DOWN (triangle pointing up or down) buttons, set the maximum number of days (default 14, recommended) the softener will go without initiating regeneration even if the unit still has capacity remaining based on water usage, hardness setting and capacity setting. The allowable range is 1 to 28 and OFF. If set to OFF, the unit will only regenerate based on water usage, hardness and capacity.
-
Regeneration Time: Press the “NEXT” button
a. The upper left of the display will show “REGEN TIME HOUR”
b. The lower left of the display will show “SET”
c. The hour and AM or PM will flash -
Regeneration Hour: Using the UP or DOWN buttons, set the combination of hour of day and “AM” or “PM” that the BACKWASH cycle of regeneration should occur. Please note that regeneration will actually begin with the short (less than 10 minutes) Brine Fill cycle 90 minutes prior to the time set here followed by 90 minutes (default) of inactivity to allow water in the brine tank to become saturated with salt.
-
Press the “NEXT” button
a. The upper left of the display will show “REGEN TIME MINUTES”
b. The lower left of the display will show “SET”
c. The minutes will flash -
Regeneration Minutes: Using the UP or DOWN buttons, set the minutes portion of the time when regeneration should occur. If you need to go back to the HOUR screen press the “REGEN” Button.
-
Energy Saver: Using the UP or DOWN buttons, set the mode of operation for
Energy Saver; OFF, ON or AUTO. Unless set to OFF the display will dim when not actively using the buttons. -
Exit Programming: Press the “NEXT” button
a. The upper left of the display will show “TIME”
b. The current time of day will be shown on the right side of the display
c. Only the colon between the hour and minutes will be flashing
Specifications
Description | Two Tank Models |
---|---|
PWS1-30 | PWS1-45 |
MEDIA VOLUME ft 3 | 1.0 |
3.0
CAPACITY, grains| | | | |
@Factory Salt @ 9lb/ft3| 24,000| 36,000| 48,000| 60,000|
72,000
@Max. Salt @ 15lb/ft3| 30,000| 45,000| 60,000| 75,000|
90,000
Operating Flow Rate, gpm| | | | |
Continuous (3 gpm/ft3)| 3| 5| 5| 8| 9
Service (8 gpm/ft3, <= 15 psi drop)| 8| 12| 14| 18|
19
Peak (Max. 20 psi drop)| 18| 18| 23| 22| 23
Pressure Loss psi| | | | |
@ Continuous Flow Rate| 2| 4| 2| 5| 5
@ Service Flow Rate| 7| 11| 9| 14| 15
@ Peak Flow Rate| 19| 19| 20| 19| 20
Regen. Flow Rates, gpm| | | | |
Backwash & Rapid Rinse| 2.2| 2.7| 3.2| 4.2| 5.3
Injector| Blue| Blue| Blue| Yellow| Orange
Brine Draw / Rinse| 0.38 / 0.5| 0.38 / 0.5|
0.38 / 0.5| 0.43 / 0.64| 0.60 / 1.05
Service Pipe Size, in.| 1” & 3/4”| 1” &
3/4”| 1” & 3/4”| 1” & 3/4”| 1” &
3/4”
Factory Regeneration Settings| | | | |
Brine Tank Fill (lbs of salt)| 9| 13.5| 18| 22.5| 27
Softening (minutes dissolving salt)| 90| 90| 90| 90|
90
Backwash (minutes)| 6| 7| 7| 8| 8
Brine Draw & Rinse (minutes)| 45| 60| 70| 80| 65
