DIEHL DN 50.200 Hydrus Ultrasonic Cold and Hot Water Meter Installation Guide

June 4, 2024
DIEHL

DIEHL-LOGO

DIEHL DN 50.200 Hydrus Ultrasonic Cold and Hot Water Meter

DIEHL-DN-50.200-Hydrus-Ultrasonic-Cold-and-Hot-Water-Meter-
PRODUCT

WHAT IS INCLUDE

DIEHL-DN-50.200-Hydrus-Ultrasonic-Cold-and-Hot-Water-Meter-
FIG1

INSTALLATION

DIEHL-DN-50.200-Hydrus-Ultrasonic-Cold-and-Hot-Water-Meter-
FIG2 DIEHL-DN-50.200-Hydrus-
Ultrasonic-Cold-and-Hot-Water-Meter-FIG3 DIEHL-DN-50.200-Hydrus-Ultrasonic-Cold-and-Hot-Water-Meter-
FIG4

CAUTION

DIEHL-DN-50.200-Hydrus-Ultrasonic-Cold-and-Hot-Water-Meter-
FIG5 DIEHL-DN-50.200-Hydrus-
Ultrasonic-Cold-and-Hot-Water-Meter-FIG6

The data generated by the meter can be viewed in the display loop with system information (e.g. flow rate, volume, date, due date, medium temperature). The loops are numbered from 01 to 09. The optical button located on the front panel enables scrolling the display loops. To save battery lifetime, the meter switches automatically to power save mode after 4 minutes of inactivity. The display is awakened again by pressing the optical button. After awakening, the display shows first a screen check (i.e. all symbols in the display are briefly switched on and off) and then the total volume. This remains for at least 10 seconds on the display (also when the optical button is pressed). Afterwards the display loop can be switched with the help of the optical button.

DIEHL-DN-50.200-Hydrus-Ultrasonic-Cold-and-Hot-Water-Meter-
FIG7

Display loop

88| Displaytest| 05| Error / Alarms
01| Total volume| 07| High resolution total volume
02| Battery lifetime| 08| Due date / Due date volume
03| Firmware version / Checksum| 09| Reverse volume
04| Current flow

1 Conformity label 10 Protection class
2 Year of the declaration of con- formity 11 Temperature class
3 Type of examinaiton certificate number 12 Product article number
4 Meter serial number & QR code 13 Communication interfaces
5 Optical button 14 Battery lifetime
6 Positioning assistance for opto head 15 Dynamic range
7 Pressure loss class 16 Nominal diameter
8 Maximum admissible pressure 17 Permanent flow rate
9 Metrological class 18 Type

Pulse outputs (open drain)

Input voltage max. 30 V
Input current max. 27 mA
Voltage drop at the active output max. 2 V / 27 mA
Current through inactive output max. 5 μA / 30 V
Reverse current max. 27 mA
Pulse duration, pulse break, pulse frequency depending on device

configuration (detailed description on request)

Wiring diagram

The pulse outputs are open-drain circuits. The drain branch has a resistance of just 0 ohm, i.e. there is no internal current limiting. If required, this must be provided by an external protective resistance (*if not available on site). The internal resistance of the switching device must be 5x of the protective resistance.

Cable pin assignment
The Radio/L-Bus/Pulse, Pulse/Pulse and M-Bus/Pulse/Pulse versions of the meter are supplied with a 1.5 m 2/3/4/5-wire connecting cable with wire end ferrules.

 | Radio/ L- Bus/ Pulse| Pulse/ Pulse| M- Bus/ Pulse/ Pulse| M- Bus| 4- Wire Pulse
---|---|---|---|---|---
M-Bus|  |  | x| x|
Pulse, Output 1|  | x| x|  | x
Pulse, Output 2| x| x| x|  | x
L-Bus| x|  |

Connection (network name)

GND brown brown brown   brown
Pulse 1 or L-Bus yellow yellow yellow   white
Pulse 2 green green green   yellow
M-Bus 1     white white
M-Bus 2     blue blue
Manipulation / Tampering     green
Number of Wires 3 3 5 2 4

Never connect the external M-Bus to the pulse output of the meter! It will destroy the pulse output and lead to the loss of all factory warranty claims.

Radio specifications

Sending intervals| Every 14 … 256 seconds (variable, according to

0.1 duty cycle (min. 14 seconds); depending on protocol length and programming)

---|---
434 MHz frequency band| Transmission power (EN 300 220-2 V3.2.1):

10 mW e.r.p.

868 MHz frequency band| Transmission power (EN 300 220-2 V3.2.1):

25 mW e.r.p

Venting

In the event that complete venting of the meter is not possible, please install the meter at an angle of 45°!

Open Source Software Notice
This product contains open-source software components. The use and distribution of any open source software is governed by the respective terms and conditions of the applicable open source license. By using this product, you acknowledge that you have reviewed such license terms and notices, and you agree to be obliged by these terms. Please ensure that you get yourself familiar with the terms and conditions of the license before using this product. The complete license terms are available in the DIEHL Metering Download-center: https://www.diehl.com/metering/en/support-center/download- center/ If you have any questions regarding open source software used in this
product, please contact DIEHL Metering support:
[email protected]

EU DECLARATION OF CONFORMITY

This declaration of conformity is issued under the sole responsibility of the manufacturer. The object of the declaration described above is in conformity with the relevant Union harmonisation legislation, insofar as it is applied:

Type Technology No of the EU type examination certificate
173 Ultrasonic Water Meter DE-19-MI001-PTB012 (NB 0102, PTB) T819958N-01-TEC

(NB 0682, CTC)

In conformity with the following relevant harmonised standards or normative documents or other technical specifications:

  • EN 55032:2015/A11:2020
  • EN ISO 4064-1:2017
  • EN ISO 4064-2:2017
  • EN ISO 4064-3:2014
  • EN ISO 4064-5:2017
  • OIML R49-1:2006
  • OIML R49-2:2004
  • EN 62368-1:2014/AC:2015
  • EN 62479:2010
  • EN 300 220-1 v3.1.1
  • EN 300 220-2 v3.1.1
  • EN 300 330 v2.1.1
  • EN 301 489-1 v2.2.3
  • EN 301 489-3 v2.1.1
  • EN 301 489-3 v2.1.2
  • EN 301 489-52 v1.1.0
  • EN 301 908-1 v13.1.1
  • EN 301 908-13 v13.1.1
  • WELMEC 7.2:2018
  • EN IEC 63000:2018

Name and address of the manufacturer| The notified body LNE n° 0071 has carried out the module D certification of quality assurance under number:
---|---
DIEHL METERING

| __

LNE-36769

The contact address marked on the product can be one of the site listed in the module D certificate.
Nürnberg, 2022-05-02 Dr. Christof Bosbach
President of the Division Board
Diehl Metering
Reiner Edel
Member of the Division Board
Finance & Administration

Diehl Metering GmbH
Industriestrasse 13
91522 Ansbach
Phone: +49 981 1806-0
Fax: +49 981 1806-615
[email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DIEHL User Manuals

Related Manuals