Diehl IZAR OH BT2 Reading Head via Bluetooth interface User Guide

June 5, 2024
DIEHL

diehl logo

Metering
IZAR OH BT 2

Diehl IZAR OH BT2 Reading Head via Bluetooth interface User guide

This guide must be given to the end consumer.

General description

The IZAR OPTO HEAD BT 2 (IZAR OH BT 2) is an optical reading head that can be connected to static or mobile computers via a Bluetooth interface. Laptops or PCs can be retrofitted with this interface if necessary using a Bluetooth USB adapter.
The optical interface offers the two standards IrDA and ZVEI, which means all Diehl Metering Group meters with an optical interface can be read and configured. The IZAR  H BT 2 is switched between ZVEI and IrDA by Diehl Metering programs either automatically or must be set in the software according to the interface of the meter to be read.
The IZAR OH BT 2 is equipped with a lithium-ion battery for approx. 14 hours of continuous operation. Charging a completely flat battery takes about 3.5 hours.
The operating statuses are indicated by four colored LEDs. An on/off switch is built into the device for easy operation. The IZAR OH BT also has a metal ring to fasten a  carrying strap.

Operation

Before using the IZAR OH BT 2 for the first time, charge it up with the enclosed USB plug-in standard power supply. The optical reading head should be switched off during charging.
To communicate with a terminal (e.g. an electronic water meter), place the optical reading head on the optical communication interface provided for this purpose, then switch on the reading head. the status LEDs indicate that the IZAR OH BT 2 is ready for operation.
Now use your computer to activate the relevant communication function.
The transmission range is up to 10 meters. If the transmission is poor, turn the reading head slightly and try again.
Switch off the IZAR OH BT 2 when communication is finished to save the battery and increase the operating period of the device.

LED status display

Status LED “Charge”
Charging in progress red LED on
Charging finished green LED on
Status LEDs
Link TX
Flat battery
Initialization after power on

and green LEDs flash several times
Device is ready| | green LED on| green LED on
The Bluetooth link is active| blue LED on| |
Data being sent/received| | red LED flashes| red LED flashes

Technical data

General

Power supply| Lithium-Ion battery 3.7 V / 900 mAh
Bluetooth specification| 2.4 GHz, version 4.0, class 2
Bluetooth range| Up to 10 m
Transmission frequency| 2.4 GHz
Data transmission rate| 2.1 Mbit/s
Optical modes| ZVEI, IrDA
Length| 64 mm
Diameter| 32.5 mm
Weight| 55 g
Environment
Operating temperature range| 0 … 40 °C
Protection class| IP 40

Safety instructions

Any changes or modifications not expressly approved by Diehl Metering GmbH could void the user’s authority to operate the equipment.

FCC Warning
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC  Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user  is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.

Class 1 IRED product
**** IZAR OH BT 2 contains a Class 1 infrared emitting diode (IRED) according to IEC 60825-1. All users should follow the cautionary instructions below; use of the product other than specified here may cause hazardous radiation exposure.

  • Do not stare at the IRED or shine the IRED into your eyes or those of another person.
  • Do not allow young children to use the product without adult supervision.
  • Do not try to replace or repair the IRED; these components are not user-replaceable.
  • Do not shine the IRED on a reflective surface.
  • Do not scratch the lens.
  • Do wipe the lens periodically with a clean, soft cloth.
  • Do contact Diehl Metering customer support if you need technical or other assistance.

Battery
The internal battery is not intended to be removed by unauthorized parties. For servicing, please contact Diehl Metering customer support.

  • Do not place the device in or near a heat source. Excessive heating can damage the device and/or the battery. Exposing this compo- nents to excessive heat for a prolonged period could cause the device or the battery to explode.
  • Do not dry a wet or damp device with an appliance or heat source. Extreme heat sources can adversely affect the internal battery components even though the outside might not appear damaged.
  • Do not store your device in environments with high levels of humidity.
    In the event of an equipment error, discontinue use and contact the responsible customer support immediately.
    An equipment error applies when, for example, the housing and/ or the supply line is damaged.

The equipment may only be operated and charged with an approved power supply. The attached power supply may only be used for voltages indicated on the power supply.  The mains plug is used as a disconnecting device and should remain readily operable.

Always observe the relevant regulations against the electrostatic dis- charge (ESD). Do not open the housing.

Warranty

The manufacturer provides a warranty in accordance with the General Conditions of Delivery and Payment.
The term of the warranty for the battery in the equipment is 6 months.

Transport and storage

When sending wireless measuring instruments/components by air, deactivate the wireless before shipping.

Environmental note

The device must not be disposed of together with the domestic waste.
Hand it over to professional recycling.

Approval and Conformity

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.

FCC ID: 2AO2B-OPTOHEAD2
Contains FCC-ID: RFRMSR IC: 4957A-MSR
Hereby, Diehl Metering declares that the radio equipment type IZAR OH BT 2 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: https://www.diehl.com/metering/en/support-center /download-center/

Diehl Metering GmbH
Industriestrasse 13
91522 Ansbach
Phone: +49 981 1806-0
Fax: +49 981 1806-615
[email protected]www.diehl.com/metering