Backwash 2 (minutes)| 1| 1| 1| 1| 1
Rapid Rinse (minutes)| 5| 7| 6| 7| 7
Total Water Used, gallons| 48| 69| 78|
114| 145
Dimensions in.| | | | |
Mineral Tank, diameter x height| 9 x 48| 10 x 54|
12 x 48| 13 x 54| 14 x 65
Brine Tank, diameter x height| 18 x 33| 18 x 33|
18 x 33| 18 x 33| 23 x 42
Overall, depth x width x height| 18 x 27 x 56| 18
x 28 x 62| 18 x 30 x 56| 18 x
31 x 62| 23 x 37 x 76
Approximate Ship Wt., lbs.| 104| 137| 162|
213| 284
Description| Space Saver Model| Cabinet Models
---|---|---
PWS1C30| PWS1CC30| PWS1CC40
Resin Volume, cu. ft.| 1.0| 1.0| 1.3
Capacity, grains| | |
@Factory Salt @ 9lb/ft3| 24,000| 24,000| 32,000
@Max. Salt @ 15lb/ft3| 30,000| 30,000| 39,000
Gravel Underbed, lbs.| 20| 20| 20
Operating Flow Rate, gpm| | |
Continuous (3 gpm/ft3)| 3| 3| 4
Service (8 gpm/ft3, <= 15 psi drop| 8| 8| 10
Peak (Max. 20 psi drop)| 22| 22| 19
Pressure Loss psi (kPa)| | |
@ Continuous Flow Rate| 2| 2| 1
@ Service Flow Rate| 5| 5| 3
@ Peak Flow Rate| 20| 20| 19
Regen. Flow Rates, gpm| | |
Backwash & Rapid Rinse| 2.7| 2.7| 2.7
Injector| Blue| Blue| Blue
Brine Draw and Rinse| 0.38 / 0.5| 0.38 / 0.5|
0.38 / 0.5
Service Pipe Size, in.| 1” & 3/4”| 1” &
3/4”| 1” & 3/4”
Factory Regeneration Settings| | |
Brine Tank Fill (lbs of salt)| 9| 9| 12
Softening (minutes dissolving salt)| 90| 90| 90
Backwash (minutes)| 5| 5| 6
Brine Draw & Rinse (minutes)| 45| 45| 55
Backwash 2 (minutes)| 1| 1| 1
Rapid Rinse (minutes)| 4| 4| 6
Total Water Used,gallons| 48| 48| 61
Dimensions in.| | |
Mineral Tank, diameter x height| 10 x 35| 10 x 35|
10 x 44
Brine Tank, w x d x h| 12 x 12 x 34| -NA-| -NA-
Overall, length x width x height| 16 x 23 x 43| 12
x 24 x 45| 12 x 24 x 50
Approximate Ship Wt., lbs.| 94| 105| 135
Description| High Efficiency Model Numbers
---|---
PWS1C30-HE
(Space Saver)| PWS1-30-HE| PWS1-45-HE| PWS1-60-HE|
PWS1-75-HE| PWS1-90-HE
Media Volume, ft 3| 1.0| 1.0| 1.5| 2.0|
2.5| 3.0
Capacity, grains| | | | | |
@ Factory Salt – 6lb/ft3| 22,000| 22,000| 33,000| 44,000|
55,000| 66,000
@ Max. Salt – 15lb/ft3| 31,000| 31,000| 46,500| 62,000|
93,000| 93,000
Operating Flow Rate, gpm| | | | | |
Continuous (3 gpm / ft3)| 3| 3| 5| 5| 8| 9
Service (8 gpm / ft3, <=15 psi drop)| 8| 8| 12| 14|
18| 19
Peak (Max. 20 psi drop)| 22| 18| 18| 23| 22| 23
Pressure Loss psi| | | | | |
@ Continuous Flow Rate| 2| 2| 4| 2| 5| 5
@ Service Flow Rate| 5| 7| 11| 9| 14| 15
@ Peak Flow Rate| 20| 19| 19| 20| 19| 20
Regen. Flow Rates, gpm| | | | | |
Backwash & Rapid Rinse| 2.7| 2.2| 2.7| 3.2| 4.2|
5.3
Injector| Blue| Blue| Blue| Blue| Yellow| Orange
Brine Draw and Rinse| 0.38 / 0.5| 0.38 / 0.5|
0.38 / 0.5| 0.38 / 0.5| 0.43 / 0.64|
0.60 / 1.05
Service Pipe Size, in.| 1” & 3/4”| 1” &
3/4”| 1” & 3/4”| 1” & 3/4”| 1” &
3/4”| 1” & 3/4”
Factory Regeneration Settings| | | | | |
Brine Tank Fill (lbs of salt)| 6| 6| 9| 12| 15|
18
Softening (minutes dissolving salt)| 90| 90| 90| 90|
90| 90
Backwash (minutes)| 4| 5| 6| 6| 7| 7
Brine Draw & Rinse (minutes)| 35| 40| 55| 60| 70|
55
Backwash 2 (minutes)| 1| 1| 1| 1| 1| 1
Rapid Rinse (minutes)| 4| 4| 5| 5| 5| 5
Total Water Used, gallons| 41| 41| 59|
67| 97| 122
Dimensions in.| | | | | |
Mineral Tank, diameter x height| 10 x 35| 9 x 48|
10 x 54| 12 x 48| 13 x 54| 14 x
65
Brine Tank, diameter x height| 12 x 12 x 34| 18
x 33| 18 x 33| 18 x 33| 18 x
33| 23 x 42
Overall, length x width x height| 16 x 23 x 43| 18
x 27 x 56| 18 x 28 x 62| 18 x
30 x 56| 18 x 31 x 62| 23 x 37
x 76
Approximate Ship Wt., lbs.| 94| 104| 137|
162| 213| 213
Component Parts Breakdown
Component Parts List
REF | DESCRIPTION | MODEL NUMBER |
---|---|---|
PWS1-30 | PWS1-45 | PWS1-60 |
**A*** | Control Valve | PWS1-30-VLV-L-BP- |
PWS1-60-VLV-L-BP- | PWS1-75-VLV-L-BP- | PWS1-90-VLV-L-BP- |
B | Mineral Tank | MTP0948GR |
C | Distributor | D100S-48 |
D | Resin | 2 – H05P |
E | 1/4/ x 1/8 gravel | QC20 |
F | Brine Tank Assy. | BTSQ1833ASSY |
BTSQ1833ASSY | BT2342ASSY | |
G | Overflow Elbow | BT-OVERFLO |
OVERFLO
H| Safety Brine Valve| SBV14ASSY| SBV14ASSY| SBV14ASSY| SBV14ASSY|
SBV23ASSY
I| Salt Platform| BTSG18SQ| BTSG18SQ| BTSG18SQ| BTSG18SQ| BTSG23
J**| Bypass Valve Less Fittings| CV3006| CV3006| CV3006| CV3006| CV3006
K| Elbow Locking Clip| FC103| FC103| FC103| FC103| FC103
REF| DESCRIPTION| MODEL NUMBER
---|---|---
PWS1C30| PWS1CC30| PWS1CC40
**A*| Control Valve| PWS1C30-VLV-L-BP-| PWS1CC30-VLV-L-BP-|
PWS1CC40-VLV-L-BP-
B| Mineral Tank| MTP1035GR| MTP1035GR| MTP1044GR
C| Distributor| D100S-48| D100S-48| D100S-48
D| Resin| 2 – H05P| 2 – H05P| 2.5 – H05P
E| 1/4/ x 1/8 gravel| QC20| QC20| QC20
F| Brine Tank Assy.| BT1234ASSY| BC-1035C| BC-1044C
G| Overflow Elbow| BT-OVERFLO| BT-OVERFLO| BT-OVERFLO
H| Safety Brine Valve| SBV14ASSY| SBV14ASSY| SBV14ASSY
I| Salt Platform| BTSG12| –NA–| –NA–
J**| Bypass Valve Less Fittings| CV3006| CV3006| CV3006
K**| Elbow Locking Clip| FC103| FC103| FC103
REF
|
DESCRIPTION
| MODEL NUMBER
---|---|---
PWS1C30-HE
(Space Saver)| PWS1-30-HE| PWS1-45-HE| PWS1-60-HE|
PWS1-75-HE| PWS1-90-HE
**A*| Control Valve| PWS1C30-HE-VLV-L-BP-| PWS1-30-HE-VLV-L-BP-| PWS1-45
-HE-VLV-L-BP-| PWS1-60-HE-VLV-L-BP-| PWS1-75-HE-VLV-L-BP-| PWS1-90-HE-
VLV-L-BP-
B| Mineral Tank| MTP1035GR| MTP0948GR| MTP1054GR| MTP1248GR| MTP1354N|
MTP1465N
C| Distributor| D100S-48| D100S-48| D100S-54| D100S-48| D100S-54|
D100S-65
D| Resin| 2 – UHE05P| 2 – UHE05P| 3 – UHE05P| 4 – UHE05P| 5 – UHE05P| 6
– UHE05P
E| 1/4/ x 1/8 gravel| QC20| QC20| QC20| QC20| 2 – QC20| QC50
F| Brine Tank Assy.| BT1234ASSY| BTSQ1833ASSY| BTSQ1833ASSY|
BTSQ1833ASSY| BTSQ1833ASSY| BT2342ASSY
G| Overflow Elbow| BT-OVERFLO| BT-OVERFLO| BT-OVERFLO| BT-OVERFLO| BT-
OVERFLO| BT-OVERFLO
H| Safety Brine Valve| SBV14ASSY| SBV14ASSY| SBV14ASSY| SBV14ASSY|
SBV14ASSY| SBV23ASSY
I| Salt Platform| BTSG12| BTSG18| BTSG18| BTSG18| BTSG18| BTSG23
J**| Bypass Valve Less Fittings| CV3006| CV3006| CV3006| CV3006| CV3006|
CV3006
K**| Elbow Locking Clip| FC103| FC103| FC103| FC103| FC103| FC103
*A top screen (18280-02, not shown) is included with the control valve assembly of “-HE” suffix, Cabinet & Space Saver models
**Refer to “Installation Fitting Assemblies” pages 18-19 for available I/O
fittings.
ALL MODELS INCLUDE ¾ QUICK CONNECT FITTINGS AS WELL AS 1” MALE NPT ELBOWS
Control Valve Breakdown
Control Valve Parts List
REF # | Part Number | Description |
---|---|---|
A | CV3002-A | Drive Assembly (does not include circuit board or motor) |
B | CV3186-06 | Power Cord with Transformer, 15 VDC |
C | CV3003 | Meter and Cable Assembly |
D | CV3006 | Bypass Valve, Less Fittings |
1 | CV3998-01FA | Front Cover, PXX1 Series |
2 | CV3107-01 | Drive Motor |
3 | CV3578HP- 02BOARD | Circuit Board, PXX1 Series |
4 | CV3004 | Drive Cap Assembly |
5 | CV3135 | O-ring, -228 |
6 | CV3011 | Piston Assembly |
7 | CV3174 | Brine Valve |
8 | CV3005 | Seal Cartridge Assembly |
9 | CV3946 | Back Plate, PXX1 Series |
10 | CV3180 | Base O-ring, -337 |
11 | CV3105 | O-ring, -215 |
12 | CV3177-01 | Injector Screen |
13 | CV3010-1Z | Plug, Injector Assembly |
14 | CV3010-1F CV3010-1G | |
CV3010-1I | Injector, Dark Blue (all models other than those below) Injector, |
Yellow (PWS1-75, PWS1-75-HE)
Injector, Orange (PWS1-90, PWS1-90-HE)
15| CV3150| Retainer, Split Ring
16| CV3151| Nut, 1” Quick Connect
17| CH4615| Clip, Elbow Locking
18| CV3163| O-ring, -019
19| CV3165-01| Retainer, Brine Refill Flow Control
20| CV4144| 3/8” Elbow, Parker fitting
21| CV3192 PKP10TS8BULK| Compression nut, ¾” FNPT, for drain elbow Insert, for
5/8” OD poly tube
22| CV3158-02| Elbow, Drain, ¾” Male
23| CV3159-01| Retainer, Drain Line Flow Control
24| CV3162-022 CV3162-027 CV3162-032 CV3162-042 CV3162-053| Drain Line Flow
Control Button:
Flow Control Washer, 2.2 GPM (09×48 tanks)
Flow Control Washer, 2.7 GPM (10×35, 10×44, 10×54 tanks) Flow Control Washer,
3.2 GPM (12×48 tanks)
Flow Control Washer, 4.2 GPM (13×54 tanks)
Flow Control Washer, 5.3 GPM (14×65 tanks)
Installation Fitting Assemblies
1″ PVC MALE NPT ELBOW
Ref| Part #| Description| Qty
| CV3007| 1″ PVC male NPT elbow assy| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3149| Fitting| 2
3/4″ & 1″ PVC SOLVENT ELBOW
Ref| Part #| Description| Qty
| CV3007-01| 3/4″ & 1″ PVC solvent elbow assy| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3189| Fitting| 2
1″ BRASS SWEAT
Ref| Part #| Description| Qty
| CV3007-02| 1″ brass sweat assembly| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3188| Fitting| 2
3/4″ BRASS SWEAT
Ref| Part #| Description| Qty
| CV3007-03| 3/4″ brass sweat assembly| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3188-01| Fitting| 2
3/4″ BRASS SHARK BITE
Ref| Part #| Description| Qty
| CV3007-12| 3/4″ brass shark bite assembly| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3628| Fitting| 2
1″ BRASS SHARK BITE
Ref| Part #| Description| Qty
| CV3007-13| 1″ brass shark bite assembly| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3629| Fitting| 2
1-1/4″ PLASTIC MALE NPT
Ref| Part #| Description| Qty
| CV3007-05| 1-1/4″ plastic male NPT assembly| 2
1| CV3151| Nut, 1″ quick connect| 2
2| CV3150| Split ring| 2
3| CV3105| O-ring 215| 2
4| CV3317| Fitting| 2
3/4″ QUICK CONNECT
Ref| Part #| Description| Qty
K| QFNCR4| 3/4″ QUICK CONNECT| 1*
(*2 required)
SERVICE WRENCH – CV3193
Although no tools are necessary to assemble or disassemble the valve, the
Service Wrench, (shown in various positions on the valve) is available to aid
in assembly or disassembly.
Troubleshooting
PROBLEM | CAUSES | SOLUTIONS |
---|---|---|
Brine tank overfills or does not draw brine | A) Brine line not fully inserted |
into fittings
B) Brine line inserted into the brine tank overflow fitting rather than
connected to the safety brine valve
C) Softener drain line connected to brine overflow fitting or overflow drain
line
D) Obstruction in the control valve
E) Problems with drain line: plugged, frozen, kinked, flexible tubing,
overhead installation, diameter too small, longer than 15’
F) Missing BLFC
G) Missing brine stem
H) Worn seals| 1) Tighten nuts at either end of brine line
2) Verify brine line is installed correctly
3) Verify softener drain line is not connected to brine overflow elbow or
brine overflow drain line
4) Check for debris in DLFC Assembly, BLFC Assembly, injector, injector screen
5) Manually put softener into Backwash Cycle (page 9) and unplug the
transformer for 30 minutes to dislodge debris from inside the control valve or
disassemble and clean control valve internal components
6) Resolve issues with the drain line
7) Verify brine line flow control button is not missing
8) Verify piston brine stem is not missing
9) Replace seal and spacer assembly
Hard water or softener not using salt| A) Softener is plugged into an
electrical outlet without power or one that is tied to a switch
B) No salt in the brine tank
C) Salt in the brine tank has “bridged”
D) Bypass Valve is not in “Service” position or is leaking
E) Obstruction in control valve
I) Problems with drain line: ( See letter “E” in prior section )
F) Control valve programmed incorrectly
G) Softener sized improperly for actual service flow rates
H) Faulty or unplugged drive motor
I) Meter cable disconnected| 1) Verify softener has uninterrupted power
2) Fill brine tank with salt
3) Hit the side of the brine tank with rubber mallet to break any bridging
that has formed in the brine tank
4) Verify bypass is in “Service” position (Figure 4a, Page 8)
5) Check for debris in DLFC Assembly, BLFC Assembly, injector, injector screen
6) Manually put softener into Backwash Cycle (page 9) and unplug transformer
for 20-30 minutes to dislodge debris
7) Resolve issues with drain line
8) Review control valve programming
9) Verify actual service flow rates required and compare to system
specifications (pages 12-13)
10) Verify drive motor is connected to control valve circuit board connector
J1 (labeled “MOTOR”)
11) Verify meter cable (grey cable, 3 pins) is connected to control valve
circuit board connector J2 (labeled “METER”)
Softener regenerates at wrong time of day| A) Clock is not set
B) Power outage
C) Incorrect control valve programming| 1) Reset softener clock (pages 9 & 10)
2) Verify control valve programming (pages 10 – 11)
Resin in water lines, plugged aerators| A) Unit is installed backwards
B) Distributor basket is damaged| 1) Re-plumb unit with water supply entering
bypass inlet (page 5)
2) Replace damaged distributor basket
Salty Water| A) Brine tank overfilled
B) Problems with drain line: ( See Letter “E” in Brine Tank Overfill
section )
C) Rinse cycle is short
D) Salt setting too high
E) Distributor tube improperly seated in control valve or is too short
F) Low water pressure| 1) See “Brine tank overfills” section (Page 21)
2) Resolve drain line issues
3) Contact technical support for assistance in verifying \ adjusting Rinse
Cycle length and Salt Setting
4) Verify proper installation of distributor tube
5) Verify at least 25 psi of line pressure
Softener leaks to drain in “Service” position| A) Problem in piston cartridge
assembly
B) Control valve is jammed or halted during regeneration
C) Drive cap assembly is not tightened properly| 1) Replace seals and/or
piston if needed
2) Verify control valve is in “SOFTENING” mode
3) Tighten drive cap assembly
Low water pressure| A) Iron or sediment build up in softener
B) Insufficient pump capacity| 1) Increase backwash frequency by increasing
hardness setting (page 10)
2) Verify at least 25 psi of line pressure
Display is blank| A) Control valve circuit board needs reset
B) Transformer is unpowered, unplugged or defective
C) Defective circuit board| 1) Hold “NEXT” and “REGEN” buttons for 3 seconds
2) Remove battery, unplug power for 5 seconds, plug back in, replace dead
battery
3) Verify transformer is plugged into an electrical outlet that has power and
transformer cable (black, 4 pins) is plugged into control valve connector J4
(labeled “POWER”)
4) With transformer plugged into electrical outlet, use a volt meter to test
the 2 outer pins (furthest left and furthest right) of connector J4 on the
control valve circuit board. Should be approximately 15 volts DC. Replace
transformer if defective.
