Product Information

  • Product Name: FR8000-OLS
  • Product Version: Release 2.0.0
  • System Introduction: FR8000-OLS is a new generation optical line system designed for edge data center interconnection, specifically for IPoverDWDM applications.
  • It offers a cost-effective solution that meets the transport capacity demand of more than 4T.

Chassis Specifications:

  • Power Supply: (Optional) 2DC-48V, (Optional) 2AC 220V
  • FAN: 4 units
  • Operation Temperature: 0 ~ 50°C
  • Altitude: 0-10,000ft
  • Humidity: 5% ~ 95% (Non-condensing)
  • Dimension: 430(D)355(W)265(H)nm

Chassis Indicator Instruction:

Indicator Name Description
PWR Rack Power Supply Indicator On: Power Supply in normal, Off: Power

Supply in abnormal
PS_A| DC Power Supply_1 Indicator| On: Power Supply in normal, Off: Power Supply in abnormal
PS_B| AC Power Supply_2 Indicator| On: Power Supply in normal, Off: Power Supply in abnormal
PS_C| AC Power Supply_1 Indicator| On: Power Supply in normal, Off: Power Supply in abnormal
PS_D| AC Power Supply_2 Indicator| On: Power Supply in normal, Off: Power Supply in abnormal

Product Usage Instructions

Login:

  • Initial IP address: 192.168.1.228
  • Default User Name: Admin
  • Password: 1234

System Information:

Parameter Description
System Name Default: None, Read Only
System Location Default: None, Read Only
System Contact Default: None, Read Only
System Description Default: Read Only
System Running Time Default: Read Only, Timer will be reset after power-off
Software Version Default: Read Only

Revision History

Version| Date| Author| Reasons of Change          Section(s)

Affected

---|---|---|---
1.0| 2017/12/04|  | Initial Release                     All
2.0| 2021/05/01|  | General Update                    All

System Introduction

FR8000-OLS is a new generation of the optical line system, apply to edge data center interconnection, particularly for IPoverDWDM applications. Provide a cost-effective and meet the transport capacity demand for more than 4T.

Key Feature

  • Super T-bit Capacity
  • Extra Long Distance -2000km, Without electric repeater transmission capacity.
  • Support 100M to 400G mixed transmission.
  • Smooth network update for high bandwidth.
  • Whole network intelligent protection, high reliability.
  • Line-side Support 1+1 Double port selecting redundancy protection
  • The modular design of Power Supply, Fan Unit, Services Card for easy maintenance.

Various Format

  • 1U/1.25U open and modularized chassis structure.
  • 1/4 universal module slots
  • High-density Mux/Demux

Intelligent Network Management

  • Support SNMP、CLI、WEB、TELNET
  • Completely visual graphic information
  • Support electronic map positioning, fault location and isolation quickly and accurately
  • Support voice alarm, e-mail alerts, SMS alerts approach, real-time online remote monitoring
  • EMS Management platform, covering the entire Process from Plan to maintenance.
  • Support fault quick diagnosis, one-click export resource statements
  • Support Cable Fault point localization diagnosis, real-time detection cable quality.
  • Support OPM transmission performance scan

Chassis specifications

System parameter

|

Description

---|---
Power Supply| (Optional)2DC-48V ,(Optional)2AC 220V
FAN| 4 FAN units
Operation Temperature| 0℃ ~ 50℃
Altitude| 0-10,000ft
Humidity| 5% ~ 95% (Non-condensing)
Dimension| 430(D)
355(W)*265(H)nm

Chassis Indicator Instruction

Indicator

|

Name

|

Description

---|---|---

PWR

|

Rack Power Supply Indicator

| On: Power Supply in normal Off: Power Supply in abnormal

PS_A

|

DC Power Supply_1 Indicator

| On: Power Supply in normal Off: Power Supply in abnormal

PS_B

|

AC Power Supply_2 Indicator

| On: Power Supply in normal Off: Power Supply in abnormal

PS_C

|

AC Power Supply_1 Indicator

| On: Power Supply in normal Off: Power Supply in abnormal

PS_D

|

AC Power Supply_2 Indicator

| On: Power Supply in normal Off: Power Supply in abnormal

Network Management Interface

Loginfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-Optical-Line-
System-FIG-1

Interface Introductionfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-
Optical-Line-System-FIG-2

System – System Informationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-3