5) Replace circuit board if needed
“SOFTENING” does not display when water is flowing| A) Bypass valve not in
“Service” position
B) Meter cable disconnected
C) Restricted/stalled meter turbine
D) Defective meter| 1) Verify bypass is in “Service” position (Figure 4a, Page
8)
2) Verify meter cable (grey cable, 3 pins) is connected to control valve
circuit board connector J2 (labeled “METER”)
3) Remove meter and check for restriction
4) Replace meter if needed
Display shows incorrect time-of-day or time-of-day flashes| A) Outlet is on a
switch
B) Power outage
C) Control valve was reset
D) Defective circuit board| 1) Use an un-switched outlet
2) Reset time-of-day
3) Replace circuit board if needed
ERROR CODE:| |
1001 – unable to sense motor movement| A) Drive motor not inserted fully
to engage pinion or is defective
B) Circuit board not properly snapped into drive bracket
C) Center reduction gear reflector dirty| 1) Re-insert motor, check for broken
wires, verify motor plugged into connector J1 (labeled “MOTOR”) on control
valve circuit board and reset control valve (hold “NEXT” and “REGEN” buttons
for 3 seconds)
2) Re-seat circuit board into drive bracket and reset control valve
3) Clean reduction gear reflectors (page 17)
1002 – unexpected motor stall| A) Obstruction in control valve
B) Main drive gear too tight
C) Improper voltage delivered to circuit board| 1) Remove piston and seal
assemblies for inspection and repair or replacement and reset control valve
(hold “NEXT” and “REGEN” buttons for 3 seconds)
2) Loosen main drive gear and reset control vlalve
3) Verify proper voltage is being supplied to circuit board (see Solution 4
under “Display is Blank” section, page 22)
1003 – motor ran too long, cannot find next cycle position| A) Motor
failure during regeneration
B) Obstruction in control valve
C) Drive bracket not snapped in place properly| 1) Re-insert motor, check for
broken wires, verify motor plugged into connector J1 (labeled “MOTOR”) on
control valve circuit board and reset control valve (hold “NEXT” and “REGEN”
buttons for 3 seconds)
2) Remove piston and seal assemblies for inspection and repair or replacement
and reset control valve
3) Re-seat drive bracket assembly and reset control valve
1004 – motor ran too long, timed out trying to reach home position| A)
Drive bracket not snapped in place properly
B) Center reduction gear reflector dirty| 1) Re-seat drive bracket assembly
and reset control valve (hold “NEXT” and “REGEN” buttons for 3 seconds)
2) Clean reduction gear reflectors (page 16)
1006 – MAV/SEPS/ NHBP/AUX MAV
motor ran too long, looking for park position| A) Control valve not programmed
for ALT OFF
B) Obstruction in control valve| 1) Enter cycle programming level and verify
second parameter is set to ALT oFF
2) Remove piston and seal assemblies for inspection and repair or replacement
and reset control valve (hold “NEXT” and “REGEN” buttons for 3 seconds)
1007 – MAV/SEPS/ NHBP/AUX MAV
motor ran too short looking for park position| A) Control valve not programmed
for ALT OFF
B) Obstruction in control valve| 1) Enter cycle programming level and verify
second parameter is set to ALT oFF
2) Remove piston and seal assemblies for inspection and repair or replacement
and reset control valve (hold “NEXT” and “REGEN” buttons for 3 seconds)
TEN YEAR LIMITED WARRANTY
WARRANTY – Franklin Water Treatment, LLC, warrants this water conditioner
against any defects that are due to faulty material or workmanship during the
warranty period.
This warranty does not include damage to the product resulting from accident,
neglect, misuse, misapplication, alteration, installation, or operation
contrary to printed instructions, or damage caused by freezing, fire, flood,
or Acts of God. From the original date of consumer purchase, we will repair or
replace, at our discretion, any part found to be defective within the warranty
period described below. Purchaser is responsible for any shipping cost to our
facility and any local labor charges.
- One year on the entire water conditioner
- Five years on the control valve (except the seal & spacer kit which is a wear & tear component, 1 year)
- Five years on the brine tank (if applicable)
- Ten years on the mineral tank
GENERAL CONDITIONS – Should a defect or malfunction occur, contact the
dealer that you purchased the product from. If you are unable to contact the
dealer, contact Franklin Water Treatment, LLC at (260)693-1972. We will
require a full description of the problem, model number, date of purchase, and
selling dealer’s business name and address.
We assume no warranty liability in connection with this water conditioner
other than specified herein. This warranty is in lieu of all other warranties,
expressed or implied, including warranties of fitness for a particular
purpose. We do not authorize any person or representative to assume for us any
other obligations on the sale of this water conditioner.
FILL IN AND KEEP FOR YOUR RECORDS
Original Purchaser| Date of Purchase| Model #|
---|---|---|---
Address of Original Installation| City| State
Dealer Purchased From| Dealer Address| City| State