Parameter Description Default
System Name   None
System Location   None
System Contact   None
System Description   Read Only
System Running Time System Running Timer¹ Read Only
Software Version Current Version No. Read Only

Notes: 1, Timer will be reset after power-off

System – Reboot Systemfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-
Optical-Line-System-FIG-4

Notes:

  1. Reboot button will reboot the system
  2. Default button will load factory default settings

System – Network Configurationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-5

Parameter Description Default
IP Address   192.168.1.228
SubNet Mask   255.255.255.0
Gateway   192.168.1.1

Notes:

  1. Apply to submit the configuration
  2. Refresh to verify the configuration

System — SNMP Configurationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-6

SNMP Configuration Description Default
Get Community Public/Private Public
Set Community Public/Private Private
Tap Configuration Description Default
--- --- ---
ID 1~5 None
Status Enable/Disable Disable
Version V1 / V2c V2c
Port   162
Community¹   Public
IP Address   0.0.0.0

Notes:

  1. The public community string is viewed as a “read-only” request, permitting the network administrator to view—but not modify—the remote device. The “private” community string is a more powerful option in that it allows the network administrator to “read/write” to the remote system.

System — FTP Configurationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-7

Alarm – Alarm Tablefiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-
Optical-Line-System-FIG-8

System Alarm Log Description Default
No. Item None
yy/mm/dd Date None
hh/mm/ss Time None
Slot M: NMC Slot/01-15: services slot
Alarm Info Check list of Alarm Info None

Note: Download to save the Alarm Log as Excel file into PCfiberroad-
FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-Optical-Line-System-
FIG-9

Panel – Refresh Panel

Check the update card status

Device– Shelf Informationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-10

Chassis Parameters Description Default
Description Chassis Description Read Only
Temperature Real-Time Temperature Detection Read Only
Fan Fan A-B Read Only
Fan Status Normal/Abnormal Read Only
Psu PSU A&B DC power supply Read Only
Type 48V DC Power/AC Power Read Only
Status Normal/Abnormal Read Only

Device– Cards Informationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-11

Slot Description Default

Threshold

| When input power lower than threshold value, PUMP OFF

When output power lower than threshold, EDFA trigger alarm

|

None

Eyesafe Mode|  | OFF

Working Mode

| AGC: Adjustable Gain ±1dB APC: Output adjustable ±1dB|

AGC

 | ACC: Voltage adjustable|
Pump information| Real-time indication| Read Only
Gain| Power Gain Value| Base on parameters
Power| Output Power Value| Read Only

Device – Search Devicesfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-
Optical-Line-System-FIG-12

Note:

  1. Mainly search for a neighbour, apply for remote/neighbour discovery, monitoring.

User – User Managementfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-
Optical-Line-System-FIG-13

User Account Configuration Description Default
User Name Total 2 account admin
Password   1234
Confirm Password   1234
Delete As Needed None

Utility – Date Managementfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-14

Date Management Description Default
Time Set As needed None

Utility – Serial Informationfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-
Interface-Optical-Line-System-FIG-15

Serial Information Description Default
Baud Rate 115200 Read Only
Data Bits 8 Read Only
Parity None Read Only
Stop Bits 1 Read Only
Flow Control None Read Only

Utility – HTTP Portfiberroad-FR8000-OLS-FR8000-OLS-WEB-GUI-Interface-
Optical-Line-System-FIG-16

Note:

  1. Take effect after restarting the system
  • Fiberroad may make changes at any time to the products or specifications contained herein without notice Fiberroad is trademarks of Fiberroad technology Co.,Ltd.©2021 Fiberroad technologu co.,ltd All right reserved

  • Copyright©2021 Fiberroad Technology Co., Ltd. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, be it electronically, mechanically, or by any other means such as photocopying, recording or otherwise, without the prior written permission of Fiberroad Technology Co., Ltd. (Fiberroad)
    Information provided by Fiberroad is believed to be accurate and reliable. However, no responsibility is assumed by Fiberroad for its use nor for any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent rights of Fiberroad.

  • The information contained in this publication is subject to change without notice.

Trademarks

  • Fiberroad’s trademarks have been identified as such. However, the presence or absence of such identification does not affect the legal status of any brand.
  • Units of Measurement
  • Units of measurement in this publication conform to SI standards and practices.
  • May 01, 2021
  • Version number: 2.0.0

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals